The check for whether a TX ring slot was available was incorrect,
since a slot which had been loaded with transmit data but the device had
not started transmitting would be treated as available, potentially
causing non-transmitted slots to be overwritten. The control field in
the descriptor should be checked, rather than the status field (which may
only be updated when the device completes the entry).
Fixes:
8a3b7a252dca9 ("drivers/net/ethernet/xilinx: added Xilinx AXI Ethernet driver")
Signed-off-by: Robert Hancock <robert.hancock@calian.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
if (cur_p->skb && (status & XAXIDMA_BD_STS_COMPLETE_MASK))
dev_consume_skb_irq(cur_p->skb);
- cur_p->cntrl = 0;
cur_p->app0 = 0;
cur_p->app1 = 0;
cur_p->app2 = 0;
cur_p->skb = NULL;
/* ensure our transmit path and device don't prematurely see status cleared */
wmb();
+ cur_p->cntrl = 0;
cur_p->status = 0;
if (sizep)
/* Ensure we see all descriptor updates from device or TX IRQ path */
rmb();
cur_p = &lp->tx_bd_v[(lp->tx_bd_tail + num_frag) % lp->tx_bd_num];
- if (cur_p->status & XAXIDMA_BD_STS_ALL_MASK)
+ if (cur_p->cntrl)
return NETDEV_TX_BUSY;
return 0;
}