From 4d256e4d8ae98ec824f60bcf98e5131e59d08337 Mon Sep 17 00:00:00 2001 From: Jeff Kirsher Date: Wed, 10 Oct 2018 12:16:07 -0700 Subject: [PATCH] Documentation: ixgbe: Prepare documentation for RST conversion Before making the conversion to the RST (reStructured Text) format, there are changes needed to the documentation so that there are no build errors. Also fixed old/broken URLs to the correct or updated URL. Signed-off-by: Jeff Kirsher Tested-by: Andrew Bowers Tested-by: Aaron Brown --- Documentation/networking/ixgbe.txt | 654 ++++++++++++++++++----------- 1 file changed, 416 insertions(+), 238 deletions(-) diff --git a/Documentation/networking/ixgbe.txt b/Documentation/networking/ixgbe.txt index 687835415707..725fc697fd8f 100644 --- a/Documentation/networking/ixgbe.txt +++ b/Documentation/networking/ixgbe.txt @@ -1,349 +1,527 @@ -Linux* Base Driver for the Intel(R) Ethernet 10 Gigabit PCI Express Family of -Adapters +.. SPDX-License-Identifier: GPL-2.0+ + +Linux* Base Driver for the Intel(R) Ethernet 10 Gigabit PCI Express Adapters ============================================================================= Intel 10 Gigabit Linux driver. -Copyright(c) 1999 - 2013 Intel Corporation. +Copyright(c) 1999-2018 Intel Corporation. Contents ======== - Identifying Your Adapter +- Command Line Parameters - Additional Configurations -- Performance Tuning - Known Issues - Support Identifying Your Adapter ======================== +The driver is compatible with devices based on the following: -The driver in this release is compatible with 82598, 82599 and X540-based -Intel Network Connections. - -For more information on how to identify your adapter, go to the Adapter & -Driver ID Guide at: + * Intel(R) Ethernet Controller 82598 + * Intel(R) Ethernet Controller 82599 + * Intel(R) Ethernet Controller X520 + * Intel(R) Ethernet Controller X540 + * Intel(R) Ethernet Controller x550 + * Intel(R) Ethernet Controller X552 + * Intel(R) Ethernet Controller X553 - http://support.intel.com/support/network/sb/CS-012904.htm +For information on how to identify your adapter, and for the latest Intel +network drivers, refer to the Intel Support website: +https://www.intel.com/support SFP+ Devices with Pluggable Optics ---------------------------------- 82599-BASED ADAPTERS +~~~~~~~~~~~~~~~~~~~~ +NOTES: +- If your 82599-based Intel(R) Network Adapter came with Intel optics or is an +Intel(R) Ethernet Server Adapter X520-2, then it only supports Intel optics +and/or the direct attach cables listed below. +- When 82599-based SFP+ devices are connected back to back, they should be set +to the same Speed setting via ethtool. Results may vary if you mix speed +settings. + ++---------------+---------------------------------------+------------------+ +| Supplier | Type | Part Numbers | ++===============+=======================================+==================+ +| SR Modules | ++---------------+---------------------------------------+------------------+ +| Intel | DUAL RATE 1G/10G SFP+ SR (bailed) | FTLX8571D3BCV-IT | ++---------------+---------------------------------------+------------------+ +| Intel | DUAL RATE 1G/10G SFP+ SR (bailed) | AFBR-703SDZ-IN2 | ++---------------+---------------------------------------+------------------+ +| Intel | DUAL RATE 1G/10G SFP+ SR (bailed) | AFBR-703SDDZ-IN1 | ++---------------+---------------------------------------+------------------+ +| LR Modules | ++---------------+---------------------------------------+------------------+ +| Intel | DUAL RATE 1G/10G SFP+ LR (bailed) | FTLX1471D3BCV-IT | ++---------------+---------------------------------------+------------------+ +| Intel | DUAL RATE 1G/10G SFP+ LR (bailed) | AFCT-701SDZ-IN2 | ++---------------+---------------------------------------+------------------+ +| Intel | DUAL RATE 1G/10G SFP+ LR (bailed) | AFCT-701SDDZ-IN1 | ++---------------+---------------------------------------+------------------+ + +The following is a list of 3rd party SFP+ modules that have received some +testing. Not all modules are applicable to all devices. + ++---------------+---------------------------------------+------------------+ +| Supplier | Type | Part Numbers | ++===============+=======================================+==================+ +| Finisar | SFP+ SR bailed, 10g single rate | FTLX8571D3BCL | ++---------------+---------------------------------------+------------------+ +| Avago | SFP+ SR bailed, 10g single rate | AFBR-700SDZ | ++---------------+---------------------------------------+------------------+ +| Finisar | SFP+ LR bailed, 10g single rate | FTLX1471D3BCL | ++---------------+---------------------------------------+------------------+ +| Finisar | DUAL RATE 1G/10G SFP+ SR (No Bail) | FTLX8571D3QCV-IT | ++---------------+---------------------------------------+------------------+ +| Avago | DUAL RATE 1G/10G SFP+ SR (No Bail) | AFBR-703SDZ-IN1 | ++---------------+---------------------------------------+------------------+ +| Finisar | DUAL RATE 1G/10G SFP+ LR (No Bail) | FTLX1471D3QCV-IT | ++---------------+---------------------------------------+------------------+ +| Avago | DUAL RATE 1G/10G SFP+ LR (No Bail) | AFCT-701SDZ-IN1 | ++---------------+---------------------------------------+------------------+ +| Finisar | 1000BASE-T SFP | FCLF8522P2BTL | ++---------------+---------------------------------------+------------------+ +| Avago | 1000BASE-T | ABCU-5710RZ | ++---------------+---------------------------------------+------------------+ +| HP | 1000BASE-SX SFP | 453153-001 | ++---------------+---------------------------------------+------------------+ -NOTES: If your 82599-based Intel(R) Network Adapter came with Intel optics, or -is an Intel(R) Ethernet Server Adapter X520-2, then it only supports Intel -optics and/or the direct attach cables listed below. +82599-based adapters support all passive and active limiting direct attach +cables that comply with SFF-8431 v4.1 and SFF-8472 v10.4 specifications. -When 82599-based SFP+ devices are connected back to back, they should be set to -the same Speed setting via ethtool. Results may vary if you mix speed settings. -82598-based adapters support all passive direct attach cables that comply -with SFF-8431 v4.1 and SFF-8472 v10.4 specifications. Active direct attach -cables are not supported. +Laser turns off for SFP+ when ifconfig ethX down +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ +"ifconfig ethX down" turns off the laser for 82599-based SFP+ fiber adapters. +"ifconfig ethX up" turns on the laser. +Alternatively, you can use "ip link set [down/up] dev ethX" to turn the +laser off and on. + + +82599-based QSFP+ Adapters +~~~~~~~~~~~~~~~~~~~~~~~~~~ +NOTES: +- If your 82599-based Intel(R) Network Adapter came with Intel optics, it only +supports Intel optics. +- 82599-based QSFP+ adapters only support 4x10 Gbps connections. 1x40 Gbps +connections are not supported. QSFP+ link partners must be configured for +4x10 Gbps. +- 82599-based QSFP+ adapters do not support automatic link speed detection. +The link speed must be configured to either 10 Gbps or 1 Gbps to match the link +partners speed capabilities. Incorrect speed configurations will result in +failure to link. +- Intel(R) Ethernet Converged Network Adapter X520-Q1 only supports the optics +and direct attach cables listed below. + ++---------------+---------------------------------------+------------------+ +| Supplier | Type | Part Numbers | ++===============+=======================================+==================+ +| Intel | DUAL RATE 1G/10G QSFP+ SRL (bailed) | E10GQSFPSR | ++---------------+---------------------------------------+------------------+ + +82599-based QSFP+ adapters support all passive and active limiting QSFP+ +direct attach cables that comply with SFF-8436 v4.1 specifications. -Supplier Type Part Numbers +82598-BASED ADAPTERS +~~~~~~~~~~~~~~~~~~~~ +NOTES: +- Intel(r) Ethernet Network Adapters that support removable optical modules +only support their original module type (for example, the Intel(R) 10 Gigabit +SR Dual Port Express Module only supports SR optical modules). If you plug in +a different type of module, the driver will not load. +- Hot Swapping/hot plugging optical modules is not supported. +- Only single speed, 10 gigabit modules are supported. +- LAN on Motherboard (LOMs) may support DA, SR, or LR modules. Other module +types are not supported. Please see your system documentation for details. + +The following is a list of SFP+ modules and direct attach cables that have +received some testing. Not all modules are applicable to all devices. + ++---------------+---------------------------------------+------------------+ +| Supplier | Type | Part Numbers | ++===============+=======================================+==================+ +| Finisar | SFP+ SR bailed, 10g single rate | FTLX8571D3BCL | ++---------------+---------------------------------------+------------------+ +| Avago | SFP+ SR bailed, 10g single rate | AFBR-700SDZ | ++---------------+---------------------------------------+------------------+ +| Finisar | SFP+ LR bailed, 10g single rate | FTLX1471D3BCL | ++---------------+---------------------------------------+------------------+ + +82598-based adapters support all passive direct attach cables that comply with +SFF-8431 v4.1 and SFF-8472 v10.4 specifications. Active direct attach cables +are not supported. + +Third party optic modules and cables referred to above are listed only for the +purpose of highlighting third party specifications and potential +compatibility, and are not recommendations or endorsements or sponsorship of +any third party's product by Intel. Intel is not endorsing or promoting +products made by any third party and the third party reference is provided +only to share information regarding certain optic modules and cables with the +above specifications. There may be other manufacturers or suppliers, producing +or supplying optic modules and cables with similar or matching descriptions. +Customers must use their own discretion and diligence to purchase optic +modules and cables from any third party of their choice. Customers are solely +responsible for assessing the suitability of the product and/or devices and +for the selection of the vendor for purchasing any product. THE OPTIC MODULES +AND CABLES REFERRED TO ABOVE ARE NOT WARRANTED OR SUPPORTED BY INTEL. INTEL +ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED +WARRANTY, RELATING TO SALE AND/OR USE OF SUCH THIRD PARTY PRODUCTS OR +SELECTION OF VENDOR BY CUSTOMERS. + +Command Line Parameters +======================= -SR Modules -Intel DUAL RATE 1G/10G SFP+ SR (bailed) FTLX8571D3BCV-IT -Intel DUAL RATE 1G/10G SFP+ SR (bailed) AFBR-703SDDZ-IN1 -Intel DUAL RATE 1G/10G SFP+ SR (bailed) AFBR-703SDZ-IN2 -LR Modules -Intel DUAL RATE 1G/10G SFP+ LR (bailed) FTLX1471D3BCV-IT -Intel DUAL RATE 1G/10G SFP+ LR (bailed) AFCT-701SDDZ-IN1 -Intel DUAL RATE 1G/10G SFP+ LR (bailed) AFCT-701SDZ-IN2 +max_vfs +------- +:Valid Range: 1-63 -The following is a list of 3rd party SFP+ modules and direct attach cables that -have received some testing. Not all modules are applicable to all devices. +This parameter adds support for SR-IOV. It causes the driver to spawn up to +max_vfs worth of virtual functions. +If the value is greater than 0 it will also force the VMDq parameter to be 1 or +more. -Supplier Type Part Numbers +NOTE: This parameter is only used on kernel 3.7.x and below. On kernel 3.8.x +and above, use sysfs to enable VFs. Also, for Red Hat distributions, this +parameter is only used on version 6.6 and older. For version 6.7 and newer, use +sysfs. For example:: -Finisar SFP+ SR bailed, 10g single rate FTLX8571D3BCL -Avago SFP+ SR bailed, 10g single rate AFBR-700SDZ -Finisar SFP+ LR bailed, 10g single rate FTLX1471D3BCL + #echo $num_vf_enabled > /sys/class/net/$dev/device/sriov_numvfs // enable VFs + #echo 0 > /sys/class/net/$dev/device/sriov_numvfs //disable VFs -Finisar DUAL RATE 1G/10G SFP+ SR (No Bail) FTLX8571D3QCV-IT -Avago DUAL RATE 1G/10G SFP+ SR (No Bail) AFBR-703SDZ-IN1 -Finisar DUAL RATE 1G/10G SFP+ LR (No Bail) FTLX1471D3QCV-IT -Avago DUAL RATE 1G/10G SFP+ LR (No Bail) AFCT-701SDZ-IN1 -Finistar 1000BASE-T SFP FCLF8522P2BTL -Avago 1000BASE-T SFP ABCU-5710RZ +The parameters for the driver are referenced by position. Thus, if you have a +dual port adapter, or more than one adapter in your system, and want N virtual +functions per port, you must specify a number for each port with each parameter +separated by a comma. For example:: -82599-based adapters support all passive and active limiting direct attach -cables that comply with SFF-8431 v4.1 and SFF-8472 v10.4 specifications. + modprobe ixgbe max_vfs=4 -Laser turns off for SFP+ when device is down -------------------------------------------- -"ip link set down" turns off the laser for 82599-based SFP+ fiber adapters. -"ip link set up" turns on the laser. +This will spawn 4 VFs on the first port. +:: -82598-BASED ADAPTERS + modprobe ixgbe max_vfs=2,4 -NOTES for 82598-Based Adapters: -- Intel(R) Network Adapters that support removable optical modules only support - their original module type (i.e., the Intel(R) 10 Gigabit SR Dual Port - Express Module only supports SR optical modules). If you plug in a different - type of module, the driver will not load. -- Hot Swapping/hot plugging optical modules is not supported. -- Only single speed, 10 gigabit modules are supported. -- LAN on Motherboard (LOMs) may support DA, SR, or LR modules. Other module - types are not supported. Please see your system documentation for details. +This will spawn 2 VFs on the first port and 4 VFs on the second port. + +NOTE: Caution must be used in loading the driver with these parameters. +Depending on your system configuration, number of slots, etc., it is impossible +to predict in all cases where the positions would be on the command line. + +NOTE: Neither the device nor the driver control how VFs are mapped into config +space. Bus layout will vary by operating system. On operating systems that +support it, you can check sysfs to find the mapping. + +NOTE: When either SR-IOV mode or VMDq mode is enabled, hardware VLAN filtering +and VLAN tag stripping/insertion will remain enabled. Please remove the old +VLAN filter before the new VLAN filter is added. For example, + +:: + + ip link set eth0 vf 0 vlan 100 // set VLAN 100 for VF 0 + ip link set eth0 vf 0 vlan 0 // Delete VLAN 100 + ip link set eth0 vf 0 vlan 200 // set a new VLAN 200 for VF 0 -The following is a list of 3rd party SFP+ modules and direct attach cables that -have received some testing. Not all modules are applicable to all devices. +With kernel 3.6, the driver supports the simultaneous usage of max_vfs and DCB +features, subject to the constraints described below. Prior to kernel 3.6, the +driver did not support the simultaneous operation of max_vfs greater than 0 and +the DCB features (multiple traffic classes utilizing Priority Flow Control and +Extended Transmission Selection). -Supplier Type Part Numbers +When DCB is enabled, network traffic is transmitted and received through +multiple traffic classes (packet buffers in the NIC). The traffic is associated +with a specific class based on priority, which has a value of 0 through 7 used +in the VLAN tag. When SR-IOV is not enabled, each traffic class is associated +with a set of receive/transmit descriptor queue pairs. The number of queue +pairs for a given traffic class depends on the hardware configuration. When +SR-IOV is enabled, the descriptor queue pairs are grouped into pools. The +Physical Function (PF) and each Virtual Function (VF) is allocated a pool of +receive/transmit descriptor queue pairs. When multiple traffic classes are +configured (for example, DCB is enabled), each pool contains a queue pair from +each traffic class. When a single traffic class is configured in the hardware, +the pools contain multiple queue pairs from the single traffic class. -Finisar SFP+ SR bailed, 10g single rate FTLX8571D3BCL -Avago SFP+ SR bailed, 10g single rate AFBR-700SDZ -Finisar SFP+ LR bailed, 10g single rate FTLX1471D3BCL +The number of VFs that can be allocated depends on the number of traffic +classes that can be enabled. The configurable number of traffic classes for +each enabled VF is as follows: +0 - 15 VFs = Up to 8 traffic classes, depending on device support +16 - 31 VFs = Up to 4 traffic classes +32 - 63 VFs = 1 traffic class -82598-based adapters support all passive direct attach cables that comply -with SFF-8431 v4.1 and SFF-8472 v10.4 specifications. Active direct attach -cables are not supported. +When VFs are configured, the PF is allocated one pool as well. The PF supports +the DCB features with the constraint that each traffic class will only use a +single queue pair. When zero VFs are configured, the PF can support multiple +queue pairs per traffic class. +allow_unsupported_sfp +--------------------- +:Valid Range: 0,1 +:Default Value: 0 (disabled) + +This parameter allows unsupported and untested SFP+ modules on 82599-based +adapters, as long as the type of module is known to the driver. + +debug +----- +:Valid Range: 0-16 (0=none,...,16=all) +:Default Value: 0 + +This parameter adjusts the level of debug messages displayed in the system +logs. + + +Additional Features and Configurations +====================================== Flow Control ------------ Ethernet Flow Control (IEEE 802.3x) can be configured with ethtool to enable -receiving and transmitting pause frames for ixgbe. When TX is enabled, PAUSE -frames are generated when the receive packet buffer crosses a predefined -threshold. When rx is enabled, the transmit unit will halt for the time delay -specified when a PAUSE frame is received. +receiving and transmitting pause frames for ixgbe. When transmit is enabled, +pause frames are generated when the receive packet buffer crosses a predefined +threshold. When receive is enabled, the transmit unit will halt for the time +delay specified when a pause frame is received. + +NOTE: You must have a flow control capable link partner. + +Flow Control is enabled by default. + +Use ethtool to change the flow control settings. To enable or disable Rx or +Tx Flow Control:: + + ethtool -A eth? rx tx + +Note: This command only enables or disables Flow Control if auto-negotiation is +disabled. If auto-negotiation is enabled, this command changes the parameters +used for auto-negotiation with the link partner. + +To enable or disable auto-negotiation:: -Flow Control is enabled by default. If you want to disable a flow control -capable link partner, use ethtool: + ethtool -s eth? autoneg - ethtool -A eth? autoneg off RX off TX off +Note: Flow Control auto-negotiation is part of link auto-negotiation. Depending +on your device, you may not be able to change the auto-negotiation setting. -NOTE: For 82598 backplane cards entering 1 gig mode, flow control default -behavior is changed to off. Flow control in 1 gig mode on these devices can -lead to Tx hangs. +NOTE: For 82598 backplane cards entering 1 gigabit mode, flow control default +behavior is changed to off. Flow control in 1 gigabit mode on these devices can +lead to transmit hangs. Intel(R) Ethernet Flow Director ------------------------------- -Supports advanced filters that direct receive packets by their flows to -different queues. Enables tight control on routing a flow in the platform. -Matches flows and CPU cores for flow affinity. Supports multiple parameters -for flexible flow classification and load balancing. +The Intel Ethernet Flow Director performs the following tasks: -Flow director is enabled only if the kernel is multiple TX queue capable. +- Directs receive packets according to their flows to different queues. +- Enables tight control on routing a flow in the platform. +- Matches flows and CPU cores for flow affinity. +- Supports multiple parameters for flexible flow classification and load + balancing (in SFP mode only). -An included script (set_irq_affinity.sh) automates setting the IRQ to CPU -affinity. +NOTE: Intel Ethernet Flow Director masking works in the opposite manner from +subnet masking. In the following command:: -You can verify that the driver is using Flow Director by looking at the counter -in ethtool: fdir_miss and fdir_match. + #ethtool -N eth11 flow-type ip4 src-ip 172.4.1.2 m 255.0.0.0 dst-ip \ + 172.21.1.1 m 255.128.0.0 action 31 -Other ethtool Commands: -To enable Flow Director - ethtool -K ethX ntuple on -To add a filter - Use -U switch. e.g., ethtool -U ethX flow-type tcp4 src-ip 10.0.128.23 - action 1 -To see the list of filters currently present: - ethtool -u ethX +The src-ip value that is written to the filter will be 0.4.1.2, not 172.0.0.0 +as might be expected. Similarly, the dst-ip value written to the filter will be +0.21.1.1, not 172.0.0.0. -Perfect Filter: Perfect filter is an interface to load the filter table that -funnels all flow into queue_0 unless an alternative queue is specified using -"action". In that case, any flow that matches the filter criteria will be -directed to the appropriate queue. +To enable or disable the Intel Ethernet Flow Director:: -If the queue is defined as -1, filter will drop matching packets. + # ethtool -K ethX ntuple -To account for filter matches and misses, there are two stats in ethtool: -fdir_match and fdir_miss. In addition, rx_queue_N_packets shows the number of -packets processed by the Nth queue. +When disabling ntuple filters, all the user programmed filters are flushed from +the driver cache and hardware. All needed filters must be re-added when ntuple +is re-enabled. -NOTE: Receive Packet Steering (RPS) and Receive Flow Steering (RFS) are not -compatible with Flow Director. IF Flow Director is enabled, these will be -disabled. +To add a filter that directs packet to queue 2, use -U or -N switch:: -The following three parameters impact Flow Director. + # ethtool -N ethX flow-type tcp4 src-ip 192.168.10.1 dst-ip \ + 192.168.10.2 src-port 2000 dst-port 2001 action 2 [loc 1] -FdirMode --------- -Valid Range: 0-2 (0=off, 1=ATR, 2=Perfect filter mode) -Default Value: 1 +To see the list of filters currently present:: - Flow Director filtering modes. + # ethtool <-u|-n> ethX -FdirPballoc ------------ -Valid Range: 0-2 (0=64k, 1=128k, 2=256k) -Default Value: 0 +Sideband Perfect Filters +------------------------ +Sideband Perfect Filters are used to direct traffic that matches specified +characteristics. They are enabled through ethtool's ntuple interface. To add a +new filter use the following command:: - Flow Director allocated packet buffer size. + ethtool -U flow-type src-ip dst-ip src-port \ + dst-port action -AtrSampleRate --------------- -Valid Range: 1-100 -Default Value: 20 +Where: + - the ethernet device to program + - can be ip4, tcp4, udp4, or sctp4 + - the IP address to match on + - the port number to match on + - the queue to direct traffic towards (-1 discards the matched traffic) - Software ATR Tx packet sample rate. For example, when set to 20, every 20th - packet, looks to see if the packet will create a new flow. +Use the following command to delete a filter:: -Node ----- -Valid Range: 0-n -Default Value: 1 (off) + ethtool -U delete - 0 - n: where n is the number of NUMA nodes (i.e. 0 - 3) currently online in - your system - 1: turns this option off +Where is the filter id displayed when printing all the active filters, and +may also have been specified using "loc " when adding the filter. - The Node parameter will allow you to pick which NUMA node you want to have - the adapter allocate memory on. +The following example matches TCP traffic sent from 192.168.0.1, port 5300, +directed to 192.168.0.5, port 80, and sends it to queue 7:: -max_vfs -------- -Valid Range: 1-63 -Default Value: 0 + ethtool -U enp130s0 flow-type tcp4 src-ip 192.168.0.1 dst-ip 192.168.0.5 \ + src-port 5300 dst-port 80 action 7 + +For each flow-type, the programmed filters must all have the same matching +input set. For example, issuing the following two commands is acceptable:: + + ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7 + ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.5 src-port 55 action 10 - If the value is greater than 0 it will also force the VMDq parameter to be 1 - or more. +Issuing the next two commands, however, is not acceptable, since the first +specifies src-ip and the second specifies dst-ip:: - This parameter adds support for SR-IOV. It causes the driver to spawn up to - max_vfs worth of virtual function. + ethtool -U enp130s0 flow-type ip4 src-ip 192.168.0.1 src-port 5300 action 7 + ethtool -U enp130s0 flow-type ip4 dst-ip 192.168.0.5 src-port 55 action 10 +The second command will fail with an error. You may program multiple filters +with the same fields, using different values, but, on one device, you may not +program two TCP4 filters with different matching fields. -Additional Configurations -========================= +Matching on a sub-portion of a field is not supported by the ixgbe driver, thus +partial mask fields are not supported. - Jumbo Frames - ------------ - The driver supports Jumbo Frames for all adapters. Jumbo Frames support is - enabled by changing the MTU to a value larger than the default of 1500. - The maximum value for the MTU is 16110. Use the ip command to - increase the MTU size. For example: +To create filters that direct traffic to a specific Virtual Function, use the +"user-def" parameter. Specify the user-def as a 64 bit value, where the lower 32 +bits represents the queue number, while the next 8 bits represent which VF. +Note that 0 is the PF, so the VF identifier is offset by 1. For example:: - ip link set dev ethx mtu 9000 + ... user-def 0x800000002 ... - The maximum MTU setting for Jumbo Frames is 9710. This value coincides - with the maximum Jumbo Frames size of 9728. +specifies to direct traffic to Virtual Function 7 (8 minus 1) into queue 2 of +that VF. - Generic Receive Offload, aka GRO - -------------------------------- - The driver supports the in-kernel software implementation of GRO. GRO has - shown that by coalescing Rx traffic into larger chunks of data, CPU - utilization can be significantly reduced when under large Rx load. GRO is an - evolution of the previously-used LRO interface. GRO is able to coalesce - other protocols besides TCP. It's also safe to use with configurations that - are problematic for LRO, namely bridging and iSCSI. +Note that these filters will not break internal routing rules, and will not +route traffic that otherwise would not have been sent to the specified Virtual +Function. - Data Center Bridging, aka DCB - ----------------------------- - DCB is a configuration Quality of Service implementation in hardware. - It uses the VLAN priority tag (802.1p) to filter traffic. That means - that there are 8 different priorities that traffic can be filtered into. - It also enables priority flow control which can limit or eliminate the - number of dropped packets during network stress. Bandwidth can be - allocated to each of these priorities, which is enforced at the hardware - level. +Jumbo Frames +------------ +Jumbo Frames support is enabled by changing the Maximum Transmission Unit (MTU) +to a value larger than the default value of 1500. - To enable DCB support in ixgbe, you must enable the DCB netlink layer to - allow the userspace tools (see below) to communicate with the driver. - This can be found in the kernel configuration here: +Use the ifconfig command to increase the MTU size. For example, enter the +following where is the interface number:: - -> Networking support - -> Networking options - -> Data Center Bridging support + ifconfig eth mtu 9000 up - Once this is selected, DCB support must be selected for ixgbe. This can - be found here: +Alternatively, you can use the ip command as follows:: - -> Device Drivers - -> Network device support (NETDEVICES [=y]) - -> Ethernet (10000 Mbit) (NETDEV_10000 [=y]) - -> Intel(R) 10GbE PCI Express adapters support - -> Data Center Bridging (DCB) Support + ip link set mtu 9000 dev eth + ip link set up dev eth - After these options are selected, you must rebuild your kernel and your - modules. +This setting is not saved across reboots. The setting change can be made +permanent by adding 'MTU=9000' to the file:: - In order to use DCB, userspace tools must be downloaded and installed. - The dcbd tools can be found at: + /etc/sysconfig/network-scripts/ifcfg-eth // for RHEL + /etc/sysconfig/network/ // for SLES - http://e1000.sf.net +NOTE: The maximum MTU setting for Jumbo Frames is 9710. This value coincides +with the maximum Jumbo Frames size of 9728 bytes. - Ethtool - ------- - The driver utilizes the ethtool interface for driver configuration and - diagnostics, as well as displaying statistical information. The latest - ethtool version is required for this functionality. +NOTE: This driver will attempt to use multiple page sized buffers to receive +each jumbo packet. This should help to avoid buffer starvation issues when +allocating receive packets. - The latest release of ethtool can be found from - https://www.kernel.org/pub/software/network/ethtool/ +NOTE: For 82599-based network connections, if you are enabling jumbo frames in +a virtual function (VF), jumbo frames must first be enabled in the physical +function (PF). The VF MTU setting cannot be larger than the PF MTU. - FCoE - ---- - This release of the ixgbe driver contains new code to enable users to use - Fiber Channel over Ethernet (FCoE) and Data Center Bridging (DCB) - functionality that is supported by the 82598-based hardware. This code has - no default effect on the regular driver operation, and configuring DCB and - FCoE is outside the scope of this driver README. Refer to - http://www.open-fcoe.org/ for FCoE project information and contact - e1000-eedc@lists.sourceforge.net for DCB information. +Generic Receive Offload, aka GRO +-------------------------------- +The driver supports the in-kernel software implementation of GRO. GRO has +shown that by coalescing Rx traffic into larger chunks of data, CPU +utilization can be significantly reduced when under large Rx load. GRO is an +evolution of the previously-used LRO interface. GRO is able to coalesce +other protocols besides TCP. It's also safe to use with configurations that +are problematic for LRO, namely bridging and iSCSI. - MAC and VLAN anti-spoofing feature - ---------------------------------- - When a malicious driver attempts to send a spoofed packet, it is dropped by - the hardware and not transmitted. An interrupt is sent to the PF driver - notifying it of the spoof attempt. +Data Center Bridging (DCB) +-------------------------- +NOTE: +The kernel assumes that TC0 is available, and will disable Priority Flow +Control (PFC) on the device if TC0 is not available. To fix this, ensure TC0 is +enabled when setting up DCB on your switch. - When a spoofed packet is detected the PF driver will send the following - message to the system log (displayed by the "dmesg" command): +DCB is a configuration Quality of Service implementation in hardware. It uses +the VLAN priority tag (802.1p) to filter traffic. That means that there are 8 +different priorities that traffic can be filtered into. It also enables +priority flow control (802.1Qbb) which can limit or eliminate the number of +dropped packets during network stress. Bandwidth can be allocated to each of +these priorities, which is enforced at the hardware level (802.1Qaz). - Spoof event(s) detected on VF (n) +Adapter firmware implements LLDP and DCBX protocol agents as per 802.1AB and +802.1Qaz respectively. The firmware based DCBX agent runs in willing mode only +and can accept settings from a DCBX capable peer. Software configuration of +DCBX parameters via dcbtool/lldptool are not supported. - Where n=the VF that attempted to do the spoofing. +The ixgbe driver implements the DCB netlink interface layer to allow user-space +to communicate with the driver and query DCB configuration for the port. +ethtool +------- +The driver utilizes the ethtool interface for driver configuration and +diagnostics, as well as displaying statistical information. The latest ethtool +version is required for this functionality. Download it at: +https://www.kernel.org/pub/software/network/ethtool/ -Performance Tuning -================== +FCoE +---- +The ixgbe driver supports Fiber Channel over Ethernet (FCoE) and Data Center +Bridging (DCB). This code has no default effect on the regular driver +operation. Configuring DCB and FCoE is outside the scope of this README. Refer +to http://www.open-fcoe.org/ for FCoE project information and contact +ixgbe-eedc@lists.sourceforge.net for DCB information. -An excellent article on performance tuning can be found at: +MAC and VLAN anti-spoofing feature +---------------------------------- +When a malicious driver attempts to send a spoofed packet, it is dropped by the +hardware and not transmitted. -http://www.redhat.com/promo/summit/2008/downloads/pdf/Thursday/Mark_Wagner.pdf +An interrupt is sent to the PF driver notifying it of the spoof attempt. When a +spoofed packet is detected, the PF driver will send the following message to +the system log (displayed by the "dmesg" command):: + ixgbe ethX: ixgbe_spoof_check: n spoofed packets detected -Known Issues -============ +where "x" is the PF interface number; and "n" is number of spoofed packets. +NOTE: This feature can be disabled for a specific Virtual Function (VF):: - Enabling SR-IOV in a 32-bit or 64-bit Microsoft* Windows* Server 2008/R2 - Guest OS using Intel (R) 82576-based GbE or Intel (R) 82599-based 10GbE - controller under KVM - ------------------------------------------------------------------------ - KVM Hypervisor/VMM supports direct assignment of a PCIe device to a VM. This - includes traditional PCIe devices, as well as SR-IOV-capable devices using - Intel 82576-based and 82599-based controllers. + ip link set vf spoofchk {off|on} - While direct assignment of a PCIe device or an SR-IOV Virtual Function (VF) - to a Linux-based VM running 2.6.32 or later kernel works fine, there is a - known issue with Microsoft Windows Server 2008 VM that results in a "yellow - bang" error. This problem is within the KVM VMM itself, not the Intel driver, - or the SR-IOV logic of the VMM, but rather that KVM emulates an older CPU - model for the guests, and this older CPU model does not support MSI-X - interrupts, which is a requirement for Intel SR-IOV. - If you wish to use the Intel 82576 or 82599-based controllers in SR-IOV mode - with KVM and a Microsoft Windows Server 2008 guest try the following - workaround. The workaround is to tell KVM to emulate a different model of CPU - when using qemu to create the KVM guest: +Known Issues/Troubleshooting +============================ - "-cpu qemu64,model=13" +Enabling SR-IOV in a 64-bit Microsoft* Windows Server* 2012/R2 guest OS +----------------------------------------------------------------------- +Linux KVM Hypervisor/VMM supports direct assignment of a PCIe device to a VM. +This includes traditional PCIe devices, as well as SR-IOV-capable devices based +on the Intel Ethernet Controller XL710. Support ======= - For general information, go to the Intel support website at: - http://support.intel.com +https://www.intel.com/support/ or the Intel Wired Networking project hosted by Sourceforge at: - http://e1000.sourceforge.net +https://sourceforge.net/projects/e1000 -If an issue is identified with the released source code on the supported -kernel with a supported adapter, email the specific information related -to the issue to e1000-devel@lists.sf.net +If an issue is identified with the released source code on a supported kernel +with a supported adapter, email the specific information related to the issue +to e1000-devel@lists.sf.net. -- 2.20.1