Current logic is performing hard reset and causing the programmed
registers to be wiped out.
as per datasheet: https://www.ti.com/lit/ds/symlink/dp83867cr.pdf
8.6.26 Control Register (CTRL)
do SW_RESTART to perform a reset not including the registers,
If performed when link is already present,
it will drop the link and trigger re-auto negotiation.
Signed-off-by: Praneeth Bajjuri <praneeth@ti.com>
Signed-off-by: Geet Modi <geet.modi@ti.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
{
int err;
- err = phy_write(phydev, DP83867_CTRL, DP83867_SW_RESET);
+ err = phy_write(phydev, DP83867_CTRL, DP83867_SW_RESTART);
if (err < 0)
return err;
usleep_range(10, 20);
- /* After reset FORCE_LINK_GOOD bit is set. Although the
- * default value should be unset. Disable FORCE_LINK_GOOD
- * for the phy to work properly.
- */
return phy_modify(phydev, MII_DP83867_PHYCTRL,
DP83867_PHYCR_FORCE_LINK_GOOD, 0);
}