clocksource/drivers/sp804: Remove a mismatched comment
authorZhen Lei <thunder.leizhen@huawei.com>
Fri, 18 Sep 2020 13:22:32 +0000 (21:22 +0800)
committerDaniel Lezcano <daniel.lezcano@linaro.org>
Thu, 24 Sep 2020 08:51:04 +0000 (10:51 +0200)
commit2f71078e7753b2fbba62999aa46c2fad16df9d98
tree803cfae1d16c52055c6532456bc9847105a8053c
parent975434f8b24a55af31daa4634972890c061a0a0c
clocksource/drivers/sp804: Remove a mismatched comment

writel(0, base + TIMER_CTRL);
... ...
writel(xxx | TIMER_CTRL_PERIODIC, base + TIMER_CTRL);

The timer is just temporarily disabled, and it will be set to periodic
mode later.

The description of the field TimerMode of the register TimerXControl
as shown below:
0 = Timer module is in free-running mode (default)
1 = Timer module is in periodic mode.

Signed-off-by: Zhen Lei <thunder.leizhen@huawei.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200918132237.3552-5-thunder.leizhen@huawei.com
drivers/clocksource/timer-sp804.c