ptp: ocp: Add signal generators and update sysfs nodes
authorJonathan Lemon <jonathan.lemon@gmail.com>
Thu, 10 Mar 2022 20:19:08 +0000 (12:19 -0800)
committerDavid S. Miller <davem@davemloft.net>
Fri, 11 Mar 2022 11:54:45 +0000 (11:54 +0000)
commitb325af3cfab970efa59b69cbcd9890be54713cef
tree3fb69e6f7e56d362a6c32aeb5e3630708adcb4ee
parentc205d53c4923e4b32b4a2a2773618f08e176a250
ptp: ocp: Add signal generators and update sysfs nodes

Newer firmware provides 4 programmable signal generators, add
support for those here.  The signal generators provide the
ability to set the period, duty cycle, phase offset, and polarity,
with new values defaulting to prior values.

The period and phase offset are specified in nanoseconds.

E.g:    period [duty [phase [polarity]]]

  echo 500000000 > signal # 1/2 second period
  echo 1000000 40 100 > signal # 1ms period, 40% on, offset 100ns
  echo 0 > signal # turn off generator

Signed-off-by: Jonathan Lemon <jonathan.lemon@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/ptp/ptp_ocp.c