iio: ad_sigma_delta: use unsigned long for timeout
authorNicholas Mc Guire <hofrat@osadl.org>
Mon, 23 Jul 2018 09:18:38 +0000 (11:18 +0200)
committerJonathan Cameron <Jonathan.Cameron@huawei.com>
Sat, 28 Jul 2018 11:15:03 +0000 (12:15 +0100)
wait_for_completion_timeout returns unsigned long not int so an appropriate
variable is declared and the assignment and check fixed up.

Signed-off-by: Nicholas Mc Guire <hofrat@osadl.org>
Reviewed-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
drivers/iio/adc/ad_sigma_delta.c

index cf1b048..fc95107 100644 (file)
@@ -209,6 +209,7 @@ static int ad_sd_calibrate(struct ad_sigma_delta *sigma_delta,
        unsigned int mode, unsigned int channel)
 {
        int ret;
+       unsigned long timeout;
 
        ret = ad_sigma_delta_set_channel(sigma_delta, channel);
        if (ret)
@@ -224,8 +225,8 @@ static int ad_sd_calibrate(struct ad_sigma_delta *sigma_delta,
 
        sigma_delta->irq_dis = false;
        enable_irq(sigma_delta->spi->irq);
-       ret = wait_for_completion_timeout(&sigma_delta->completion, 2*HZ);
-       if (ret == 0) {
+       timeout = wait_for_completion_timeout(&sigma_delta->completion, 2 * HZ);
+       if (timeout == 0) {
                sigma_delta->irq_dis = true;
                disable_irq_nosync(sigma_delta->spi->irq);
                ret = -EIO;