1 // SPDX-License-Identifier: GPL-2.0
2 /*
3  *  linux/drivers/thermal/cpu_cooling.c
4  *
5  *  Copyright (C) 2012  Samsung Electronics Co., Ltd(http://www.samsung.com)
6  *
7  *  Copyright (C) 2012-2018 Linaro Limited.
8  *
9  *  Authors:    Amit Daniel <amit.kachhap@linaro.org>
10  *              Viresh Kumar <viresh.kumar@linaro.org>
11  *
12  */
13 #include <linux/module.h>
14 #include <linux/thermal.h>
15 #include <linux/cpufreq.h>
16 #include <linux/err.h>
17 #include <linux/idr.h>
18 #include <linux/pm_opp.h>
19 #include <linux/slab.h>
20 #include <linux/cpu.h>
21 #include <linux/cpu_cooling.h>
22
23 #include <trace/events/thermal.h>
24
25 /*
26  * Cooling state <-> CPUFreq frequency
27  *
28  * Cooling states are translated to frequencies throughout this driver and this
29  * is the relation between them.
30  *
31  * Highest cooling state corresponds to lowest possible frequency.
32  *
33  * i.e.
34  *      level 0 --> 1st Max Freq
35  *      level 1 --> 2nd Max Freq
36  *      ...
37  */
38
39 /**
40  * struct freq_table - frequency table along with power entries
41  * @frequency:  frequency in KHz
42  * @power:      power in mW
43  *
44  * This structure is built when the cooling device registers and helps
45  * in translating frequency to power and vice versa.
46  */
47 struct freq_table {
48         u32 frequency;
49         u32 power;
50 };
51
52 /**
53  * struct time_in_idle - Idle time stats
54  * @time: previous reading of the absolute time that this cpu was idle
55  * @timestamp: wall time of the last invocation of get_cpu_idle_time_us()
56  */
57 struct time_in_idle {
58         u64 time;
59         u64 timestamp;
60 };
61
62 /**
63  * struct cpufreq_cooling_device - data for cooling device with cpufreq
64  * @id: unique integer value corresponding to each cpufreq_cooling_device
65  *      registered.
66  * @last_load: load measured by the latest call to cpufreq_get_requested_power()
67  * @cpufreq_state: integer value representing the current state of cpufreq
68  *      cooling devices.
69  * @clipped_freq: integer value representing the absolute value of the clipped
70  *      frequency.
71  * @max_level: maximum cooling level. One less than total number of valid
72  *      cpufreq frequencies.
73  * @freq_table: Freq table in descending order of frequencies
74  * @cdev: thermal_cooling_device pointer to keep track of the
75  *      registered cooling device.
76  * @policy: cpufreq policy.
77  * @node: list_head to link all cpufreq_cooling_device together.
78  * @idle_time: idle time stats
79  *
80  * This structure is required for keeping information of each registered
81  * cpufreq_cooling_device.
82  */
83 struct cpufreq_cooling_device {
84         int id;
85         u32 last_load;
86         unsigned int cpufreq_state;
87         unsigned int clipped_freq;
88         unsigned int max_level;
89         struct freq_table *freq_table;  /* In descending order */
90         struct cpufreq_policy *policy;
91         struct list_head node;
92         struct time_in_idle *idle_time;
93 };
94
95 static DEFINE_IDA(cpufreq_ida);
96 static DEFINE_MUTEX(cooling_list_lock);
97 static LIST_HEAD(cpufreq_cdev_list);
98
99 /* Below code defines functions to be used for cpufreq as cooling device */
100
101 /**
102  * get_level: Find the level for a particular frequency
103  * @cpufreq_cdev: cpufreq_cdev for which the property is required
104  * @freq: Frequency
105  *
106  * Return: level corresponding to the frequency.
107  */
108 static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
109                                unsigned int freq)
110 {
111         struct freq_table *freq_table = cpufreq_cdev->freq_table;
112         unsigned long level;
113
114         for (level = 1; level <= cpufreq_cdev->max_level; level++)
115                 if (freq > freq_table[level].frequency)
116                         break;
117
118         return level - 1;
119 }
120
121 /**
122  * cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
123  * @nb: struct notifier_block * with callback info.
124  * @event: value showing cpufreq event for which this function invoked.
125  * @data: callback-specific data
126  *
127  * Callback to hijack the notification on cpufreq policy transition.
128  * Every time there is a change in policy, we will intercept and
129  * update the cpufreq policy with thermal constraints.
130  *
131  * Return: 0 (success)
132  */
133 static int cpufreq_thermal_notifier(struct notifier_block *nb,
134                                     unsigned long event, void *data)
135 {
136         struct cpufreq_policy *policy = data;
137         unsigned long clipped_freq;
138         struct cpufreq_cooling_device *cpufreq_cdev;
139
140         if (event != CPUFREQ_ADJUST)
141                 return NOTIFY_DONE;
142
143         mutex_lock(&cooling_list_lock);
144         list_for_each_entry(cpufreq_cdev, &cpufreq_cdev_list, node) {
145                 /*
146                  * A new copy of the policy is sent to the notifier and can't
147                  * compare that directly.
148                  */
149                 if (policy->cpu != cpufreq_cdev->policy->cpu)
150                         continue;
151
152                 /*
153                  * policy->max is the maximum allowed frequency defined by user
154                  * and clipped_freq is the maximum that thermal constraints
155                  * allow.
156                  *
157                  * If clipped_freq is lower than policy->max, then we need to
158                  * readjust policy->max.
159                  *
160                  * But, if clipped_freq is greater than policy->max, we don't
161                  * need to do anything.
162                  */
163                 clipped_freq = cpufreq_cdev->clipped_freq;
164
165                 if (policy->max > clipped_freq)
166                         cpufreq_verify_within_limits(policy, 0, clipped_freq);
167                 break;
168         }
169         mutex_unlock(&cooling_list_lock);
170
171         return NOTIFY_OK;
172 }
173
174 /**
175  * update_freq_table() - Update the freq table with power numbers
176  * @cpufreq_cdev:       the cpufreq cooling device in which to update the table
177  * @capacitance: dynamic power coefficient for these cpus
178  *
179  * Update the freq table with power numbers.  This table will be used in
180  * cpu_power_to_freq() and cpu_freq_to_power() to convert between power and
181  * frequency efficiently.  Power is stored in mW, frequency in KHz.  The
182  * resulting table is in descending order.
183  *
184  * Return: 0 on success, -EINVAL if there are no OPPs for any CPUs,
185  * or -ENOMEM if we run out of memory.
186  */
187 static int update_freq_table(struct cpufreq_cooling_device *cpufreq_cdev,
188                              u32 capacitance)
189 {
190         struct freq_table *freq_table = cpufreq_cdev->freq_table;
191         struct dev_pm_opp *opp;
192         struct device *dev = NULL;
193         int num_opps = 0, cpu = cpufreq_cdev->policy->cpu, i;
194
195         dev = get_cpu_device(cpu);
196         if (unlikely(!dev)) {
197                 pr_warn("No cpu device for cpu %d\n", cpu);
198                 return -ENODEV;
199         }
200
201         num_opps = dev_pm_opp_get_opp_count(dev);
202         if (num_opps < 0)
203                 return num_opps;
204
205         /*
206          * The cpufreq table is also built from the OPP table and so the count
207          * should match.
208          */
209         if (num_opps != cpufreq_cdev->max_level + 1) {
210                 dev_warn(dev, "Number of OPPs not matching with max_levels\n");
211                 return -EINVAL;
212         }
213
214         for (i = 0; i <= cpufreq_cdev->max_level; i++) {
215                 unsigned long freq = freq_table[i].frequency * 1000;
216                 u32 freq_mhz = freq_table[i].frequency / 1000;
217                 u64 power;
218                 u32 voltage_mv;
219
220                 /*
221                  * Find ceil frequency as 'freq' may be slightly lower than OPP
222                  * freq due to truncation while converting to kHz.
223                  */
224                 opp = dev_pm_opp_find_freq_ceil(dev, &freq);
225                 if (IS_ERR(opp)) {
226                         dev_err(dev, "failed to get opp for %lu frequency\n",
227                                 freq);
228                         return -EINVAL;
229                 }
230
231                 voltage_mv = dev_pm_opp_get_voltage(opp) / 1000;
232                 dev_pm_opp_put(opp);
233
234                 /*
235                  * Do the multiplication with MHz and millivolt so as
236                  * to not overflow.
237                  */
238                 power = (u64)capacitance * freq_mhz * voltage_mv * voltage_mv;
239                 do_div(power, 1000000000);
240
241                 /* power is stored in mW */
242                 freq_table[i].power = power;
243         }
244
245         return 0;
246 }
247
248 static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_cdev,
249                              u32 freq)
250 {
251         int i;
252         struct freq_table *freq_table = cpufreq_cdev->freq_table;
253
254         for (i = 1; i <= cpufreq_cdev->max_level; i++)
255                 if (freq > freq_table[i].frequency)
256                         break;
257
258         return freq_table[i - 1].power;
259 }
260
261 static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev,
262                              u32 power)
263 {
264         int i;
265         struct freq_table *freq_table = cpufreq_cdev->freq_table;
266
267         for (i = 1; i <= cpufreq_cdev->max_level; i++)
268                 if (power > freq_table[i].power)
269                         break;
270
271         return freq_table[i - 1].frequency;
272 }
273
274 /**
275  * get_load() - get load for a cpu since last updated
276  * @cpufreq_cdev:       &struct cpufreq_cooling_device for this cpu
277  * @cpu:        cpu number
278  * @cpu_idx:    index of the cpu in time_in_idle*
279  *
280  * Return: The average load of cpu @cpu in percentage since this
281  * function was last called.
282  */
283 static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu,
284                     int cpu_idx)
285 {
286         u32 load;
287         u64 now, now_idle, delta_time, delta_idle;
288         struct time_in_idle *idle_time = &cpufreq_cdev->idle_time[cpu_idx];
289
290         now_idle = get_cpu_idle_time(cpu, &now, 0);
291         delta_idle = now_idle - idle_time->time;
292         delta_time = now - idle_time->timestamp;
293
294         if (delta_time <= delta_idle)
295                 load = 0;
296         else
297                 load = div64_u64(100 * (delta_time - delta_idle), delta_time);
298
299         idle_time->time = now_idle;
300         idle_time->timestamp = now;
301
302         return load;
303 }
304
305 /**
306  * get_dynamic_power() - calculate the dynamic power
307  * @cpufreq_cdev:       &cpufreq_cooling_device for this cdev
308  * @freq:       current frequency
309  *
310  * Return: the dynamic power consumed by the cpus described by
311  * @cpufreq_cdev.
312  */
313 static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
314                              unsigned long freq)
315 {
316         u32 raw_cpu_power;
317
318         raw_cpu_power = cpu_freq_to_power(cpufreq_cdev, freq);
319         return (raw_cpu_power * cpufreq_cdev->last_load) / 100;
320 }
321
322 /* cpufreq cooling device callback functions are defined below */
323
324 /**
325  * cpufreq_get_max_state - callback function to get the max cooling state.
326  * @cdev: thermal cooling device pointer.
327  * @state: fill this variable with the max cooling state.
328  *
329  * Callback for the thermal cooling device to return the cpufreq
330  * max cooling state.
331  *
332  * Return: 0 on success, an error code otherwise.
333  */
334 static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
335                                  unsigned long *state)
336 {
337         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
338
339         *state = cpufreq_cdev->max_level;
340         return 0;
341 }
342
343 /**
344  * cpufreq_get_cur_state - callback function to get the current cooling state.
345  * @cdev: thermal cooling device pointer.
346  * @state: fill this variable with the current cooling state.
347  *
348  * Callback for the thermal cooling device to return the cpufreq
349  * current cooling state.
350  *
351  * Return: 0 on success, an error code otherwise.
352  */
353 static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
354                                  unsigned long *state)
355 {
356         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
357
358         *state = cpufreq_cdev->cpufreq_state;
359
360         return 0;
361 }
362
363 /**
364  * cpufreq_set_cur_state - callback function to set the current cooling state.
365  * @cdev: thermal cooling device pointer.
366  * @state: set this variable to the current cooling state.
367  *
368  * Callback for the thermal cooling device to change the cpufreq
369  * current cooling state.
370  *
371  * Return: 0 on success, an error code otherwise.
372  */
373 static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
374                                  unsigned long state)
375 {
376         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
377         unsigned int clip_freq;
378
379         /* Request state should be less than max_level */
380         if (WARN_ON(state > cpufreq_cdev->max_level))
381                 return -EINVAL;
382
383         /* Check if the old cooling action is same as new cooling action */
384         if (cpufreq_cdev->cpufreq_state == state)
385                 return 0;
386
387         clip_freq = cpufreq_cdev->freq_table[state].frequency;
388         cpufreq_cdev->cpufreq_state = state;
389         cpufreq_cdev->clipped_freq = clip_freq;
390
391         cpufreq_update_policy(cpufreq_cdev->policy->cpu);
392
393         return 0;
394 }
395
396 /**
397  * cpufreq_get_requested_power() - get the current power
398  * @cdev:       &thermal_cooling_device pointer
399  * @tz:         a valid thermal zone device pointer
400  * @power:      pointer in which to store the resulting power
401  *
402  * Calculate the current power consumption of the cpus in milliwatts
403  * and store it in @power.  This function should actually calculate
404  * the requested power, but it's hard to get the frequency that
405  * cpufreq would have assigned if there were no thermal limits.
406  * Instead, we calculate the current power on the assumption that the
407  * immediate future will look like the immediate past.
408  *
409  * We use the current frequency and the average load since this
410  * function was last called.  In reality, there could have been
411  * multiple opps since this function was last called and that affects
412  * the load calculation.  While it's not perfectly accurate, this
413  * simplification is good enough and works.  REVISIT this, as more
414  * complex code may be needed if experiments show that it's not
415  * accurate enough.
416  *
417  * Return: 0 on success, -E* if getting the static power failed.
418  */
419 static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev,
420                                        struct thermal_zone_device *tz,
421                                        u32 *power)
422 {
423         unsigned long freq;
424         int i = 0, cpu;
425         u32 total_load = 0;
426         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
427         struct cpufreq_policy *policy = cpufreq_cdev->policy;
428         u32 *load_cpu = NULL;
429
430         freq = cpufreq_quick_get(policy->cpu);
431
432         if (trace_thermal_power_cpu_get_power_enabled()) {
433                 u32 ncpus = cpumask_weight(policy->related_cpus);
434
435                 load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL);
436         }
437
438         for_each_cpu(cpu, policy->related_cpus) {
439                 u32 load;
440
441                 if (cpu_online(cpu))
442                         load = get_load(cpufreq_cdev, cpu, i);
443                 else
444                         load = 0;
445
446                 total_load += load;
447                 if (load_cpu)
448                         load_cpu[i] = load;
449
450                 i++;
451         }
452
453         cpufreq_cdev->last_load = total_load;
454
455         *power = get_dynamic_power(cpufreq_cdev, freq);
456
457         if (load_cpu) {
458                 trace_thermal_power_cpu_get_power(policy->related_cpus, freq,
459                                                   load_cpu, i, *power);
460
461                 kfree(load_cpu);
462         }
463
464         return 0;
465 }
466
467 /**
468  * cpufreq_state2power() - convert a cpu cdev state to power consumed
469  * @cdev:       &thermal_cooling_device pointer
470  * @tz:         a valid thermal zone device pointer
471  * @state:      cooling device state to be converted
472  * @power:      pointer in which to store the resulting power
473  *
474  * Convert cooling device state @state into power consumption in
475  * milliwatts assuming 100% load.  Store the calculated power in
476  * @power.
477  *
478  * Return: 0 on success, -EINVAL if the cooling device state could not
479  * be converted into a frequency or other -E* if there was an error
480  * when calculating the static power.
481  */
482 static int cpufreq_state2power(struct thermal_cooling_device *cdev,
483                                struct thermal_zone_device *tz,
484                                unsigned long state, u32 *power)
485 {
486         unsigned int freq, num_cpus;
487         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
488
489         /* Request state should be less than max_level */
490         if (WARN_ON(state > cpufreq_cdev->max_level))
491                 return -EINVAL;
492
493         num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus);
494
495         freq = cpufreq_cdev->freq_table[state].frequency;
496         *power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus;
497
498         return 0;
499 }
500
501 /**
502  * cpufreq_power2state() - convert power to a cooling device state
503  * @cdev:       &thermal_cooling_device pointer
504  * @tz:         a valid thermal zone device pointer
505  * @power:      power in milliwatts to be converted
506  * @state:      pointer in which to store the resulting state
507  *
508  * Calculate a cooling device state for the cpus described by @cdev
509  * that would allow them to consume at most @power mW and store it in
510  * @state.  Note that this calculation depends on external factors
511  * such as the cpu load or the current static power.  Calling this
512  * function with the same power as input can yield different cooling
513  * device states depending on those external factors.
514  *
515  * Return: 0 on success, -ENODEV if no cpus are online or -EINVAL if
516  * the calculated frequency could not be converted to a valid state.
517  * The latter should not happen unless the frequencies available to
518  * cpufreq have changed since the initialization of the cpu cooling
519  * device.
520  */
521 static int cpufreq_power2state(struct thermal_cooling_device *cdev,
522                                struct thermal_zone_device *tz, u32 power,
523                                unsigned long *state)
524 {
525         unsigned int target_freq;
526         u32 last_load, normalised_power;
527         struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
528         struct cpufreq_policy *policy = cpufreq_cdev->policy;
529
530         last_load = cpufreq_cdev->last_load ?: 1;
531         normalised_power = (power * 100) / last_load;
532         target_freq = cpu_power_to_freq(cpufreq_cdev, normalised_power);
533
534         *state = get_level(cpufreq_cdev, target_freq);
535         trace_thermal_power_cpu_limit(policy->related_cpus, target_freq, *state,
536                                       power);
537         return 0;
538 }
539
540 /* Bind cpufreq callbacks to thermal cooling device ops */
541
542 static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
543         .get_max_state = cpufreq_get_max_state,
544         .get_cur_state = cpufreq_get_cur_state,
545         .set_cur_state = cpufreq_set_cur_state,
546 };
547
548 static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = {
549         .get_max_state          = cpufreq_get_max_state,
550         .get_cur_state          = cpufreq_get_cur_state,
551         .set_cur_state          = cpufreq_set_cur_state,
552         .get_requested_power    = cpufreq_get_requested_power,
553         .state2power            = cpufreq_state2power,
554         .power2state            = cpufreq_power2state,
555 };
556
557 /* Notifier for cpufreq policy change */
558 static struct notifier_block thermal_cpufreq_notifier_block = {
559         .notifier_call = cpufreq_thermal_notifier,
560 };
561
562 static unsigned int find_next_max(struct cpufreq_frequency_table *table,
563                                   unsigned int prev_max)
564 {
565         struct cpufreq_frequency_table *pos;
566         unsigned int max = 0;
567
568         cpufreq_for_each_valid_entry(pos, table) {
569                 if (pos->frequency > max && pos->frequency < prev_max)
570                         max = pos->frequency;
571         }
572
573         return max;
574 }
575
576 /**
577  * __cpufreq_cooling_register - helper function to create cpufreq cooling device
578  * @np: a valid struct device_node to the cooling device device tree node
579  * @policy: cpufreq policy
580  * Normally this should be same as cpufreq policy->related_cpus.
581  * @capacitance: dynamic power coefficient for these cpus
582  *
583  * This interface function registers the cpufreq cooling device with the name
584  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
585  * cooling devices. It also gives the opportunity to link the cooling device
586  * with a device tree node, in order to bind it via the thermal DT code.
587  *
588  * Return: a valid struct thermal_cooling_device pointer on success,
589  * on failure, it returns a corresponding ERR_PTR().
590  */
591 static struct thermal_cooling_device *
592 __cpufreq_cooling_register(struct device_node *np,
593                         struct cpufreq_policy *policy, u32 capacitance)
594 {
595         struct thermal_cooling_device *cdev;
596         struct cpufreq_cooling_device *cpufreq_cdev;
597         char dev_name[THERMAL_NAME_LENGTH];
598         unsigned int freq, i, num_cpus;
599         int ret;
600         struct thermal_cooling_device_ops *cooling_ops;
601         bool first;
602
603         if (IS_ERR_OR_NULL(policy)) {
604                 pr_err("%s: cpufreq policy isn't valid: %p\n", __func__, policy);
605                 return ERR_PTR(-EINVAL);
606         }
607
608         i = cpufreq_table_count_valid_entries(policy);
609         if (!i) {
610                 pr_debug("%s: CPUFreq table not found or has no valid entries\n",
611                          __func__);
612                 return ERR_PTR(-ENODEV);
613         }
614
615         cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL);
616         if (!cpufreq_cdev)
617                 return ERR_PTR(-ENOMEM);
618
619         cpufreq_cdev->policy = policy;
620         num_cpus = cpumask_weight(policy->related_cpus);
621         cpufreq_cdev->idle_time = kcalloc(num_cpus,
622                                          sizeof(*cpufreq_cdev->idle_time),
623                                          GFP_KERNEL);
624         if (!cpufreq_cdev->idle_time) {
625                 cdev = ERR_PTR(-ENOMEM);
626                 goto free_cdev;
627         }
628
629         /* max_level is an index, not a counter */
630         cpufreq_cdev->max_level = i - 1;
631
632         cpufreq_cdev->freq_table = kmalloc_array(i,
633                                         sizeof(*cpufreq_cdev->freq_table),
634                                         GFP_KERNEL);
635         if (!cpufreq_cdev->freq_table) {
636                 cdev = ERR_PTR(-ENOMEM);
637                 goto free_idle_time;
638         }
639
640         ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL);
641         if (ret < 0) {
642                 cdev = ERR_PTR(ret);
643                 goto free_table;
644         }
645         cpufreq_cdev->id = ret;
646
647         snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
648                  cpufreq_cdev->id);
649
650         /* Fill freq-table in descending order of frequencies */
651         for (i = 0, freq = -1; i <= cpufreq_cdev->max_level; i++) {
652                 freq = find_next_max(policy->freq_table, freq);
653                 cpufreq_cdev->freq_table[i].frequency = freq;
654
655                 /* Warn for duplicate entries */
656                 if (!freq)
657                         pr_warn("%s: table has duplicate entries\n", __func__);
658                 else
659                         pr_debug("%s: freq:%u KHz\n", __func__, freq);
660         }
661
662         if (capacitance) {
663                 ret = update_freq_table(cpufreq_cdev, capacitance);
664                 if (ret) {
665                         cdev = ERR_PTR(ret);
666                         goto remove_ida;
667                 }
668
669                 cooling_ops = &cpufreq_power_cooling_ops;
670         } else {
671                 cooling_ops = &cpufreq_cooling_ops;
672         }
673
674         cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev,
675                                                   cooling_ops);
676         if (IS_ERR(cdev))
677                 goto remove_ida;
678
679         cpufreq_cdev->clipped_freq = cpufreq_cdev->freq_table[0].frequency;
680
681         mutex_lock(&cooling_list_lock);
682         /* Register the notifier for first cpufreq cooling device */
683         first = list_empty(&cpufreq_cdev_list);
684         list_add(&cpufreq_cdev->node, &cpufreq_cdev_list);
685         mutex_unlock(&cooling_list_lock);
686
687         if (first)
688                 cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
689                                           CPUFREQ_POLICY_NOTIFIER);
690
691         return cdev;
692
693 remove_ida:
694         ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
695 free_table:
696         kfree(cpufreq_cdev->freq_table);
697 free_idle_time:
698         kfree(cpufreq_cdev->idle_time);
699 free_cdev:
700         kfree(cpufreq_cdev);
701         return cdev;
702 }
703
704 /**
705  * cpufreq_cooling_register - function to create cpufreq cooling device.
706  * @policy: cpufreq policy
707  *
708  * This interface function registers the cpufreq cooling device with the name
709  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
710  * cooling devices.
711  *
712  * Return: a valid struct thermal_cooling_device pointer on success,
713  * on failure, it returns a corresponding ERR_PTR().
714  */
715 struct thermal_cooling_device *
716 cpufreq_cooling_register(struct cpufreq_policy *policy)
717 {
718         return __cpufreq_cooling_register(NULL, policy, 0);
719 }
720 EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
721
722 /**
723  * of_cpufreq_cooling_register - function to create cpufreq cooling device.
724  * @policy: cpufreq policy
725  *
726  * This interface function registers the cpufreq cooling device with the name
727  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
728  * cooling devices. Using this API, the cpufreq cooling device will be
729  * linked to the device tree node provided.
730  *
731  * Using this function, the cooling device will implement the power
732  * extensions by using a simple cpu power model.  The cpus must have
733  * registered their OPPs using the OPP library.
734  *
735  * It also takes into account, if property present in policy CPU node, the
736  * static power consumed by the cpu.
737  *
738  * Return: a valid struct thermal_cooling_device pointer on success,
739  * and NULL on failure.
740  */
741 struct thermal_cooling_device *
742 of_cpufreq_cooling_register(struct cpufreq_policy *policy)
743 {
744         struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
745         struct thermal_cooling_device *cdev = NULL;
746         u32 capacitance = 0;
747
748         if (!np) {
749                 pr_err("cpu_cooling: OF node not available for cpu%d\n",
750                        policy->cpu);
751                 return NULL;
752         }
753
754         if (of_find_property(np, "#cooling-cells", NULL)) {
755                 of_property_read_u32(np, "dynamic-power-coefficient",
756                                      &capacitance);
757
758                 cdev = __cpufreq_cooling_register(np, policy, capacitance);
759                 if (IS_ERR(cdev)) {
760                         pr_err("cpu_cooling: cpu%d failed to register as cooling device: %ld\n",
761                                policy->cpu, PTR_ERR(cdev));
762                         cdev = NULL;
763                 }
764         }
765
766         of_node_put(np);
767         return cdev;
768 }
769 EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
770
771 /**
772  * cpufreq_cooling_unregister - function to remove cpufreq cooling device.
773  * @cdev: thermal cooling device pointer.
774  *
775  * This interface function unregisters the "thermal-cpufreq-%x" cooling device.
776  */
777 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
778 {
779         struct cpufreq_cooling_device *cpufreq_cdev;
780         bool last;
781
782         if (!cdev)
783                 return;
784
785         cpufreq_cdev = cdev->devdata;
786
787         mutex_lock(&cooling_list_lock);
788         list_del(&cpufreq_cdev->node);
789         /* Unregister the notifier for the last cpufreq cooling device */
790         last = list_empty(&cpufreq_cdev_list);
791         mutex_unlock(&cooling_list_lock);
792
793         if (last)
794                 cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
795                                             CPUFREQ_POLICY_NOTIFIER);
796
797         thermal_cooling_device_unregister(cdev);
798         ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
799         kfree(cpufreq_cdev->idle_time);
800         kfree(cpufreq_cdev->freq_table);
801         kfree(cpufreq_cdev);