Merge tag 'for-5.15/io_uring-2021-09-04' of git://git.kernel.dk/linux-block
[linux-2.6-microblaze.git] / Documentation / trace / coresight / coresight-config.rst
1 .. SPDX-License-Identifier: GPL-2.0
2
3 ======================================
4 CoreSight System Configuration Manager
5 ======================================
6
7     :Author:   Mike Leach <mike.leach@linaro.org>
8     :Date:     October 2020
9
10 Introduction
11 ============
12
13 The CoreSight System Configuration manager is an API that allows the
14 programming of the CoreSight system with pre-defined configurations that
15 can then be easily enabled from sysfs or perf.
16
17 Many CoreSight components can be programmed in complex ways - especially ETMs.
18 In addition, components can interact across the CoreSight system, often via
19 the cross trigger components such as CTI and CTM. These system settings can
20 be defined and enabled as named configurations.
21
22
23 Basic Concepts
24 ==============
25
26 This section introduces the basic concepts of a CoreSight system configuration.
27
28
29 Features
30 --------
31
32 A feature is a named set of programming for a CoreSight device. The programming
33 is device dependent, and can be defined in terms of absolute register values,
34 resource usage and parameter values.
35
36 The feature is defined using a descriptor. This descriptor is used to load onto
37 a matching device, either when the feature is loaded into the system, or when the
38 CoreSight device is registered with the configuration manager.
39
40 The load process involves interpreting the descriptor into a set of register
41 accesses in the driver - the resource usage and parameter descriptions
42 translated into appropriate register accesses. This interpretation makes it easy
43 and efficient for the feature to be programmed onto the device when required.
44
45 The feature will not be active on the device until the feature is enabled, and
46 the device itself is enabled. When the device is enabled then enabled features
47 will be programmed into the device hardware.
48
49 A feature is enabled as part of a configuration being enabled on the system.
50
51
52 Parameter Value
53 ~~~~~~~~~~~~~~~
54
55 A parameter value is a named value that may be set by the user prior to the
56 feature being enabled that can adjust the behaviour of the operation programmed
57 by the feature.
58
59 For example, this could be a count value in a programmed operation that repeats
60 at a given rate. When the feature is enabled then the current value of the
61 parameter is used in programming the device.
62
63 The feature descriptor defines a default value for a parameter, which is used
64 if the user does not supply a new value.
65
66 Users can update parameter values using the configfs API for the CoreSight
67 system - which is described below.
68
69 The current value of the parameter is loaded into the device when the feature
70 is enabled on that device.
71
72
73 Configurations
74 --------------
75
76 A configuration defines a set of features that are to be used in a trace
77 session where the configuration is selected. For any trace session only one
78 configuration may be selected.
79
80 The features defined may be on any type of device that is registered
81 to support system configuration. A configuration may select features to be
82 enabled on a class of devices - i.e. any ETMv4, or specific devices, e.g. a
83 specific CTI on the system.
84
85 As with the feature, a descriptor is used to define the configuration.
86 This will define the features that must be enabled as part of the configuration
87 as well as any preset values that can be used to override default parameter
88 values.
89
90
91 Preset Values
92 ~~~~~~~~~~~~~
93
94 Preset values are easily selectable sets of parameter values for the features
95 that the configuration uses. The number of values in a single preset set, equals
96 the sum of parameter values in the features used by the configuration.
97
98 e.g. a configuration consists of 3 features, one has 2 parameters, one has
99 a single parameter, and another has no parameters. A single preset set will
100 therefore have 3 values.
101
102 Presets are optionally defined by the configuration, up to 15 can be defined.
103 If no preset is selected, then the parameter values defined in the feature
104 are used as normal.
105
106
107 Operation
108 ~~~~~~~~~
109
110 The following steps take place in the operation of a configuration.
111
112 1) In this example, the configuration is 'autofdo', which has an
113    associated feature 'strobing' that works on ETMv4 CoreSight Devices.
114
115 2) The configuration is enabled. For example 'perf' may select the
116    configuration as part of its command line::
117
118     perf record -e cs_etm/autofdo/ myapp
119
120    which will enable the 'autofdo' configuration.
121
122 3) perf starts tracing on the system. As each ETMv4 that perf uses for
123    trace is enabled,  the configuration manager will check if the ETMv4
124    has a feature that relates to the currently active configuration.
125    In this case 'strobing' is enabled & programmed into the ETMv4.
126
127 4) When the ETMv4 is disabled, any registers marked as needing to be
128    saved will be read back.
129
130 5) At the end of the perf session, the configuration will be disabled.
131
132
133 Viewing Configurations and Features
134 ===================================
135
136 The set of configurations and features that are currently loaded into the
137 system can be viewed using the configfs API.
138
139 Mount configfs as normal and the 'cs-syscfg' subsystem will appear::
140
141     $ ls /config
142     cs-syscfg  stp-policy
143
144 This has two sub-directories::
145
146     $ cd cs-syscfg/
147     $ ls
148     configurations  features
149
150 The system has the configuration 'autofdo' built in. It may be examined as
151 follows::
152
153     $ cd configurations/
154     $ ls
155     autofdo
156     $ cd autofdo/
157     $ ls
158     description   preset1  preset3  preset5  preset7  preset9
159     feature_refs  preset2  preset4  preset6  preset8
160     $ cat description
161     Setup ETMs with strobing for autofdo
162     $ cat feature_refs
163     strobing
164
165 Each preset declared has a preset<n> subdirectory declared. The values for
166 the preset can be examined::
167
168     $ cat preset1/values
169     strobing.window = 0x1388 strobing.period = 0x2
170     $ cat preset2/values
171     strobing.window = 0x1388 strobing.period = 0x4
172
173 The features referenced by the configuration can be examined in the features
174 directory::
175
176     $ cd ../../features/strobing/
177     $ ls
178     description  matches  nr_params  params
179     $ cat description
180     Generate periodic trace capture windows.
181     parameter 'window': a number of CPU cycles (W)
182     parameter 'period': trace enabled for W cycles every period x W cycles
183     $ cat matches
184     SRC_ETMV4
185     $ cat nr_params
186     2
187
188 Move to the params directory to examine and adjust parameters::
189
190     cd params
191     $ ls
192     period  window
193     $ cd period
194     $ ls
195     value
196     $ cat value
197     0x2710
198     # echo 15000 > value
199     # cat value
200     0x3a98
201
202 Parameters adjusted in this way are reflected in all device instances that have
203 loaded the feature.
204
205
206 Using Configurations in perf
207 ============================
208
209 The configurations loaded into the CoreSight configuration management are
210 also declared in the perf 'cs_etm' event infrastructure so that they can
211 be selected when running trace under perf::
212
213     $ ls /sys/devices/cs_etm
214     configurations  format  perf_event_mux_interval_ms  sinks  type
215     events  nr_addr_filters  power
216
217 Key directories here are 'configurations' - which lists the loaded
218 configurations, and 'events' - a generic perf directory which allows
219 selection on the perf command line.::
220
221     $ ls configurations/
222     autofdo
223     $ cat configurations/autofdo
224     0xa7c3dddd
225
226 As with the sinks entries, this provides a hash of the configuration name.
227 The entry in the 'events' directory uses perfs built in syntax generator
228 to substitute the syntax for the name when evaluating the command::
229
230     $ ls events/
231     autofdo
232     $ cat events/autofdo
233     configid=0xa7c3dddd
234
235 The 'autofdo' configuration may be selected on the perf command line::
236
237     $ perf record -e cs_etm/autofdo/u --per-thread <application>
238
239 A preset to override the current parameter values can also be selected::
240
241     $ perf record -e cs_etm/autofdo,preset=1/u --per-thread <application>
242