octeontx2-pf: Add tc flower hardware offload on ingress traffic
This patch adds support for tc flower hardware offload on ingress
traffic. Since the tc-flower filter rules use the same set of MCAM
rules as the n-tuple filters, the n-tuple filters and tc flower
rules are mutually exclusive. When one of the feature is enabled
using ethtool, the other feature is disabled in the driver. By default
the driver enables n-tuple filters during initialization.
The following flow keys are supported.
-> Ethernet: dst_mac
-> L2 proto: all protocols
-> VLAN (802.1q): vlan_id/vlan_prio
-> IPv4: dst_ip/src_ip/ip_proto{tcp|udp|sctp|icmp}/ip_tos
-> IPv6: ip_proto{icmpv6}
-> L4(tcp/udp/sctp): dst_port/src_port
The following flow actions are supported.
-> drop
-> accept
-> redirect
-> vlan pop
The flow action supports multiple actions when vlan pop is specified
as the first action. The redirect action supports redirecting to the
PF/VF of same PCI device. Redirecting to other PCI NIX devices is not
supported.
Example #1: Add a tc filter rule to drop UDP traffic with dest port 80
# ethtool -K eth0 hw-tc-offload on
# tc qdisc add dev eth0 ingress
# tc filter add dev eth0 protocol ip parent ffff: flower ip_proto \
udp dst_port 80 action drop
Example #2: Add a tc filter rule to redirect ingress traffic on eth0
with vlan id 3 to eth6 (ex: eth0 vf0) after stripping the vlan hdr.
# ethtool -K eth0 hw-tc-offload on
# tc qdisc add dev eth0 ingress
# tc filter add dev eth0 parent ffff: protocol 802.1Q flower \
vlan_id 3 vlan_ethtype ipv4 action vlan pop action mirred \
ingress redirect dev eth6
Example #3: List the ingress filter rules
# tc -s filter show dev eth4 ingress
Example #4: Delete tc flower filter rule with handle 0x1
# tc filter del dev eth0 ingress protocol ip pref 49152 \
handle 1 flower
Signed-off-by: Naveen Mamindlapalli <naveenm@marvell.com>
Signed-off-by: David S. Miller <davem@davemloft.net>