Merge branches 'pm-cpufreq', 'pm-sleep' and 'pm-em'
[linux-2.6-microblaze.git] / Documentation / networking / plip.rst
1 .. SPDX-License-Identifier: GPL-2.0
2
3 ================================================
4 PLIP: The Parallel Line Internet Protocol Device
5 ================================================
6
7 Donald Becker (becker@super.org)
8 I.D.A. Supercomputing Research Center, Bowie MD 20715
9
10 At some point T. Thorn will probably contribute text,
11 Tommy Thorn (tthorn@daimi.aau.dk)
12
13 PLIP Introduction
14 -----------------
15
16 This document describes the parallel port packet pusher for Net/LGX.
17 This device interface allows a point-to-point connection between two
18 parallel ports to appear as a IP network interface.
19
20 What is PLIP?
21 =============
22
23 PLIP is Parallel Line IP, that is, the transportation of IP packages
24 over a parallel port. In the case of a PC, the obvious choice is the
25 printer port.  PLIP is a non-standard, but [can use] uses the standard
26 LapLink null-printer cable [can also work in turbo mode, with a PLIP
27 cable]. [The protocol used to pack IP packages, is a simple one
28 initiated by Crynwr.]
29
30 Advantages of PLIP
31 ==================
32
33 It's cheap, it's available everywhere, and it's easy.
34
35 The PLIP cable is all that's needed to connect two Linux boxes, and it
36 can be built for very few bucks.
37
38 Connecting two Linux boxes takes only a second's decision and a few
39 minutes' work, no need to search for a [supported] netcard. This might
40 even be especially important in the case of notebooks, where netcards
41 are not easily available.
42
43 Not requiring a netcard also means that apart from connecting the
44 cables, everything else is software configuration [which in principle
45 could be made very easy.]
46
47 Disadvantages of PLIP
48 =====================
49
50 Doesn't work over a modem, like SLIP and PPP. Limited range, 15 m.
51 Can only be used to connect three (?) Linux boxes. Doesn't connect to
52 an existing Ethernet. Isn't standard (not even de facto standard, like
53 SLIP).
54
55 Performance
56 ===========
57
58 PLIP easily outperforms Ethernet cards....(ups, I was dreaming, but
59 it *is* getting late. EOB)
60
61 PLIP driver details
62 -------------------
63
64 The Linux PLIP driver is an implementation of the original Crynwr protocol,
65 that uses the parallel port subsystem of the kernel in order to properly
66 share parallel ports between PLIP and other services.
67
68 IRQs and trigger timeouts
69 =========================
70
71 When a parallel port used for a PLIP driver has an IRQ configured to it, the
72 PLIP driver is signaled whenever data is sent to it via the cable, such that
73 when no data is available, the driver isn't being used.
74
75 However, on some machines it is hard, if not impossible, to configure an IRQ
76 to a certain parallel port, mainly because it is used by some other device.
77 On these machines, the PLIP driver can be used in IRQ-less mode, where
78 the PLIP driver would constantly poll the parallel port for data waiting,
79 and if such data is available, process it. This mode is less efficient than
80 the IRQ mode, because the driver has to check the parallel port many times
81 per second, even when no data at all is sent. Some rough measurements
82 indicate that there isn't a noticeable performance drop when using IRQ-less
83 mode as compared to IRQ mode as far as the data transfer speed is involved.
84 There is a performance drop on the machine hosting the driver.
85
86 When the PLIP driver is used in IRQ mode, the timeout used for triggering a
87 data transfer (the maximal time the PLIP driver would allow the other side
88 before announcing a timeout, when trying to handshake a transfer of some
89 data) is, by default, 500usec. As IRQ delivery is more or less immediate,
90 this timeout is quite sufficient.
91
92 When in IRQ-less mode, the PLIP driver polls the parallel port HZ times
93 per second (where HZ is typically 100 on most platforms, and 1024 on an
94 Alpha, as of this writing). Between two such polls, there are 10^6/HZ usecs.
95 On an i386, for example, 10^6/100 = 10000usec. It is easy to see that it is
96 quite possible for the trigger timeout to expire between two such polls, as
97 the timeout is only 500usec long. As a result, it is required to change the
98 trigger timeout on the *other* side of a PLIP connection, to about
99 10^6/HZ usecs. If both sides of a PLIP connection are used in IRQ-less mode,
100 this timeout is required on both sides.
101
102 It appears that in practice, the trigger timeout can be shorter than in the
103 above calculation. It isn't an important issue, unless the wire is faulty,
104 in which case a long timeout would stall the machine when, for whatever
105 reason, bits are dropped.
106
107 A utility that can perform this change in Linux is plipconfig, which is part
108 of the net-tools package (its location can be found in the
109 Documentation/Changes file). An example command would be
110 'plipconfig plipX trigger 10000', where plipX is the appropriate
111 PLIP device.
112
113 PLIP hardware interconnection
114 -----------------------------
115
116 PLIP uses several different data transfer methods.  The first (and the
117 only one implemented in the early version of the code) uses a standard
118 printer "null" cable to transfer data four bits at a time using
119 data bit outputs connected to status bit inputs.
120
121 The second data transfer method relies on both machines having
122 bi-directional parallel ports, rather than output-only ``printer``
123 ports.  This allows byte-wide transfers and avoids reconstructing
124 nibbles into bytes, leading to much faster transfers.
125
126 Parallel Transfer Mode 0 Cable
127 ==============================
128
129 The cable for the first transfer mode is a standard
130 printer "null" cable which transfers data four bits at a time using
131 data bit outputs of the first port (machine T) connected to the
132 status bit inputs of the second port (machine R).  There are five
133 status inputs, and they are used as four data inputs and a clock (data
134 strobe) input, arranged so that the data input bits appear as contiguous
135 bits with standard status register implementation.
136
137 A cable that implements this protocol is available commercially as a
138 "Null Printer" or "Turbo Laplink" cable.  It can be constructed with
139 two DB-25 male connectors symmetrically connected as follows::
140
141     STROBE output       1*
142     D0->ERROR   2 - 15          15 - 2
143     D1->SLCT    3 - 13          13 - 3
144     D2->PAPOUT  4 - 12          12 - 4
145     D3->ACK     5 - 10          10 - 5
146     D4->BUSY    6 - 11          11 - 6
147     D5,D6,D7 are   7*, 8*, 9*
148     AUTOFD output 14*
149     INIT   output 16*
150     SLCTIN      17 - 17
151     extra grounds are 18*,19*,20*,21*,22*,23*,24*
152     GROUND      25 - 25
153
154     * Do not connect these pins on either end
155
156 If the cable you are using has a metallic shield it should be
157 connected to the metallic DB-25 shell at one end only.
158
159 Parallel Transfer Mode 1
160 ========================
161
162 The second data transfer method relies on both machines having
163 bi-directional parallel ports, rather than output-only ``printer``
164 ports.  This allows byte-wide transfers, and avoids reconstructing
165 nibbles into bytes.  This cable should not be used on unidirectional
166 ``printer`` (as opposed to ``parallel``) ports or when the machine
167 isn't configured for PLIP, as it will result in output driver
168 conflicts and the (unlikely) possibility of damage.
169
170 The cable for this transfer mode should be constructed as follows::
171
172     STROBE->BUSY 1 - 11
173     D0->D0      2 - 2
174     D1->D1      3 - 3
175     D2->D2      4 - 4
176     D3->D3      5 - 5
177     D4->D4      6 - 6
178     D5->D5      7 - 7
179     D6->D6      8 - 8
180     D7->D7      9 - 9
181     INIT -> ACK  16 - 10
182     AUTOFD->PAPOUT 14 - 12
183     SLCT->SLCTIN 13 - 17
184     GND->ERROR  18 - 15
185     extra grounds are 19*,20*,21*,22*,23*,24*
186     GROUND      25 - 25
187
188     * Do not connect these pins on either end
189
190 Once again, if the cable you are using has a metallic shield it should
191 be connected to the metallic DB-25 shell at one end only.
192
193 PLIP Mode 0 transfer protocol
194 =============================
195
196 The PLIP driver is compatible with the "Crynwr" parallel port transfer
197 standard in Mode 0.  That standard specifies the following protocol::
198
199    send header nibble '0x8'
200    count-low octet
201    count-high octet
202    ... data octets
203    checksum octet
204
205 Each octet is sent as::
206
207         <wait for rx. '0x1?'>   <send 0x10+(octet&0x0F)>
208         <wait for rx. '0x0?'>   <send 0x00+((octet>>4)&0x0F)>
209
210 To start a transfer the transmitting machine outputs a nibble 0x08.
211 That raises the ACK line, triggering an interrupt in the receiving
212 machine.  The receiving machine disables interrupts and raises its own ACK
213 line.
214
215 Restated::
216
217   (OUT is bit 0-4, OUT.j is bit j from OUT. IN likewise)
218   Send_Byte:
219      OUT := low nibble, OUT.4 := 1
220      WAIT FOR IN.4 = 1
221      OUT := high nibble, OUT.4 := 0
222      WAIT FOR IN.4 = 0