drm/amdgpu: check number of gfx ring before init cp gfx
[linux-2.6-microblaze.git] / drivers / acpi / processor_thermal.c
1 // SPDX-License-Identifier: GPL-2.0-or-later
2 /*
3  * processor_thermal.c - Passive cooling submodule of the ACPI processor driver
4  *
5  *  Copyright (C) 2001, 2002 Andy Grover <andrew.grover@intel.com>
6  *  Copyright (C) 2001, 2002 Paul Diefenbaugh <paul.s.diefenbaugh@intel.com>
7  *  Copyright (C) 2004       Dominik Brodowski <linux@brodo.de>
8  *  Copyright (C) 2004  Anil S Keshavamurthy <anil.s.keshavamurthy@intel.com>
9  *                      - Added processor hotplug support
10  */
11
12 #include <linux/kernel.h>
13 #include <linux/module.h>
14 #include <linux/init.h>
15 #include <linux/cpufreq.h>
16 #include <linux/acpi.h>
17 #include <acpi/processor.h>
18 #include <linux/uaccess.h>
19
20 #define PREFIX "ACPI: "
21
22 #define ACPI_PROCESSOR_CLASS            "processor"
23
24 #ifdef CONFIG_CPU_FREQ
25
26 /* If a passive cooling situation is detected, primarily CPUfreq is used, as it
27  * offers (in most cases) voltage scaling in addition to frequency scaling, and
28  * thus a cubic (instead of linear) reduction of energy. Also, we allow for
29  * _any_ cpufreq driver and not only the acpi-cpufreq driver.
30  */
31
32 #define CPUFREQ_THERMAL_MIN_STEP 0
33 #define CPUFREQ_THERMAL_MAX_STEP 3
34
35 static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg);
36
37 #define reduction_pctg(cpu) \
38         per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu))
39
40 /*
41  * Emulate "per package data" using per cpu data (which should really be
42  * provided elsewhere)
43  *
44  * Note we can lose a CPU on cpu hotunplug, in this case we forget the state
45  * temporarily. Fortunately that's not a big issue here (I hope)
46  */
47 static int phys_package_first_cpu(int cpu)
48 {
49         int i;
50         int id = topology_physical_package_id(cpu);
51
52         for_each_online_cpu(i)
53                 if (topology_physical_package_id(i) == id)
54                         return i;
55         return 0;
56 }
57
58 static int cpu_has_cpufreq(unsigned int cpu)
59 {
60         struct cpufreq_policy policy;
61         if (!acpi_processor_cpufreq_init || cpufreq_get_policy(&policy, cpu))
62                 return 0;
63         return 1;
64 }
65
66 static int cpufreq_get_max_state(unsigned int cpu)
67 {
68         if (!cpu_has_cpufreq(cpu))
69                 return 0;
70
71         return CPUFREQ_THERMAL_MAX_STEP;
72 }
73
74 static int cpufreq_get_cur_state(unsigned int cpu)
75 {
76         if (!cpu_has_cpufreq(cpu))
77                 return 0;
78
79         return reduction_pctg(cpu);
80 }
81
82 static int cpufreq_set_cur_state(unsigned int cpu, int state)
83 {
84         struct cpufreq_policy *policy;
85         struct acpi_processor *pr;
86         unsigned long max_freq;
87         int i, ret;
88
89         if (!cpu_has_cpufreq(cpu))
90                 return 0;
91
92         reduction_pctg(cpu) = state;
93
94         /*
95          * Update all the CPUs in the same package because they all
96          * contribute to the temperature and often share the same
97          * frequency.
98          */
99         for_each_online_cpu(i) {
100                 if (topology_physical_package_id(i) !=
101                     topology_physical_package_id(cpu))
102                         continue;
103
104                 pr = per_cpu(processors, i);
105
106                 if (unlikely(!freq_qos_request_active(&pr->thermal_req)))
107                         continue;
108
109                 policy = cpufreq_cpu_get(i);
110                 if (!policy)
111                         return -EINVAL;
112
113                 max_freq = (policy->cpuinfo.max_freq * (100 - reduction_pctg(i) * 20)) / 100;
114
115                 cpufreq_cpu_put(policy);
116
117                 ret = freq_qos_update_request(&pr->thermal_req, max_freq);
118                 if (ret < 0) {
119                         pr_warn("Failed to update thermal freq constraint: CPU%d (%d)\n",
120                                 pr->id, ret);
121                 }
122         }
123         return 0;
124 }
125
126 void acpi_thermal_cpufreq_init(struct cpufreq_policy *policy)
127 {
128         unsigned int cpu;
129
130         for_each_cpu(cpu, policy->related_cpus) {
131                 struct acpi_processor *pr = per_cpu(processors, cpu);
132                 int ret;
133
134                 if (!pr)
135                         continue;
136
137                 ret = freq_qos_add_request(&policy->constraints,
138                                            &pr->thermal_req,
139                                            FREQ_QOS_MAX, INT_MAX);
140                 if (ret < 0)
141                         pr_err("Failed to add freq constraint for CPU%d (%d)\n",
142                                cpu, ret);
143         }
144 }
145
146 void acpi_thermal_cpufreq_exit(struct cpufreq_policy *policy)
147 {
148         unsigned int cpu;
149
150         for_each_cpu(cpu, policy->related_cpus) {
151                 struct acpi_processor *pr = per_cpu(processors, policy->cpu);
152
153                 if (pr)
154                         freq_qos_remove_request(&pr->thermal_req);
155         }
156 }
157 #else                           /* ! CONFIG_CPU_FREQ */
158 static int cpufreq_get_max_state(unsigned int cpu)
159 {
160         return 0;
161 }
162
163 static int cpufreq_get_cur_state(unsigned int cpu)
164 {
165         return 0;
166 }
167
168 static int cpufreq_set_cur_state(unsigned int cpu, int state)
169 {
170         return 0;
171 }
172
173 #endif
174
175 /* thermal cooling device callbacks */
176 static int acpi_processor_max_state(struct acpi_processor *pr)
177 {
178         int max_state = 0;
179
180         /*
181          * There exists four states according to
182          * cpufreq_thermal_reduction_pctg. 0, 1, 2, 3
183          */
184         max_state += cpufreq_get_max_state(pr->id);
185         if (pr->flags.throttling)
186                 max_state += (pr->throttling.state_count -1);
187
188         return max_state;
189 }
190 static int
191 processor_get_max_state(struct thermal_cooling_device *cdev,
192                         unsigned long *state)
193 {
194         struct acpi_device *device = cdev->devdata;
195         struct acpi_processor *pr;
196
197         if (!device)
198                 return -EINVAL;
199
200         pr = acpi_driver_data(device);
201         if (!pr)
202                 return -EINVAL;
203
204         *state = acpi_processor_max_state(pr);
205         return 0;
206 }
207
208 static int
209 processor_get_cur_state(struct thermal_cooling_device *cdev,
210                         unsigned long *cur_state)
211 {
212         struct acpi_device *device = cdev->devdata;
213         struct acpi_processor *pr;
214
215         if (!device)
216                 return -EINVAL;
217
218         pr = acpi_driver_data(device);
219         if (!pr)
220                 return -EINVAL;
221
222         *cur_state = cpufreq_get_cur_state(pr->id);
223         if (pr->flags.throttling)
224                 *cur_state += pr->throttling.state;
225         return 0;
226 }
227
228 static int
229 processor_set_cur_state(struct thermal_cooling_device *cdev,
230                         unsigned long state)
231 {
232         struct acpi_device *device = cdev->devdata;
233         struct acpi_processor *pr;
234         int result = 0;
235         int max_pstate;
236
237         if (!device)
238                 return -EINVAL;
239
240         pr = acpi_driver_data(device);
241         if (!pr)
242                 return -EINVAL;
243
244         max_pstate = cpufreq_get_max_state(pr->id);
245
246         if (state > acpi_processor_max_state(pr))
247                 return -EINVAL;
248
249         if (state <= max_pstate) {
250                 if (pr->flags.throttling && pr->throttling.state)
251                         result = acpi_processor_set_throttling(pr, 0, false);
252                 cpufreq_set_cur_state(pr->id, state);
253         } else {
254                 cpufreq_set_cur_state(pr->id, max_pstate);
255                 result = acpi_processor_set_throttling(pr,
256                                 state - max_pstate, false);
257         }
258         return result;
259 }
260
261 const struct thermal_cooling_device_ops processor_cooling_ops = {
262         .get_max_state = processor_get_max_state,
263         .get_cur_state = processor_get_cur_state,
264         .set_cur_state = processor_set_cur_state,
265 };