For IR context, ALSA IEC 61883-1/6 engine uses initial value of data
block counter as UINT_MAX, to detect first isochronous packet in the
middle of packet streaming.
At present, when CIP_NO_HEADER is used (i.e. for ALSA fireface driver),
the initial value is used for tracepoints event. 0x00 should be
for the event when the initial value is UINT_MAX because isochronous
packets with CIP_NO_HEADER option has no field for data block count.
This commit fixes the bug.
Fixes:
76864868dbab ("ALSA: firewire-lib: cache next data_block_counter after probing tracepoints event for IR context")
Signed-off-by: Takashi Sakamoto <o-takashi@sakamocchi.jp>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
err = 0;
*data_blocks = *payload_length / sizeof(__be32) /
s->data_block_quadlets;
- *dbc = s->data_block_counter;
*syt = 0;
+
+ if (s->data_block_counter != UINT_MAX)
+ *dbc = s->data_block_counter;
+ else
+ *dbc = 0;
}
if (err >= 0 && s->flags & CIP_DBC_IS_END_EVENT)