As per section 35.3.1 Starting Reception for the MIPI CSI-2 Input on the
latest hardware manual (R01UH0914EJ0140 Rev.1.40) it is mentioned that
after DPHY reset, we need to wait for 1 msec or more before start
receiving data from the sensor. So add a delay after pre_streamon().
Signed-off-by: Biju Das <biju.das.jz@bp.renesas.com>
Reviewed-by: Laurent Pinchart <laurent.pinchart+renesas@ideasonboard.com>
Link: https://lore.kernel.org/r/20240213181233.242316-3-biju.das.jz@bp.renesas.com
Signed-off-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
* Copyright (C) 2022 Renesas Electronics Corp.
*/
+#include <linux/delay.h>
#include "rzg2l-cru.h"
struct rzg2l_cru_ip_format {
if (ret)
return ret;
+ fsleep(1000);
+
ret = rzg2l_cru_start_image_processing(cru);
if (ret) {
v4l2_subdev_call(cru->ip.remote, video, post_streamoff);