iio: adc: ti-ads1015: add 10% to conversion wait time
authorLadislav Michl <ladis@linux-mips.org>
Fri, 25 Aug 2017 05:39:16 +0000 (07:39 +0200)
committerJonathan Cameron <Jonathan.Cameron@huawei.com>
Sun, 3 Sep 2017 17:10:31 +0000 (18:10 +0100)
As user's guide "ADS1015EVM, ADS1115EVM, ADS1015EVM-PDK, ADS1115EVM-PDK
User Guide (Rev. B)" (http://www.ti.com/lit/ug/sbau157b/sbau157b.pdf)
states at page 16:
"Note that both the ADS1115 and ADS1015 have internal clocks with a ±10%
accuracy. If performing FFT tests, frequencies may appear to be incorrect
as a result of this tolerance range.", add those 10% to converion wait
time.

Cc: Daniel Baluta <daniel.baluta@gmail.com>
Cc: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Ladislav Michl <ladis@linux-mips.org>
Reviewed-by: Akinobu Mita <akinobu.mita@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
drivers/iio/adc/ti-ads1015.c

index 7503ea5..3e9719e 100644 (file)
@@ -368,6 +368,7 @@ int ads1015_get_adc_result(struct ads1015_data *data, int chan, int *val)
                dr_old = (old & ADS1015_CFG_DR_MASK) >> ADS1015_CFG_DR_SHIFT;
                conv_time = DIV_ROUND_UP(USEC_PER_SEC, data->data_rate[dr_old]);
                conv_time += DIV_ROUND_UP(USEC_PER_SEC, data->data_rate[dr]);
+               conv_time += conv_time / 10; /* 10% internal clock inaccuracy */
                usleep_range(conv_time, conv_time + 1);
                data->conv_invalid = false;
        }