hwmon: (lm75) Fix write operations for negative temperatures
authorGuenter Roeck <linux@roeck-us.net>
Thu, 8 Aug 2019 19:00:18 +0000 (12:00 -0700)
committerGuenter Roeck <linux@roeck-us.net>
Sat, 31 Aug 2019 15:04:57 +0000 (08:04 -0700)
Writes into limit registers fail if the temperature written is negative.
The regmap write operation checks the value range, regmap_write accepts
an unsigned int as parameter, and the temperature value passed to
regmap_write is kept in a variable declared as long. Negative values
are converted large unsigned integers, which fails the range check.
Fix by type casting the temperature to u16 when calling regmap_write().

Cc: Iker Perez del Palomar Sustatxa <iker.perez@codethink.co.uk>
Fixes: e65365fed87f ("hwmon: (lm75) Convert to use regmap")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
drivers/hwmon/lm75.c

index ce5ec40..cbabab7 100644 (file)
@@ -154,7 +154,7 @@ static int lm75_write(struct device *dev, enum hwmon_sensor_types type,
        temp = DIV_ROUND_CLOSEST(temp  << (resolution - 8),
                                 1000) << (16 - resolution);
 
-       return regmap_write(data->regmap, reg, temp);
+       return regmap_write(data->regmap, reg, (u16)temp);
 }
 
 static umode_t lm75_is_visible(const void *data, enum hwmon_sensor_types type,