scsi: qedi: Fix misleading indentation
authorBart Van Assche <bart.vanassche@wdc.com>
Mon, 25 Jun 2018 15:05:16 +0000 (08:05 -0700)
committerMartin K. Petersen <martin.petersen@oracle.com>
Tue, 26 Jun 2018 16:30:11 +0000 (12:30 -0400)
This patch avoids that smatch reports the following warnings:

drivers/scsi/qedi/qedi_fw_api.c:129: init_sqe() warn: inconsistent indenting
drivers/scsi/qedi/qedi_fw_api.c:137: init_sqe() warn: inconsistent indenting

Signed-off-by: Bart Van Assche <bart.vanassche@wdc.com>
Cc: QLogic-Storage-Upstream@cavium.com
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
drivers/scsi/qedi/qedi_fw_api.c

index a269da1..387dc87 100644 (file)
@@ -126,22 +126,24 @@ static void init_sqe(struct iscsi_task_params *task_params,
                                                     sgl_task_params,
                                                     dif_task_params);
 
-               if (scsi_is_slow_sgl(sgl_task_params->num_sges,
-                                    sgl_task_params->small_mid_sge))
-                       num_sges = ISCSI_WQE_NUM_SGES_SLOWIO;
-               else
-                       num_sges = min(sgl_task_params->num_sges,
-                                      (u16)SCSI_NUM_SGES_SLOW_SGL_THR);
-       }
+                       if (scsi_is_slow_sgl(sgl_task_params->num_sges,
+                                            sgl_task_params->small_mid_sge))
+                               num_sges = ISCSI_WQE_NUM_SGES_SLOWIO;
+                       else
+                               num_sges = min(sgl_task_params->num_sges,
+                                              (u16)SCSI_NUM_SGES_SLOW_SGL_THR);
+               }
 
-       SET_FIELD(task_params->sqe->flags, ISCSI_WQE_NUM_SGES, num_sges);
-       SET_FIELD(task_params->sqe->contlen_cdbsize, ISCSI_WQE_CONT_LEN,
-                 buf_size);
+               SET_FIELD(task_params->sqe->flags, ISCSI_WQE_NUM_SGES,
+                         num_sges);
+               SET_FIELD(task_params->sqe->contlen_cdbsize, ISCSI_WQE_CONT_LEN,
+                         buf_size);
 
-       if (GET_FIELD(pdu_header->hdr_second_dword,
-                     ISCSI_CMD_HDR_TOTAL_AHS_LEN))
-               SET_FIELD(task_params->sqe->contlen_cdbsize, ISCSI_WQE_CDB_SIZE,
-                         cmd_params->extended_cdb_sge.sge_len);
+               if (GET_FIELD(pdu_header->hdr_second_dword,
+                             ISCSI_CMD_HDR_TOTAL_AHS_LEN))
+                       SET_FIELD(task_params->sqe->contlen_cdbsize,
+                                 ISCSI_WQE_CDB_SIZE,
+                                 cmd_params->extended_cdb_sge.sge_len);
        }
                break;
        case ISCSI_TASK_TYPE_INITIATOR_READ: