net/mlx5: Fix forced completion access non initialized command entry
authorMoshe Shemesh <moshe@mellanox.com>
Sun, 21 Jul 2019 05:40:13 +0000 (08:40 +0300)
committerSaeed Mahameed <saeedm@mellanox.com>
Thu, 30 Apr 2020 16:20:32 +0000 (09:20 -0700)
mlx5_cmd_flush() will trigger forced completions to all valid command
entries. Triggered by an asynch event such as fast teardown it can
happen at any stage of the command, including command initialization.
It will trigger forced completion and that can lead to completion on an
uninitialized command entry.

Setting MLX5_CMD_ENT_STATE_PENDING_COMP only after command entry is
initialized will ensure force completion is treated only if command
entry is initialized.

Fixes: 73dd3a4839c1 ("net/mlx5: Avoid using pending command interface slots")
Signed-off-by: Moshe Shemesh <moshe@mellanox.com>
Signed-off-by: Eran Ben Elisha <eranbe@mellanox.com>
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
drivers/net/ethernet/mellanox/mlx5/core/cmd.c

index 34cba97..d7470f8 100644 (file)
@@ -888,7 +888,6 @@ static void cmd_work_handler(struct work_struct *work)
        }
 
        cmd->ent_arr[ent->idx] = ent;
-       set_bit(MLX5_CMD_ENT_STATE_PENDING_COMP, &ent->state);
        lay = get_inst(cmd, ent->idx);
        ent->lay = lay;
        memset(lay, 0, sizeof(*lay));
@@ -910,6 +909,7 @@ static void cmd_work_handler(struct work_struct *work)
 
        if (ent->callback)
                schedule_delayed_work(&ent->cb_timeout_work, cb_timeout);
+       set_bit(MLX5_CMD_ENT_STATE_PENDING_COMP, &ent->state);
 
        /* Skip sending command to fw if internal error */
        if (pci_channel_offline(dev->pdev) ||