VIA VT6306, VIA VT6308, and NEC OrangeLink controllers do not write
packet event codes for received PHY packets (or perhaps write
evt_no_status, hard to tell).  Work around it by overwriting the
packet's ACK by ack_complete, so that upper layers that listen to PHY
packet reception get to see these packets.
(Also tested:  TI TSB82AA2, TI TSB43AB22/A, TI XIO2213A, Agere FW643,
JMicron JMB381 --- these do not exhibit this bug.)
Clemens proposed a quirks flag for that, IOW whitelist known misbehaving
controllers for this workaround.  Though to me it seems harmless enough
to enable for all controllers.
The log_ar_at_event() debug log will continue to show the original
status from the DMA unit.
Reported-by: Clemens Ladisch <clemens@ladisch.de> (VT6308)
Signed-off-by: Stefan Richter <stefanr@s5r6.in-berlin.de>
        log_ar_at_event('R', p.speed, p.header, evt);
 
        /*
-        * The OHCI bus reset handler synthesizes a phy packet with
+        * Several controllers, notably from NEC and VIA, forget to
+        * write ack_complete status at PHY packet reception.
+        */
+       if (evt == OHCI1394_evt_no_status &&
+           (p.header[0] & 0xff) == (OHCI1394_phy_tcode << 4))
+               p.ack = ACK_COMPLETE;
+
+       /*
+        * The OHCI bus reset handler synthesizes a PHY packet with
         * the new generation number when a bus reset happens (see
         * section 8.4.2.3).  This helps us determine when a request
         * was received and make sure we send the response in the same