If the station has no HT, we deny the aggregation session
but the error message talks about QoS; change it to say HT
instead.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
if (!sta->sta.deflink.ht_cap.ht_supported &&
sta->sdata->vif.bss_conf.chandef.chan->band != NL80211_BAND_6GHZ) {
ht_dbg(sta->sdata,
- "STA %pM erroneously requests BA session on tid %d w/o QoS\n",
+ "STA %pM erroneously requests BA session on tid %d w/o HT\n",
sta->sta.addr, tid);
/* send a response anyway, it's an error case if we get here */
goto end;