--- /dev/null
+What: /sys/bus/iio/devices/triggerX/trigger_polarity
+KernelVersion: 4.11
+Contact: fabrice.gasnier@st.com
+Description:
+ The STM32 ADC can be configured to use external trigger sources
+ (e.g. timers, pwm or exti gpio). Then, it can be tuned to start
+ conversions on external trigger by either:
+ - "rising-edge"
+ - "falling-edge"
+ - "both-edges".
+ Reading returns current trigger polarity.
+ Writing value before enabling conversions sets trigger polarity.
+
+What: /sys/bus/iio/devices/triggerX/trigger_polarity_available
+KernelVersion: 4.11
+Contact: fabrice.gasnier@st.com
+Description:
+ List all available trigger_polarity settings.