Merge tag 'drm-next-2020-12-24' of git://anongit.freedesktop.org/drm/drm
[linux-2.6-microblaze.git] / Documentation / hwmon / tps40422.rst
1 Kernel driver tps40422
2 ======================
3
4 Supported chips:
5
6   * TI TPS40422
7
8     Prefix: 'tps40422'
9
10     Addresses scanned: -
11
12     Datasheet: https://www.ti.com/lit/gpn/tps40422
13
14 Author: Zhu Laiwen <richard.zhu@nsn.com>
15
16
17 Description
18 -----------
19
20 This driver supports TI TPS40422 Dual-Output or Two-Phase Synchronous Buck
21 Controller with PMBus
22
23 The driver is a client driver to the core PMBus driver.
24 Please see Documentation/hwmon/pmbus.rst for details on PMBus client drivers.
25
26
27 Usage Notes
28 -----------
29
30 This driver does not auto-detect devices. You will have to instantiate the
31 devices explicitly. Please see Documentation/i2c/instantiating-devices.rst for
32 details.
33
34
35 Platform data support
36 ---------------------
37
38 The driver supports standard PMBus driver platform data.
39
40
41 Sysfs entries
42 -------------
43
44 The following attributes are supported.
45
46 ======================= =======================================================
47 in[1-2]_label           "vout[1-2]"
48 in[1-2]_input           Measured voltage. From READ_VOUT register.
49 in[1-2]_alarm           voltage alarm.
50
51 curr[1-2]_input         Measured current. From READ_IOUT register.
52 curr[1-2]_label         "iout[1-2]"
53 curr1_max               Maximum current. From IOUT_OC_WARN_LIMIT register.
54 curr1_crit              Critical maximum current. From IOUT_OC_FAULT_LIMIT
55                         register.
56 curr1_max_alarm         Current high alarm. From IOUT_OC_WARN_LIMIT status.
57 curr1_crit_alarm        Current critical high alarm. From IOUT_OC_FAULT status.
58 curr2_alarm             Current high alarm. From IOUT_OC_WARNING status.
59
60 temp1_input             Measured temperature. From READ_TEMPERATURE_2 register
61                         on page 0.
62 temp1_max               Maximum temperature. From OT_WARN_LIMIT register.
63 temp1_crit              Critical high temperature. From OT_FAULT_LIMIT register.
64 temp1_max_alarm         Chip temperature high alarm. Set by comparing
65                         READ_TEMPERATURE_2 on page 0 with OT_WARN_LIMIT if
66                         TEMP_OT_WARNING status is set.
67 temp1_crit_alarm        Chip temperature critical high alarm. Set by comparing
68                         READ_TEMPERATURE_2 on page 0 with OT_FAULT_LIMIT if
69                         TEMP_OT_FAULT status is set.
70 temp2_input             Measured temperature. From READ_TEMPERATURE_2 register
71                         on page 1.
72 temp2_alarm             Chip temperature alarm on page 1.
73 ======================= =======================================================