- clock-names: Must include the following entries:
- mc: the module's clock input
- interrupts: The interrupt outputs from the controller.
+- #reset-cells : Should be 1. This cell represents memory client module ID.
+ The assignments may be found in header file <dt-bindings/memory/tegra30-mc.h>
+ or in the TRM documentation.
Required properties for Tegra30, Tegra114, Tegra124, Tegra132 and Tegra210:
- #iommu-cells: Should be 1. The single cell of the IOMMU specifier defines
interrupts = <GIC_SPI 77 IRQ_TYPE_LEVEL_HIGH>;
#iommu-cells = <1>;
+ #reset-cells = <1>;
};
sdhci@700b0000 {
compatible = "nvidia,tegra124-sdhci";
...
iommus = <&mc TEGRA_SWGROUP_SDMMC1A>;
+ resets = <&mc TEGRA124_MC_RESET_SDMMC1>;
};
};