The example for the TI Palmas ADC is incomplete as the binding is the
full PMIC, not just the sub-functions. It is preferred for MFD examples
to be complete in the top-level MFD device binding rather than piecemeal
in each sub-function binding.
This also fixes an undocumented (by schema) compatible warning for
'"ti,twl6035-pmic", "ti,palmas-pmic"'.
Signed-off-by: Rob Herring <robh@kernel.org>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Link: https://lore.kernel.org/r/20231128214803.3975542-1-robh@kernel.org
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
- compatible
- "#io-channel-cells"
-examples:
- - |
- #include <dt-bindings/clock/mt8183-clk.h>
- pmic {
- compatible = "ti,twl6035-pmic", "ti,palmas-pmic";
- adc {
- compatible = "ti,palmas-gpadc";
- interrupts = <18 0>,
- <16 0>,
- <17 0>;
- #io-channel-cells = <1>;
- ti,channel0-current-microamp = <5>;
- ti,channel3-current-microamp = <10>;
- };
- };
...