1 .. SPDX-License-Identifier: GPL-2.0
2
3 =======================
4 Kernel driver bh1770glc
5 =======================
6
7 Supported chips:
8
9 - ROHM BH1770GLC
10 - OSRAM SFH7770
11
12 Data sheet:
13 Not freely available
14
15 Author:
16 Samu Onkalo <samu.p.onkalo@nokia.com>
17
18 Description
19 -----------
20 BH1770GLC and SFH7770 are combined ambient light and proximity sensors.
21 ALS and proximity parts operates on their own, but they shares common I2C
22 interface and interrupt logic. In principle they can run on their own,
23 but ALS side results are used to estimate reliability of the proximity sensor.
24
25 ALS produces 16 bit lux values. The chip contains interrupt logic to produce
26 low and high threshold interrupts.
27
28 Proximity part contains IR-led driver up to 3 IR leds. The chip measures
29 amount of reflected IR light and produces proximity result. Resolution is
30 8 bit. Driver supports only one channel. Driver uses ALS results to estimate
31 reliability of the proximity results. Thus ALS is always running while
32 proximity detection is needed.
33
34 Driver uses threshold interrupts to avoid need for polling the values.
35 Proximity low interrupt doesn't exists in the chip. This is simulated
36 by using a delayed work. As long as there is proximity threshold above
37 interrupts the delayed work is pushed forward. So, when proximity level goes
38 below the threshold value, there is no interrupt and the delayed work will
39 finally run. This is handled as no proximity indication.
40
41 Chip state is controlled via runtime pm framework when enabled in config.
42
43 Calibscale factor is used to hide differences between the chips. By default
44 value set to neutral state meaning factor of 1.00. To get proper values,
45 calibrated source of light is needed as a reference. Calibscale factor is set
46 so that measurement produces about the expected lux value.
47
48 SYSFS
49 -----
50
51 chip_id
52         RO - shows detected chip type and version
53
54 power_state
55         RW - enable / disable chip
56
57         Uses counting logic
58
59              - 1 enables the chip
60              - 0 disables the chip
61
62 lux0_input
63         RO - measured lux value
64
65              sysfs_notify called when threshold interrupt occurs
66
67 lux0_sensor_range
68         RO - lux0_input max value
69
70 lux0_rate
71         RW - measurement rate in Hz
72
73 lux0_rate_avail
74         RO - supported measurement rates
75
76 lux0_thresh_above_value
77         RW - HI level threshold value
78
79              All results above the value
80              trigs an interrupt. 65535 (i.e. sensor_range) disables the above
81              interrupt.
82
83 lux0_thresh_below_value
84         RW - LO level threshold value
85
86              All results below the value
87              trigs an interrupt. 0 disables the below interrupt.
88
89 lux0_calibscale
90         RW - calibration value
91
92              Set to neutral value by default.
93              Output results are multiplied with calibscale / calibscale_default
94              value.
95
96 lux0_calibscale_default
97         RO - neutral calibration value
98
99 prox0_raw
100         RO - measured proximity value
101
102              sysfs_notify called when threshold interrupt occurs
103
104 prox0_sensor_range
105         RO - prox0_raw max value
106
107 prox0_raw_en
108         RW - enable / disable proximity
109
110              Uses counting logic
111
112              - 1 enables the proximity
113              - 0 disables the proximity
114
115 prox0_thresh_above_count
116         RW - number of proximity interrupts needed before triggering the event
117
118 prox0_rate_above
119         RW - Measurement rate (in Hz) when the level is above threshold
120         i.e. when proximity on has been reported.
121
122 prox0_rate_below
123         RW - Measurement rate (in Hz) when the level is below threshold
124         i.e. when proximity off has been reported.
125
126 prox0_rate_avail
127         RO - Supported proximity measurement rates in Hz
128
129 prox0_thresh_above0_value
130         RW - threshold level which trigs proximity events.
131
132              Filtered by persistence filter (prox0_thresh_above_count)
133
134 prox0_thresh_above1_value
135         RW - threshold level which trigs event immediately