From 109d59b900e78834c66657dd4748fcedb9a1fe8d Mon Sep 17 00:00:00 2001 From: Thomas Richter Date: Mon, 26 Mar 2018 10:25:38 +0200 Subject: [PATCH] perf vendor events s390: Add JSON files for IBM z14 Add CPU measurement counter facility event description files (json files) for IBM z14. Signed-off-by: Thomas Richter Reviewed-by: Hendrik Brueckner Cc: Heiko Carstens Cc: Martin Schwidefsky Link: http://lkml.kernel.org/r/20180326082538.2258-5-tmricht@linux.vnet.ibm.com Signed-off-by: Arnaldo Carvalho de Melo --- .../pmu-events/arch/s390/cf_z14/basic.json | 50 +++ .../pmu-events/arch/s390/cf_z14/crypto.json | 98 ++++++ .../pmu-events/arch/s390/cf_z14/extended.json | 320 ++++++++++++++++++ tools/perf/pmu-events/arch/s390/mapfile.csv | 1 + 4 files changed, 469 insertions(+) create mode 100644 tools/perf/pmu-events/arch/s390/cf_z14/basic.json create mode 100644 tools/perf/pmu-events/arch/s390/cf_z14/crypto.json create mode 100644 tools/perf/pmu-events/arch/s390/cf_z14/extended.json diff --git a/tools/perf/pmu-events/arch/s390/cf_z14/basic.json b/tools/perf/pmu-events/arch/s390/cf_z14/basic.json new file mode 100644 index 000000000000..8f653c9d899d --- /dev/null +++ b/tools/perf/pmu-events/arch/s390/cf_z14/basic.json @@ -0,0 +1,50 @@ +[ + { + "EventCode": "0", + "EventName": "CPU_CYCLES", + "BriefDescription": "CPU Cycles", + "PublicDescription": "Cycle Count" + }, + { + "EventCode": "1", + "EventName": "INSTRUCTIONS", + "BriefDescription": "Instructions", + "PublicDescription": "Instruction Count" + }, + { + "EventCode": "2", + "EventName": "L1I_DIR_WRITES", + "BriefDescription": "L1I Directory Writes", + "PublicDescription": "Level-1 I-Cache Directory Write Count" + }, + { + "EventCode": "3", + "EventName": "L1I_PENALTY_CYCLES", + "BriefDescription": "L1I Penalty Cycles", + "PublicDescription": "Level-1 I-Cache Penalty Cycle Count" + }, + { + "EventCode": "4", + "EventName": "L1D_DIR_WRITES", + "BriefDescription": "L1D Directory Writes", + "PublicDescription": "Level-1 D-Cache Directory Write Count" + }, + { + "EventCode": "5", + "EventName": "L1D_PENALTY_CYCLES", + "BriefDescription": "L1D Penalty Cycles", + "PublicDescription": "Level-1 D-Cache Penalty Cycle Count" + }, + { + "EventCode": "32", + "EventName": "PROBLEM_STATE_CPU_CYCLES", + "BriefDescription": "Problem-State CPU Cycles", + "PublicDescription": "Problem-State Cycle Count" + }, + { + "EventCode": "33", + "EventName": "PROBLEM_STATE_INSTRUCTIONS", + "BriefDescription": "Problem-State Instructions", + "PublicDescription": "Problem-State Instruction Count" + }, +] diff --git a/tools/perf/pmu-events/arch/s390/cf_z14/crypto.json b/tools/perf/pmu-events/arch/s390/cf_z14/crypto.json new file mode 100644 index 000000000000..7e5b72492141 --- /dev/null +++ b/tools/perf/pmu-events/arch/s390/cf_z14/crypto.json @@ -0,0 +1,98 @@ +[ + { + "EventCode": "64", + "EventName": "PRNG_FUNCTIONS", + "BriefDescription": "PRNG Functions", + "PublicDescription": "Total number of the PRNG functions issued by the CPU" + }, + { + "EventCode": "65", + "EventName": "PRNG_CYCLES", + "BriefDescription": "PRNG Cycles", + "PublicDescription": "Total number of CPU cycles when the DEA/AES coprocessor is busy performing PRNG functions issued by the CPU" + }, + { + "EventCode": "66", + "EventName": "PRNG_BLOCKED_FUNCTIONS", + "BriefDescription": "PRNG Blocked Functions", + "PublicDescription": "Total number of the PRNG functions that are issued by the CPU and are blocked because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "67", + "EventName": "PRNG_BLOCKED_CYCLES", + "BriefDescription": "PRNG Blocked Cycles", + "PublicDescription": "Total number of CPU cycles blocked for the PRNG functions issued by the CPU because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "68", + "EventName": "SHA_FUNCTIONS", + "BriefDescription": "SHA Functions", + "PublicDescription": "Total number of SHA functions issued by the CPU" + }, + { + "EventCode": "69", + "EventName": "SHA_CYCLES", + "BriefDescription": "SHA Cycles", + "PublicDescription": "Total number of CPU cycles when the SHA coprocessor is busy performing the SHA functions issued by the CPU" + }, + { + "EventCode": "70", + "EventName": "SHA_BLOCKED_FUNCTIONS", + "BriefDescription": "SHA Blocked Functions", + "PublicDescription": "Total number of the SHA functions that are issued by the CPU and are blocked because the SHA coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "71", + "EventName": "SHA_BLOCKED_CYCLES", + "BriefDescription": "SHA Bloced Cycles", + "PublicDescription": "Total number of CPU cycles blocked for the SHA functions issued by the CPU because the SHA coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "72", + "EventName": "DEA_FUNCTIONS", + "BriefDescription": "DEA Functions", + "PublicDescription": "Total number of the DEA functions issued by the CPU" + }, + { + "EventCode": "73", + "EventName": "DEA_CYCLES", + "BriefDescription": "DEA Cycles", + "PublicDescription": "Total number of CPU cycles when the DEA/AES coprocessor is busy performing the DEA functions issued by the CPU" + }, + { + "EventCode": "74", + "EventName": "DEA_BLOCKED_FUNCTIONS", + "BriefDescription": "DEA Blocked Functions", + "PublicDescription": "Total number of the DEA functions that are issued by the CPU and are blocked because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "75", + "EventName": "DEA_BLOCKED_CYCLES", + "BriefDescription": "DEA Blocked Cycles", + "PublicDescription": "Total number of CPU cycles blocked for the DEA functions issued by the CPU because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "76", + "EventName": "AES_FUNCTIONS", + "BriefDescription": "AES Functions", + "PublicDescription": "Total number of AES functions issued by the CPU" + }, + { + "EventCode": "77", + "EventName": "AES_CYCLES", + "BriefDescription": "AES Cycles", + "PublicDescription": "Total number of CPU cycles when the DEA/AES coprocessor is busy performing the AES functions issued by the CPU" + }, + { + "EventCode": "78", + "EventName": "AES_BLOCKED_FUNCTIONS", + "BriefDescription": "AES Blocked Functions", + "PublicDescription": "Total number of AES functions that are issued by the CPU and are blocked because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "79", + "EventName": "AES_BLOCKED_CYCLES", + "BriefDescription": "AES Blocked Cycles", + "PublicDescription": "Total number of CPU cycles blocked for the AES functions issued by the CPU because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, +] diff --git a/tools/perf/pmu-events/arch/s390/cf_z14/extended.json b/tools/perf/pmu-events/arch/s390/cf_z14/extended.json new file mode 100644 index 000000000000..aa4dfb46b65b --- /dev/null +++ b/tools/perf/pmu-events/arch/s390/cf_z14/extended.json @@ -0,0 +1,320 @@ +[ + { + "EventCode": "128", + "EventName": "L1D_RO_EXCL_WRITES", + "BriefDescription": "L1D Read-only Exclusive Writes", + "PublicDescription": "Counter:128 Name:L1D_RO_EXCL_WRITES A directory write to the Level-1 Data cache where the line was originally in a Read-Only state in the cache but has been updated to be in the Exclusive state that allows stores to the cache line" + }, + { + "EventCode": "129", + "EventName": "DTLB2_WRITES", + "BriefDescription": "DTLB2 Writes", + "PublicDescription": "A translation has been written into The Translation Lookaside Buffer 2 (TLB2) and the request was made by the data cache" + }, + { + "EventCode": "130", + "EventName": "DTLB2_MISSES", + "BriefDescription": "DTLB2 Misses", + "PublicDescription": "A TLB2 miss is in progress for a request made by the data cache. Incremented by one for every TLB2 miss in progress for the Level-1 Data cache on this cycle" + }, + { + "EventCode": "131", + "EventName": "DTLB2_HPAGE_WRITES", + "BriefDescription": "DTLB2 One-Megabyte Page Writes", + "PublicDescription": "A translation entry was written into the Combined Region and Segment Table Entry array in the Level-2 TLB for a one-megabyte page or a Last Host Translation was done" + }, + { + "EventCode": "132", + "EventName": "DTLB2_GPAGE_WRITES", + "BriefDescription": "DTLB2 Two-Gigabyte Page Writes", + "PublicDescription": "A translation entry for a two-gigabyte page was written into the Level-2 TLB" + }, + { + "EventCode": "133", + "EventName": "L1D_L2D_SOURCED_WRITES", + "BriefDescription": "L1D L2D Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the Level-2 Data cache" + }, + { + "EventCode": "134", + "EventName": "ITLB2_WRITES", + "BriefDescription": "ITLB2 Writes", + "PublicDescription": "A translation entry has been written into the Translation Lookaside Buffer 2 (TLB2) and the request was made by the instruction cache" + }, + { + "EventCode": "135", + "EventName": "ITLB2_MISSES", + "BriefDescription": "ITLB2 Misses", + "PublicDescription": "A TLB2 miss is in progress for a request made by the instruction cache. Incremented by one for every TLB2 miss in progress for the Level-1 Instruction cache in a cycle" + }, + { + "EventCode": "136", + "EventName": "L1I_L2I_SOURCED_WRITES", + "BriefDescription": "L1I L2I Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the Level-2 Instruction cache" + }, + { + "EventCode": "137", + "EventName": "TLB2_PTE_WRITES", + "BriefDescription": "TLB2 PTE Writes", + "PublicDescription": "A translation entry was written into the Page Table Entry array in the Level-2 TLB" + }, + { + "EventCode": "138", + "EventName": "TLB2_CRSTE_WRITES", + "BriefDescription": "TLB2 CRSTE Writes", + "PublicDescription": "Translation entries were written into the Combined Region and Segment Table Entry array and the Page Table Entry array in the Level-2 TLB" + }, + { + "EventCode": "139", + "EventName": "TLB2_ENGINES_BUSY", + "BriefDescription": "TLB2 Engines Busy", + "PublicDescription": "The number of Level-2 TLB translation engines busy in a cycle" + }, + { + "EventCode": "140", + "EventName": "TX_C_TEND", + "BriefDescription": "Completed TEND instructions in constrained TX mode", + "PublicDescription": "A TEND instruction has completed in a constrained transactional-execution mode" + }, + { + "EventCode": "141", + "EventName": "TX_NC_TEND", + "BriefDescription": "Completed TEND instructions in non-constrained TX mode", + "PublicDescription": "A TEND instruction has completed in a non-constrained transactional-execution mode" + }, + { + "EventCode": "143", + "EventName": "L1C_TLB2_MISSES", + "BriefDescription": "L1C TLB2 Misses", + "PublicDescription": "Increments by one for any cycle where a level-1 cache or level-2 TLB miss is in progress" + }, + { + "EventCode": "144", + "EventName": "L1D_ONCHIP_L3_SOURCED_WRITES", + "BriefDescription": "L1D On-Chip L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-3 cache without intervention" + }, + { + "EventCode": "145", + "EventName": "L1D_ONCHIP_MEMORY_SOURCED_WRITES", + "BriefDescription": "L1D On-Chip Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Chip memory" + }, + { + "EventCode": "146", + "EventName": "L1D_ONCHIP_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1D On-Chip L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-3 cache with intervention" + }, + { + "EventCode": "147", + "EventName": "L1D_ONCLUSTER_L3_SOURCED_WRITES", + "BriefDescription": "L1D On-Cluster L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Cluster Level-3 cache withountervention" + }, + { + "EventCode": "148", + "EventName": "L1D_ONCLUSTER_MEMORY_SOURCED_WRITES", + "BriefDescription": "L1D On-Cluster Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Cluster memory" + }, + { + "EventCode": "149", + "EventName": "L1D_ONCLUSTER_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1D On-Cluster L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Cluster Level-3 cache with intervention" + }, + { + "EventCode": "150", + "EventName": "L1D_OFFCLUSTER_L3_SOURCED_WRITES", + "BriefDescription": "L1D Off-Cluster L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Cluster Level-3 cache without intervention" + }, + { + "EventCode": "151", + "EventName": "L1D_OFFCLUSTER_MEMORY_SOURCED_WRITES", + "BriefDescription": "L1D Off-Cluster Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from Off-Cluster memory" + }, + { + "EventCode": "152", + "EventName": "L1D_OFFCLUSTER_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1D Off-Cluster L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Cluster Level-3 cache with intervention" + }, + { + "EventCode": "153", + "EventName": "L1D_OFFDRAWER_L3_SOURCED_WRITES", + "BriefDescription": "L1D Off-Drawer L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Level-3 cache without intervention" + }, + { + "EventCode": "154", + "EventName": "L1D_OFFDRAWER_MEMORY_SOURCED_WRITES", + "BriefDescription": "L1D Off-Drawer Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from Off-Drawer memory" + }, + { + "EventCode": "155", + "EventName": "L1D_OFFDRAWER_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1D Off-Drawer L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Level-3 cache with intervention" + }, + { + "EventCode": "156", + "EventName": "L1D_ONDRAWER_L4_SOURCED_WRITES", + "BriefDescription": "L1D On-Drawer L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Drawer Level-4 cache" + }, + { + "EventCode": "157", + "EventName": "L1D_OFFDRAWER_L4_SOURCED_WRITES", + "BriefDescription": "L1D Off-Drawer L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from Off-Drawer Level-4 cache" + }, + { + "EventCode": "158", + "EventName": "L1D_ONCHIP_L3_SOURCED_WRITES_RO", + "BriefDescription": "L1D On-Chip L3 Sourced Writes read-only", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Chip L3 but a read-only invalidate was done to remove other copies of the cache line" + }, + { + "EventCode": "162", + "EventName": "L1I_ONCHIP_L3_SOURCED_WRITES", + "BriefDescription": "L1I On-Chip L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache ine was sourced from an On-Chip Level-3 cache without intervention" + }, + { + "EventCode": "163", + "EventName": "L1I_ONCHIP_MEMORY_SOURCED_WRITES", + "BriefDescription": "L1I On-Chip Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache ine was sourced from On-Chip memory" + }, + { + "EventCode": "164", + "EventName": "L1I_ONCHIP_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1I On-Chip L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache ine was sourced from an On-Chip Level-3 cache with intervention" + }, + { + "EventCode": "165", + "EventName": "L1I_ONCLUSTER_L3_SOURCED_WRITES", + "BriefDescription": "L1I On-Cluster L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Cluster Level-3 cache without intervention" + }, + { + "EventCode": "166", + "EventName": "L1I_ONCLUSTER_MEMORY_SOURCED_WRITES", + "BriefDescription": "L1I On-Cluster Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Cluster memory" + }, + { + "EventCode": "167", + "EventName": "L1I_ONCLUSTER_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1I On-Cluster L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Cluster Level-3 cache with intervention" + }, + { + "EventCode": "168", + "EventName": "L1I_OFFCLUSTER_L3_SOURCED_WRITES", + "BriefDescription": "L1I Off-Cluster L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Cluster Level-3 cache without intervention" + }, + { + "EventCode": "169", + "EventName": "L1I_OFFCLUSTER_MEMORY_SOURCED_WRITES", + "BriefDescription": "L1I Off-Cluster Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from Off-Cluster memory" + }, + { + "EventCode": "170", + "EventName": "L1I_OFFCLUSTER_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1I Off-Cluster L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Cluster Level-3 cache with intervention" + }, + { + "EventCode": "171", + "EventName": "L1I_OFFDRAWER_L3_SOURCED_WRITES", + "BriefDescription": "L1I Off-Drawer L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-3 cache without intervention" + }, + { + "EventCode": "172", + "EventName": "L1I_OFFDRAWER_MEMORY_SOURCED_WRITES", + "BriefDescription": "L1I Off-Drawer Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from Off-Drawer memory" + }, + { + "EventCode": "173", + "EventName": "L1I_OFFDRAWER_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1I Off-Drawer L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-3 cache with intervention" + }, + { + "EventCode": "174", + "EventName": "L1I_ONDRAWER_L4_SOURCED_WRITES", + "BriefDescription": "L1I On-Drawer L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Drawer Level-4 cache" + }, + { + "EventCode": "175", + "EventName": "L1I_OFFDRAWER_L4_SOURCED_WRITES", + "BriefDescription": "L1I Off-Drawer L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from Off-Drawer Level-4 cache" + }, + { + "EventCode": "224", + "EventName": "BCD_DFP_EXECUTION_SLOTS", + "BriefDescription": "BCD DFP Execution Slots", + "PublicDescription": "Count of floating point execution slots used for finished Binary Coded Decimal to Decimal Floating Point conversions. Instructions: CDZT, CXZT, CZDT, CZXT" + }, + { + "EventCode": "225", + "EventName": "VX_BCD_EXECUTION_SLOTS", + "BriefDescription": "VX BCD Execution Slots", + "PublicDescription": "Count of floating point execution slots used for finished vector arithmetic Binary Coded Decimal instructions. Instructions: VAP, VSP, VMPVMSP, VDP, VSDP, VRP, VLIP, VSRP, VPSOPVCP, VTP, VPKZ, VUPKZ, VCVB, VCVBG, VCVDVCVDG" + }, + { + "EventCode": "226", + "EventName": "DECIMAL_INSTRUCTIONS", + "BriefDescription": "Decimal Instructions", + "PublicDescription": "Decimal instructions dispatched. Instructions: CVB, CVD, AP, CP, DP, ED, EDMK, MP, SRP, SP, ZAP" + }, + { + "EventCode": "232", + "EventName": "LAST_HOST_TRANSLATIONS", + "BriefDescription": "Last host translation done", + "PublicDescription": "Last Host Translation done" + }, + { + "EventCode": "243", + "EventName": "TX_NC_TABORT", + "BriefDescription": "Aborted transactions in non-constrained TX mode", + "PublicDescription": "A transaction abort has occurred in a non-constrained transactional-execution mode" + }, + { + "EventCode": "244", + "EventName": "TX_C_TABORT_NO_SPECIAL", + "BriefDescription": "Aborted transactions in constrained TX mode not using special completion logic", + "PublicDescription": "A transaction abort has occurred in a constrained transactional-execution mode and the CPU is not using any special logic to allow the transaction to complete" + }, + { + "EventCode": "245", + "EventName": "TX_C_TABORT_SPECIAL", + "BriefDescription": "Aborted transactions in constrained TX mode using special completion logic", + "PublicDescription": "A transaction abort has occurred in a constrained transactional-execution mode and the CPU is using special logic to allow the transaction to complete" + }, + { + "EventCode": "448", + "EventName": "MT_DIAG_CYCLES_ONE_THR_ACTIVE", + "BriefDescription": "Cycle count with one thread active", + "PublicDescription": "Cycle count with one thread active" + }, + { + "EventCode": "449", + "EventName": "MT_DIAG_CYCLES_TWO_THR_ACTIVE", + "BriefDescription": "Cycle count with two threads active", + "PublicDescription": "Cycle count with two threads active" + }, +] diff --git a/tools/perf/pmu-events/arch/s390/mapfile.csv b/tools/perf/pmu-events/arch/s390/mapfile.csv index 3cff9c64bb85..ca7682748a4b 100644 --- a/tools/perf/pmu-events/arch/s390/mapfile.csv +++ b/tools/perf/pmu-events/arch/s390/mapfile.csv @@ -3,3 +3,4 @@ Family-model,Version,Filename,EventType 281[78],1,cf_z196,core 282[78],1,cf_zec12,core 296[45],1,cf_z13,core +3906,3,cf_z14,core -- 2.20.1