scsi: megaraid_sas: Increase timeout by 1 sec for non-RAID fastpath IOs
authorShivasharan S <shivasharan.srikanteshwara@broadcom.com>
Fri, 6 Apr 2018 09:02:11 +0000 (02:02 -0700)
committerMartin K. Petersen <martin.petersen@oracle.com>
Wed, 18 Apr 2018 23:33:59 +0000 (19:33 -0400)
Hardware could time out Fastpath IOs one second earlier than the timeout
provided by the host.

For non-RAID devices, driver provides timeout value based on OS provided
timeout value. Under certain scenarios, if the OS provides a timeout
value of 1 second, due to above behavior hardware will timeout
immediately.

Increase timeout value for non-RAID fastpath IOs by 1 second.

Signed-off-by: Shivasharan S <shivasharan.srikanteshwara@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
drivers/scsi/megaraid/megaraid_sas_fusion.c

index 0f4d303..358d42d 100644 (file)
@@ -2980,6 +2980,9 @@ megasas_build_syspd_fusion(struct megasas_instance *instance,
                pRAID_Context->timeout_value = cpu_to_le16(os_timeout_value);
                pRAID_Context->virtual_disk_tgt_id = cpu_to_le16(device_id);
        } else {
+               if (os_timeout_value)
+                       os_timeout_value++;
+
                /* system pd Fast Path */
                io_request->Function = MPI2_FUNCTION_SCSI_IO_REQUEST;
                timeout_limit = (scmd->device->type == TYPE_DISK) ?