Extend BAM dt bindings with controlled-remotely property. The
property will be needed to handle cases where we need to skip
register writes to initialise BAM hardware block.
Signed-off-by: Stanimir Varbanov <stanimir.varbanov@linaro.org>
Reviewed-by: Andy Gross <andy.gross@linaro.org>
Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Vinod Koul <vinod.koul@intel.com>
- clock-names: must contain "bam_clk" entry
- qcom,ee : indicates the active Execution Environment identifier (0-7) used in
the secure world.
+- qcom,controlled-remotely : optional, indicates that the bam is controlled by
+ remote proccessor i.e. execution environment.
Example: