--- /dev/null
+/*
+ * Scsi Host Layer for MPT (Message Passing Technology) based controllers
+ *
+ * Copyright (C) 2012-2014 LSI Corporation
+ * Copyright (C) 2013-2015 Avago Technologies
+ * (mailto: MPT-FusionLinux.pdl@avagotech.com)
+ *
+ * This program is free software; you can redistribute it and/or
+ * modify it under the terms of the GNU General Public License
+ * as published by the Free Software Foundation; either version 2
+ * of the License, or (at your option) any later version.
+ *
+ * This program is distributed in the hope that it will be useful,
+ * but WITHOUT ANY WARRANTY; without even the implied warranty of
+ * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
+ * GNU General Public License for more details.
+ *
+ * NO WARRANTY
+ * THE PROGRAM IS PROVIDED ON AN "AS IS" BASIS, WITHOUT WARRANTIES OR
+ * CONDITIONS OF ANY KIND, EITHER EXPRESS OR IMPLIED INCLUDING, WITHOUT
+ * LIMITATION, ANY WARRANTIES OR CONDITIONS OF TITLE, NON-INFRINGEMENT,
+ * MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Each Recipient is
+ * solely responsible for determining the appropriateness of using and
+ * distributing the Program and assumes all risks associated with its
+ * exercise of rights under this Agreement, including but not limited to
+ * the risks and costs of program errors, damage to or loss of data,
+ * programs or equipment, and unavailability or interruption of operations.
+
+ * DISCLAIMER OF LIABILITY
+ * NEITHER RECIPIENT NOR ANY CONTRIBUTORS SHALL HAVE ANY LIABILITY FOR ANY
+ * DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
+ * DAMAGES (INCLUDING WITHOUT LIMITATION LOST PROFITS), HOWEVER CAUSED AND
+ * ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR
+ * TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE
+ * USE OR DISTRIBUTION OF THE PROGRAM OR THE EXERCISE OF ANY RIGHTS GRANTED
+ * HEREUNDER, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES
+
+ * You should have received a copy of the GNU General Public License
+ * along with this program.
+ */
+
+/**
+ * _scsih_disable_ddio - Disable direct I/O for all the volumes
+ * @ioc: per adapter object
+ */
+static void
+_scsih_disable_ddio(struct MPT3SAS_ADAPTER *ioc)
+{
+ Mpi2RaidVolPage1_t vol_pg1;
+ Mpi2ConfigReply_t mpi_reply;
+ struct _raid_device *raid_device;
+ u16 handle;
+ u16 ioc_status;
+ unsigned long flags;
+
+ handle = 0xFFFF;
+ while (!(mpt3sas_config_get_raid_volume_pg1(ioc, &mpi_reply,
+ &vol_pg1, MPI2_RAID_VOLUME_PGAD_FORM_GET_NEXT_HANDLE, handle))) {
+ ioc_status = le16_to_cpu(mpi_reply.IOCStatus) &
+ MPI2_IOCSTATUS_MASK;
+ if (ioc_status == MPI2_IOCSTATUS_CONFIG_INVALID_PAGE)
+ break;
+ handle = le16_to_cpu(vol_pg1.DevHandle);
+ spin_lock_irqsave(&ioc->raid_device_lock, flags);
+ raid_device = _scsih_raid_device_find_by_handle(ioc, handle);
+ if (raid_device)
+ raid_device->direct_io_enabled = 0;
+ spin_unlock_irqrestore(&ioc->raid_device_lock, flags);
+ }
+ return;
+}
+
+
+/**
+ * _scsih_get_num_volumes - Get number of volumes in the ioc
+ * @ioc: per adapter object
+ */
+static u8
+_scsih_get_num_volumes(struct MPT3SAS_ADAPTER *ioc)
+{
+ Mpi2RaidVolPage1_t vol_pg1;
+ Mpi2ConfigReply_t mpi_reply;
+ u16 handle;
+ u8 vol_cnt = 0;
+ u16 ioc_status;
+
+ handle = 0xFFFF;
+ while (!(mpt3sas_config_get_raid_volume_pg1(ioc, &mpi_reply,
+ &vol_pg1, MPI2_RAID_VOLUME_PGAD_FORM_GET_NEXT_HANDLE, handle))) {
+ ioc_status = le16_to_cpu(mpi_reply.IOCStatus) &
+ MPI2_IOCSTATUS_MASK;
+ if (ioc_status == MPI2_IOCSTATUS_CONFIG_INVALID_PAGE)
+ break;
+ vol_cnt++;
+ handle = le16_to_cpu(vol_pg1.DevHandle);
+ }
+ return vol_cnt;
+}
+
+
+/**
+ * _scsih_init_warpdrive_properties - Set properties for warpdrive direct I/O.
+ * @ioc: per adapter object
+ * @raid_device: the raid_device object
+ */
+static void
+_scsih_init_warpdrive_properties(struct MPT3SAS_ADAPTER *ioc,
+ struct _raid_device *raid_device)
+{
+ Mpi2RaidVolPage0_t *vol_pg0;
+ Mpi2RaidPhysDiskPage0_t pd_pg0;
+ Mpi2ConfigReply_t mpi_reply;
+ u16 sz;
+ u8 num_pds, count;
+ unsigned long stripe_sz, block_sz;
+ u8 stripe_exp, block_exp;
+ u64 dev_max_lba;
+
+ if (!ioc->is_warpdrive)
+ return;
+
+ if (ioc->mfg_pg10_hide_flag == MFG_PAGE10_EXPOSE_ALL_DISKS) {
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is disabled "
+ "globally as drives are exposed\n", ioc->name);
+ return;
+ }
+ if (_scsih_get_num_volumes(ioc) > 1) {
+ _scsih_disable_ddio(ioc);
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is disabled "
+ "globally as number of drives > 1\n", ioc->name);
+ return;
+ }
+ if ((mpt3sas_config_get_number_pds(ioc, raid_device->handle,
+ &num_pds)) || !num_pds) {
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is disabled "
+ "Failure in computing number of drives\n", ioc->name);
+ return;
+ }
+
+ sz = offsetof(Mpi2RaidVolPage0_t, PhysDisk) + (num_pds *
+ sizeof(Mpi2RaidVol0PhysDisk_t));
+ vol_pg0 = kzalloc(sz, GFP_KERNEL);
+ if (!vol_pg0) {
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is disabled "
+ "Memory allocation failure for RVPG0\n", ioc->name);
+ return;
+ }
+
+ if ((mpt3sas_config_get_raid_volume_pg0(ioc, &mpi_reply, vol_pg0,
+ MPI2_RAID_VOLUME_PGAD_FORM_HANDLE, raid_device->handle, sz))) {
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is disabled "
+ "Failure in retrieving RVPG0\n", ioc->name);
+ kfree(vol_pg0);
+ return;
+ }
+
+ /*
+ * WARPDRIVE:If number of physical disks in a volume exceeds the max pds
+ * assumed for WARPDRIVE, disable direct I/O
+ */
+ if (num_pds > MPT_MAX_WARPDRIVE_PDS) {
+ pr_warn(MPT3SAS_FMT "WarpDrive : Direct IO is disabled "
+ "for the drive with handle(0x%04x): num_mem=%d, "
+ "max_mem_allowed=%d\n", ioc->name, raid_device->handle,
+ num_pds, MPT_MAX_WARPDRIVE_PDS);
+ kfree(vol_pg0);
+ return;
+ }
+ for (count = 0; count < num_pds; count++) {
+ if (mpt3sas_config_get_phys_disk_pg0(ioc, &mpi_reply,
+ &pd_pg0, MPI2_PHYSDISK_PGAD_FORM_PHYSDISKNUM,
+ vol_pg0->PhysDisk[count].PhysDiskNum) ||
+ pd_pg0.DevHandle == MPT3SAS_INVALID_DEVICE_HANDLE) {
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is "
+ "disabled for the drive with handle(0x%04x) member"
+ "handle retrieval failed for member number=%d\n",
+ ioc->name, raid_device->handle,
+ vol_pg0->PhysDisk[count].PhysDiskNum);
+ goto out_error;
+ }
+ /* Disable direct I/O if member drive lba exceeds 4 bytes */
+ dev_max_lba = le64_to_cpu(pd_pg0.DeviceMaxLBA);
+ if (dev_max_lba >> 32) {
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is "
+ "disabled for the drive with handle(0x%04x) member"
+ " handle (0x%04x) unsupported max lba 0x%016llx\n",
+ ioc->name, raid_device->handle,
+ le16_to_cpu(pd_pg0.DevHandle),
+ (unsigned long long)dev_max_lba);
+ goto out_error;
+ }
+
+ raid_device->pd_handle[count] = le16_to_cpu(pd_pg0.DevHandle);
+ }
+
+ /*
+ * Assumption for WD: Direct I/O is not supported if the volume is
+ * not RAID0
+ */
+ if (raid_device->volume_type != MPI2_RAID_VOL_TYPE_RAID0) {
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is disabled "
+ "for the drive with handle(0x%04x): type=%d, "
+ "s_sz=%uK, blk_size=%u\n", ioc->name,
+ raid_device->handle, raid_device->volume_type,
+ (le32_to_cpu(vol_pg0->StripeSize) *
+ le16_to_cpu(vol_pg0->BlockSize)) / 1024,
+ le16_to_cpu(vol_pg0->BlockSize));
+ goto out_error;
+ }
+
+ stripe_sz = le32_to_cpu(vol_pg0->StripeSize);
+ stripe_exp = find_first_bit(&stripe_sz, 32);
+ if (stripe_exp == 32) {
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is disabled "
+ "for the drive with handle(0x%04x) invalid stripe sz %uK\n",
+ ioc->name, raid_device->handle,
+ (le32_to_cpu(vol_pg0->StripeSize) *
+ le16_to_cpu(vol_pg0->BlockSize)) / 1024);
+ goto out_error;
+ }
+ raid_device->stripe_exponent = stripe_exp;
+ block_sz = le16_to_cpu(vol_pg0->BlockSize);
+ block_exp = find_first_bit(&block_sz, 16);
+ if (block_exp == 16) {
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is disabled "
+ "for the drive with handle(0x%04x) invalid block sz %u\n",
+ ioc->name, raid_device->handle,
+ le16_to_cpu(vol_pg0->BlockSize));
+ goto out_error;
+ }
+ raid_device->block_exponent = block_exp;
+ raid_device->direct_io_enabled = 1;
+
+ pr_info(MPT3SAS_FMT "WarpDrive : Direct IO is Enabled for the drive"
+ " with handle(0x%04x)\n", ioc->name, raid_device->handle);
+ /*
+ * WARPDRIVE: Though the following fields are not used for direct IO,
+ * stored for future purpose:
+ */
+ raid_device->max_lba = le64_to_cpu(vol_pg0->MaxLBA);
+ raid_device->stripe_sz = le32_to_cpu(vol_pg0->StripeSize);
+ raid_device->block_sz = le16_to_cpu(vol_pg0->BlockSize);
+
+
+ kfree(vol_pg0);
+ return;
+
+out_error:
+ raid_device->direct_io_enabled = 0;
+ for (count = 0; count < num_pds; count++)
+ raid_device->pd_handle[count] = 0;
+ kfree(vol_pg0);
+ return;
+}
+
+/**
+ * _scsih_scsi_direct_io_get - returns direct io flag
+ * @ioc: per adapter object
+ * @smid: system request message index
+ *
+ * Returns the smid stored scmd pointer.
+ */
+static inline u8
+_scsih_scsi_direct_io_get(struct MPT3SAS_ADAPTER *ioc, u16 smid)
+{
+ return ioc->scsi_lookup[smid - 1].direct_io;
+}
+
+/**
+ * _scsih_scsi_direct_io_set - sets direct io flag
+ * @ioc: per adapter object
+ * @smid: system request message index
+ * @direct_io: Zero or non-zero value to set in the direct_io flag
+ *
+ * Returns Nothing.
+ */
+static inline void
+_scsih_scsi_direct_io_set(struct MPT3SAS_ADAPTER *ioc, u16 smid, u8 direct_io)
+{
+ ioc->scsi_lookup[smid - 1].direct_io = direct_io;
+}
+
+/**
+ * _scsih_setup_direct_io - setup MPI request for WARPDRIVE Direct I/O
+ * @ioc: per adapter object
+ * @scmd: pointer to scsi command object
+ * @raid_device: pointer to raid device data structure
+ * @mpi_request: pointer to the SCSI_IO reqest message frame
+ * @smid: system request message index
+ *
+ * Returns nothing
+ */
+static void
+_scsih_setup_direct_io(struct MPT3SAS_ADAPTER *ioc, struct scsi_cmnd *scmd,
+ struct _raid_device *raid_device, Mpi2SCSIIORequest_t *mpi_request,
+ u16 smid)
+{
+ sector_t v_lba, p_lba, stripe_off, stripe_unit, column, io_size;
+ u32 stripe_sz, stripe_exp;
+ u8 num_pds, cmd = scmd->cmnd[0];
+
+ if (cmd != READ_10 && cmd != WRITE_10 &&
+ cmd != READ_16 && cmd != WRITE_16)
+ return;
+
+ if (cmd == READ_10 || cmd == WRITE_10)
+ v_lba = get_unaligned_be32(&mpi_request->CDB.CDB32[2]);
+ else
+ v_lba = get_unaligned_be64(&mpi_request->CDB.CDB32[2]);
+
+ io_size = scsi_bufflen(scmd) >> raid_device->block_exponent;
+
+ if (v_lba + io_size - 1 > raid_device->max_lba)
+ return;
+
+ stripe_sz = raid_device->stripe_sz;
+ stripe_exp = raid_device->stripe_exponent;
+ stripe_off = v_lba & (stripe_sz - 1);
+
+ /* Return unless IO falls within a stripe */
+ if (stripe_off + io_size > stripe_sz)
+ return;
+
+ num_pds = raid_device->num_pds;
+ p_lba = v_lba >> stripe_exp;
+ stripe_unit = p_lba / num_pds;
+ column = p_lba % num_pds;
+ p_lba = (stripe_unit << stripe_exp) + stripe_off;
+ mpi_request->DevHandle = cpu_to_le16(raid_device->pd_handle[column]);
+
+ if (cmd == READ_10 || cmd == WRITE_10)
+ put_unaligned_be32(lower_32_bits(p_lba),
+ &mpi_request->CDB.CDB32[2]);
+ else
+ put_unaligned_be64(p_lba, &mpi_request->CDB.CDB32[2]);
+
+ _scsih_scsi_direct_io_set(ioc, smid, 1);
+}
desc = "Device Status Change";
break;
case MPI2_EVENT_IR_OPERATION_STATUS:
- desc = "IR Operation Status";
+ if (!ioc->hide_ir_msg)
+ desc = "IR Operation Status";
break;
case MPI2_EVENT_SAS_DISCOVERY:
{
desc = "SAS Enclosure Device Status Change";
break;
case MPI2_EVENT_IR_VOLUME:
- desc = "IR Volume";
+ if (!ioc->hide_ir_msg)
+ desc = "IR Volume";
break;
case MPI2_EVENT_IR_PHYSICAL_DISK:
- desc = "IR Physical Disk";
+ if (!ioc->hide_ir_msg)
+ desc = "IR Physical Disk";
break;
case MPI2_EVENT_IR_CONFIGURATION_CHANGE_LIST:
- desc = "IR Configuration Change List";
+ if (!ioc->hide_ir_msg)
+ desc = "IR Configuration Change List";
break;
case MPI2_EVENT_LOG_ENTRY_ADDED:
- desc = "Log Entry Added";
+ if (!ioc->hide_ir_msg)
+ desc = "Log Entry Added";
break;
case MPI2_EVENT_TEMP_THRESHOLD:
desc = "Temperature Threshold";
originator_str = "PL";
break;
case 2:
- originator_str = "IR";
+ if (!ioc->hide_ir_msg)
+ originator_str = "IR";
+ else
+ originator_str = "WarpDrive";
break;
}
}
wmb();
+ if (ioc->is_warpdrive) {
+ writel(reply_q->reply_post_host_index,
+ ioc->reply_post_host_index[msix_index]);
+ atomic_dec(&reply_q->busy);
+ return IRQ_HANDLED;
+ }
/* Update Reply Post Host Index.
* For those HBA's which support combined reply queue feature
}
ioc->scsi_lookup[i].cb_idx = 0xFF;
ioc->scsi_lookup[i].scmd = NULL;
+ ioc->scsi_lookup[i].direct_io = 0;
list_add(&ioc->scsi_lookup[i].tracker_list, &ioc->free_list);
spin_unlock_irqrestore(&ioc->scsi_lookup_lock, flags);
pr_info("), ");
pr_info("Capabilities=(");
- if (ioc->facts.IOCCapabilities &
+ if (!ioc->hide_ir_msg) {
+ if (ioc->facts.IOCCapabilities &
MPI2_IOCFACTS_CAPABILITY_INTEGRATED_RAID) {
pr_info("Raid");
i++;
+ }
}
if (ioc->facts.IOCCapabilities & MPI2_IOCFACTS_CAPABILITY_TLR) {
u32 reply_address;
u16 smid;
struct _tr_list *delayed_tr, *delayed_tr_next;
+ u8 hide_flag;
struct adapter_reply_queue *reply_q;
long reply_post_free;
u32 reply_post_free_sz, index = 0;
ioc->scsi_lookup[i].cb_idx = 0xFF;
ioc->scsi_lookup[i].smid = smid;
ioc->scsi_lookup[i].scmd = NULL;
+ ioc->scsi_lookup[i].direct_io = 0;
list_add_tail(&ioc->scsi_lookup[i].tracker_list,
&ioc->free_list);
}
if (ioc->is_driver_loading) {
+
+ if (ioc->is_warpdrive && ioc->manu_pg10.OEMIdentifier
+ == 0x80) {
+ hide_flag = (u8) (
+ le32_to_cpu(ioc->manu_pg10.OEMSpecificFlags0) &
+ MFG_PAGE10_HIDE_SSDS_MASK);
+ if (hide_flag != MFG_PAGE10_HIDE_SSDS_MASK)
+ ioc->mfg_pg10_hide_flag = hide_flag;
+ }
+
ioc->wait_for_discovery_to_complete =
_base_determine_wait_on_discovery(ioc);
goto out_free_resources;
}
+ if (ioc->is_warpdrive) {
+ ioc->reply_post_host_index = kcalloc(ioc->cpu_msix_table_sz,
+ sizeof(resource_size_t *), GFP_KERNEL);
+ if (!ioc->reply_post_host_index) {
+ dfailprintk(ioc, pr_info(MPT3SAS_FMT "allocation "
+ "for cpu_msix_table failed!!!\n", ioc->name));
+ r = -ENOMEM;
+ goto out_free_resources;
+ }
+ }
+
ioc->rdpq_array_enable_assigned = 0;
ioc->dma_mask = 0;
r = mpt3sas_base_map_resources(ioc);
if (r)
goto out_free_resources;
+ if (ioc->is_warpdrive) {
+ ioc->reply_post_host_index[0] = (resource_size_t __iomem *)
+ &ioc->chip->ReplyPostHostIndex;
+
+ for (i = 1; i < ioc->cpu_msix_table_sz; i++)
+ ioc->reply_post_host_index[i] =
+ (resource_size_t __iomem *)
+ ((u8 __iomem *)&ioc->chip->Doorbell + (0x4000 + ((i - 1)
+ * 4)));
+ }
pci_set_drvdata(ioc->pdev, ioc->shost);
r = _base_get_ioc_facts(ioc, CAN_SLEEP);
_base_release_memory_pools(ioc);
pci_set_drvdata(ioc->pdev, NULL);
kfree(ioc->cpu_msix_table);
+ if (ioc->is_warpdrive)
+ kfree(ioc->reply_post_host_index);
kfree(ioc->pd_handles);
kfree(ioc->blocking_handles);
kfree(ioc->tm_cmds.reply);
_base_release_memory_pools(ioc);
pci_set_drvdata(ioc->pdev, NULL);
kfree(ioc->cpu_msix_table);
+ if (ioc->is_warpdrive)
+ kfree(ioc->reply_post_host_index);
kfree(ioc->pd_handles);
kfree(ioc->blocking_handles);
kfree(ioc->pfacts);
*/
#define MPT3SAS_FMT "%s: "
+/*
+ * WarpDrive Specific Log codes
+ */
+
+#define MPT2_WARPDRIVE_LOGENTRY (0x8002)
+#define MPT2_WARPDRIVE_LC_SSDT (0x41)
+#define MPT2_WARPDRIVE_LC_SSDLW (0x43)
+#define MPT2_WARPDRIVE_LC_SSDLF (0x44)
+#define MPT2_WARPDRIVE_LC_BRMF (0x4D)
+
/*
* per target private data
*/
* struct MPT3SAS_TARGET - starget private hostdata
* @starget: starget object
* @sas_address: target sas address
+ * @raid_device: raid_device pointer to access volume data
* @handle: device handle
* @num_luns: number luns
* @flags: MPT_TARGET_FLAGS_XXX flags
struct MPT3SAS_TARGET {
struct scsi_target *starget;
u64 sas_address;
+ struct _raid_device *raid_device;
u16 handle;
int num_luns;
u32 flags;
#define MPT_DEVICE_FLAGS_INIT 0x01
#define MPT_DEVICE_TLR_ON 0x02
+#define MFG_PAGE10_HIDE_SSDS_MASK (0x00000003)
+#define MFG_PAGE10_HIDE_ALL_DISKS (0x00)
+#define MFG_PAGE10_EXPOSE_ALL_DISKS (0x01)
+#define MFG_PAGE10_HIDE_IF_VOL_PRESENT (0x02)
+
/**
* struct MPT3SAS_DEVICE - sdev private hostdata
* @sas_target: starget private hostdata
* @sdev: scsi device struct (volumes are single lun)
* @wwid: unique identifier for the volume
* @handle: device handle
+ * @block_size: Block size of the volume
* @id: target id
* @channel: target channel
* @volume_type: the raid level
* @num_pds: number of hidden raid components
* @responding: used in _scsih_raid_device_mark_responding
* @percent_complete: resync percent complete
+ * @direct_io_enabled: Whether direct io to PDs are allowed or not
+ * @stripe_exponent: X where 2powX is the stripe sz in blocks
+ * @block_exponent: X where 2powX is the block sz in bytes
+ * @max_lba: Maximum number of LBA in the volume
+ * @stripe_sz: Stripe Size of the volume
+ * @device_info: Device info of the volume member disk
+ * @pd_handle: Array of handles of the physical drives for direct I/O in le16
*/
#define MPT_MAX_WARPDRIVE_PDS 8
struct _raid_device {
struct scsi_device *sdev;
u64 wwid;
u16 handle;
+ u16 block_sz;
int id;
int channel;
u8 volume_type;
u8 num_pds;
u8 responding;
u8 percent_complete;
+ u8 direct_io_enabled;
+ u8 stripe_exponent;
+ u8 block_exponent;
+ u64 max_lba;
+ u32 stripe_sz;
u32 device_info;
+ u16 pd_handle[MPT_MAX_WARPDRIVE_PDS];
};
/**
* @smid: system message id
* @scmd: scsi request pointer
* @cb_idx: callback index
+ * @direct_io: To indicate whether I/O is direct (WARPDRIVE)
* @tracker_list: list of free request (ioc->free_list)
*/
struct scsiio_tracker {
u16 smid;
struct scsi_cmnd *scmd;
u8 cb_idx;
+ u8 direct_io;
struct list_head chain_list;
struct list_head tracker_list;
};
u16 msix_vector_count;
u8 *cpu_msix_table;
u16 cpu_msix_table_sz;
+ resource_size_t __iomem **reply_post_host_index;
u32 ioc_reset_count;
MPT3SAS_FLUSH_RUNNING_CMDS schedule_dead_ioc_flush_running_cmds;
u32 non_operational_loop;
u32 diagnostic_flags[MPI2_DIAG_BUF_TYPE_COUNT];
u32 ring_buffer_offset;
u32 ring_buffer_sz;
+ u8 is_warpdrive;
+ u8 hide_ir_msg;
+ u8 mfg_pg10_hide_flag;
+ u8 hide_drives;
spinlock_t diag_trigger_lock;
u8 diag_trigger_active;
struct SL_WH_MASTER_TRIGGER_T diag_trigger_master;
strcat(karg.driver_version, "-");
switch (ioc->hba_mpi_version_belonged) {
case MPI2_VERSION:
- karg.adapter_type = MPT2_IOCTL_INTERFACE_SAS2;
+ if (ioc->is_warpdrive)
+ karg.adapter_type = MPT2_IOCTL_INTERFACE_SAS2_SSS6200;
+ else
+ karg.adapter_type = MPT2_IOCTL_INTERFACE_SAS2;
strcat(karg.driver_version, MPT2SAS_DRIVER_VERSION);
break;
case MPI25_VERSION:
#define MPT2_IOCTL_INTERFACE_FC_IP (0x02)
#define MPT2_IOCTL_INTERFACE_SAS (0x03)
#define MPT2_IOCTL_INTERFACE_SAS2 (0x04)
+#define MPT2_IOCTL_INTERFACE_SAS2_SSS6200 (0x05)
#define MPT3_IOCTL_INTERFACE_SAS3 (0x06)
#define MPT2_IOCTL_VERSION_LENGTH (32)
#include <linux/interrupt.h>
#include <linux/aer.h>
#include <linux/raid_class.h>
+#include <asm/unaligned.h>
#include "mpt3sas_base.h"
static u8 _scsih_check_for_pending_tm(struct MPT3SAS_ADAPTER *ioc, u16 smid);
+#ifdef SCSI_MPT2SAS
+static void _scsih_disable_ddio(struct MPT3SAS_ADAPTER *ioc);
+static u8 _scsih_get_num_volumes(struct MPT3SAS_ADAPTER *ioc);
+static void
+_scsih_init_warpdrive_properties(struct MPT3SAS_ADAPTER *ioc,
+ struct _raid_device *raid_device);
+static inline u8
+_scsih_scsi_direct_io_get(struct MPT3SAS_ADAPTER *ioc, u16 smid);
+static inline void
+_scsih_scsi_direct_io_set(struct MPT3SAS_ADAPTER *ioc, u16 smid, u8 direct_io);
+static void
+_scsih_setup_direct_io(struct MPT3SAS_ADAPTER *ioc, struct scsi_cmnd *scmd,
+ struct _raid_device *raid_device, Mpi2SCSIIORequest_t *mpi_request,
+ u16 smid);
+#endif
/* global parameters */
LIST_HEAD(mpt3sas_ioc_list);
sas_target_priv_data->handle = raid_device->handle;
sas_target_priv_data->sas_address = raid_device->wwid;
sas_target_priv_data->flags |= MPT_TARGET_FLAGS_VOLUME;
- raid_device->starget = starget;
+ sas_target_priv_data->raid_device = raid_device;
+ if (ioc->is_warpdrive)
+ raid_device->starget = starget;
}
spin_unlock_irqrestore(&ioc->raid_device_lock, flags);
return 0;
scsih_is_raid(struct device *dev)
{
struct scsi_device *sdev = to_scsi_device(dev);
+ struct MPT3SAS_ADAPTER *ioc = shost_priv(sdev->host);
+ if (ioc->is_warpdrive)
+ return 0;
return (sdev->channel == RAID_CHANNEL) ? 1 : 0;
}
percent_complete = 0;
handle = 0;
+ if (ioc->is_warpdrive)
+ goto out;
+
spin_lock_irqsave(&ioc->raid_device_lock, flags);
raid_device = _scsih_raid_device_find_by_id(ioc, sdev->id,
sdev->channel);
return 0;
}
-
-
/**
* _scsih_enable_tlr - setting TLR flags
* @ioc: per adapter object
return 1;
}
+#ifdef SCSI_MPT2SAS
+ /*
+ * WARPDRIVE: Initialize the required data for Direct IO
+ */
+ _scsih_init_warpdrive_properties(ioc, raid_device);
+#endif
/* RAID Queue Depth Support
* IS volume = underlying qdepth of drive type, either
break;
}
- sdev_printk(KERN_INFO, sdev,
- "%s: handle(0x%04x), wwid(0x%016llx), pd_count(%d), type(%s)\n",
- r_level, raid_device->handle,
- (unsigned long long)raid_device->wwid,
- raid_device->num_pds, ds);
-
+ if (!ioc->hide_ir_msg)
+ sdev_printk(KERN_INFO, sdev,
+ "%s: handle(0x%04x), wwid(0x%016llx),"
+ " pd_count(%d), type(%s)\n",
+ r_level, raid_device->handle,
+ (unsigned long long)raid_device->wwid,
+ raid_device->num_pds, ds);
scsih_change_queue_depth(sdev, qdepth);
-/* raid transport support */
- _scsih_set_level(sdev, raid_device->volume_type);
+ /* raid transport support */
+ if (!ioc->is_warpdrive)
+ _scsih_set_level(sdev, raid_device->volume_type);
return 0;
}
if (!priv_target)
return;
- device_str = "volume";
+ if (ioc->hide_ir_msg)
+ device_str = "WarpDrive";
+ else
+ device_str = "volume";
scsi_print_command(scmd);
if (priv_target->flags & MPT_TARGET_FLAGS_VOLUME) {
a = 0;
b = 0;
+ if (ioc->is_warpdrive)
+ return;
+
/* Volume Resets for Deleted or Removed */
element = (Mpi2EventIrConfigElement_t *)&event_data->ConfigElement[0];
for (i = 0; i < event_data->NumElements; i++, element++) {
}
+
/**
* scsih_qcmd - main scsi request entry point
* @scmd: pointer to scsi command object
struct MPT3SAS_ADAPTER *ioc = shost_priv(shost);
struct MPT3SAS_DEVICE *sas_device_priv_data;
struct MPT3SAS_TARGET *sas_target_priv_data;
+#ifdef SCSI_MPT2SAS
+ struct _raid_device *raid_device;
+#endif
Mpi2SCSIIORequest_t *mpi_request;
u32 mpi_control;
u16 smid;
/* set tags */
mpi_control |= MPI2_SCSIIO_CONTROL_SIMPLEQ;
- if ((sas_device_priv_data->flags & MPT_DEVICE_TLR_ON) &&
+ /* Make sure Device is not raid volume.
+ * We do not expose raid functionality to upper layer for warpdrive.
+ */
+ if (!ioc->is_warpdrive && !scsih_is_raid(&scmd->device->sdev_gendev)
+ && (sas_device_priv_data->flags & MPT_DEVICE_TLR_ON) &&
scmd->cmd_len != 32)
mpi_control |= MPI2_SCSIIO_CONTROL_TLR_ON;
} else
ioc->build_zero_len_sge(ioc, &mpi_request->SGL);
+#ifdef SCSI_MPT2SAS
+ raid_device = sas_target_priv_data->raid_device;
+ if (raid_device && raid_device->direct_io_enabled)
+ _scsih_setup_direct_io(ioc, scmd, raid_device, mpi_request,
+ smid);
+#endif
+
if (likely(mpi_request->Function == MPI2_FUNCTION_SCSI_IO_REQUEST)) {
#ifndef SCSI_MPT2SAS
if (sas_target_priv_data->flags & MPT_TARGET_FASTPATH_IO) {
mpt3sas_base_put_smid_fast_path(ioc, smid, handle);
} else
#endif
- mpt3sas_base_put_smid_scsi_io(ioc, smid, handle);
+ mpt3sas_base_put_smid_scsi_io(ioc, smid,
+ le16_to_cpu(mpi_request->DevHandle));
} else
mpt3sas_base_put_smid_default(ioc, smid);
return 0;
if (!priv_target)
return;
- device_str = "volume";
+ if (ioc->hide_ir_msg)
+ device_str = "WarpDrive";
+ else
+ device_str = "volume";
if (log_info == 0x31170000)
return;
u32 log_info;
struct MPT3SAS_DEVICE *sas_device_priv_data;
u32 response_code = 0;
+#ifdef SCSI_MPT2SAS
+ unsigned long flags;
+#endif
mpi_reply = mpt3sas_base_get_reply_virt_addr(ioc, reply);
scmd = _scsih_scsi_lookup_get_clear(ioc, smid);
}
ioc_status = le16_to_cpu(mpi_reply->IOCStatus);
+#ifdef SCSI_MPT2SAS
+ /*
+ * WARPDRIVE: If direct_io is set then it is directIO,
+ * the failed direct I/O should be redirected to volume
+ */
+ if (_scsih_scsi_direct_io_get(ioc, smid) &&
+ ((ioc_status & MPI2_IOCSTATUS_MASK)
+ != MPI2_IOCSTATUS_SCSI_TASK_TERMINATED)) {
+ spin_lock_irqsave(&ioc->scsi_lookup_lock, flags);
+ ioc->scsi_lookup[smid - 1].scmd = scmd;
+ spin_unlock_irqrestore(&ioc->scsi_lookup_lock, flags);
+ _scsih_scsi_direct_io_set(ioc, smid, 0);
+ memcpy(mpi_request->CDB.CDB32, scmd->cmnd, scmd->cmd_len);
+ mpi_request->DevHandle =
+ cpu_to_le16(sas_device_priv_data->sas_target->handle);
+ mpt3sas_base_put_smid_scsi_io(ioc, smid,
+ sas_device_priv_data->sas_target->handle);
+ return 0;
+ }
+#endif
/* turning off TLR */
scsi_state = mpi_reply->SCSIState;
if (scsi_state & MPI2_SCSI_STATE_RESPONSE_INFO_VALID)
le32_to_cpu(mpi_reply->ResponseInfo) & 0xFF;
if (!sas_device_priv_data->tlr_snoop_check) {
sas_device_priv_data->tlr_snoop_check++;
- if ((sas_device_priv_data->flags & MPT_DEVICE_TLR_ON) &&
+ if (!ioc->is_warpdrive &&
+ !scsih_is_raid(&scmd->device->sdev_gendev) &&
+ (sas_device_priv_data->flags & MPT_DEVICE_TLR_ON) &&
response_code == MPI2_SCSITASKMGMT_RSP_INVALID_FRAME)
sas_device_priv_data->flags &=
~MPT_DEVICE_TLR_ON;
sas_target_priv_data->handle =
MPT3SAS_INVALID_DEVICE_HANDLE;
}
- mpt3sas_transport_port_remove(ioc,
+
+ if (!ioc->hide_drives)
+ mpt3sas_transport_port_remove(ioc,
sas_device->sas_address,
sas_device->sas_address_parent);
(Mpi2EventDataIrConfigChangeList_t *)
fw_event->event_data;
- if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK)
+ if ((ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK) &&
+ (!ioc->hide_ir_msg))
_scsih_sas_ir_config_change_event_debug(ioc, event_data);
foreign_config = (le32_to_cpu(event_data->Flags) &
#endif
return;
}
+
for (i = 0; i < event_data->NumElements; i++, element++) {
switch (element->ReasonCode) {
le16_to_cpu(element->VolDevHandle));
break;
case MPI2_EVENT_IR_CHANGE_RC_PD_CREATED:
- _scsih_sas_pd_hide(ioc, element);
+ if (!ioc->is_warpdrive)
+ _scsih_sas_pd_hide(ioc, element);
break;
case MPI2_EVENT_IR_CHANGE_RC_PD_DELETED:
- _scsih_sas_pd_expose(ioc, element);
+ if (!ioc->is_warpdrive)
+ _scsih_sas_pd_expose(ioc, element);
break;
case MPI2_EVENT_IR_CHANGE_RC_HIDE:
- _scsih_sas_pd_add(ioc, element);
+ if (!ioc->is_warpdrive)
+ _scsih_sas_pd_add(ioc, element);
break;
case MPI2_EVENT_IR_CHANGE_RC_UNHIDE:
- _scsih_sas_pd_delete(ioc, element);
+ if (!ioc->is_warpdrive)
+ _scsih_sas_pd_delete(ioc, element);
break;
}
}
handle = le16_to_cpu(event_data->VolDevHandle);
state = le32_to_cpu(event_data->NewValue);
- dewtprintk(ioc, pr_info(MPT3SAS_FMT
- "%s: handle(0x%04x), old(0x%08x), new(0x%08x)\n",
- ioc->name, __func__, handle,
- le32_to_cpu(event_data->PreviousValue), state));
+ if (!ioc->hide_ir_msg)
+ dewtprintk(ioc, pr_info(MPT3SAS_FMT
+ "%s: handle(0x%04x), old(0x%08x), new(0x%08x)\n",
+ ioc->name, __func__, handle,
+ le32_to_cpu(event_data->PreviousValue), state));
switch (state) {
case MPI2_RAID_VOL_STATE_MISSING:
case MPI2_RAID_VOL_STATE_FAILED:
handle = le16_to_cpu(event_data->PhysDiskDevHandle);
state = le32_to_cpu(event_data->NewValue);
- dewtprintk(ioc, pr_info(MPT3SAS_FMT
- "%s: handle(0x%04x), old(0x%08x), new(0x%08x)\n",
- ioc->name, __func__, handle,
+ if (!ioc->hide_ir_msg)
+ dewtprintk(ioc, pr_info(MPT3SAS_FMT
+ "%s: handle(0x%04x), old(0x%08x), new(0x%08x)\n",
+ ioc->name, __func__, handle,
le32_to_cpu(event_data->PreviousValue), state));
+
switch (state) {
case MPI2_RAID_PD_STATE_ONLINE:
case MPI2_RAID_PD_STATE_DEGRADED:
case MPI2_RAID_PD_STATE_OPTIMAL:
case MPI2_RAID_PD_STATE_HOT_SPARE:
- set_bit(handle, ioc->pd_handles);
+ if (!ioc->is_warpdrive)
+ set_bit(handle, ioc->pd_handles);
spin_lock_irqsave(&ioc->sas_device_lock, flags);
sas_device = _scsih_sas_device_find_by_handle(ioc, handle);
spin_unlock_irqrestore(&ioc->sas_device_lock, flags);
unsigned long flags;
u16 handle;
- if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK)
+ if ((ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK) &&
+ (!ioc->hide_ir_msg))
_scsih_sas_ir_operation_status_event_debug(ioc,
event_data);
_scsih_mark_responding_raid_device(struct MPT3SAS_ADAPTER *ioc, u64 wwid,
u16 handle)
{
- struct MPT3SAS_TARGET *sas_target_priv_data;
+ struct MPT3SAS_TARGET *sas_target_priv_data = NULL;
struct scsi_target *starget;
struct _raid_device *raid_device;
unsigned long flags;
starget_printk(KERN_INFO, raid_device->starget,
"handle(0x%04x), wwid(0x%016llx)\n", handle,
(unsigned long long)raid_device->wwid);
+
+#ifdef SCSI_MPT2SAS
+ /*
+ * WARPDRIVE: The handles of the PDs might have changed
+ * across the host reset so re-initialize the
+ * required data for Direct IO
+ */
+ _scsih_init_warpdrive_properties(ioc, raid_device);
+#endif
spin_lock_irqsave(&ioc->raid_device_lock, flags);
if (raid_device->handle == handle) {
spin_unlock_irqrestore(&ioc->raid_device_lock,
}
/* refresh the pd_handles */
+ if (!ioc->is_warpdrive) {
phys_disk_num = 0xFF;
memset(ioc->pd_handles, 0, ioc->pd_handles_sz);
while (!(mpt3sas_config_get_phys_disk_pg0(ioc, &mpi_reply,
handle = le16_to_cpu(pd_pg0.DevHandle);
set_bit(handle, ioc->pd_handles);
}
+ }
out:
pr_info(MPT3SAS_FMT "search for responding raid volumes: complete\n",
ioc->name);
(Mpi2EventDataIrVolume_t *)
mpi_reply->EventData);
break;
+ case MPI2_EVENT_LOG_ENTRY_ADDED:
+ {
+ Mpi2EventDataLogEntryAdded_t *log_entry;
+ u32 *log_code;
+
+ if (!ioc->is_warpdrive)
+ break;
+
+ log_entry = (Mpi2EventDataLogEntryAdded_t *)
+ mpi_reply->EventData;
+ log_code = (u32 *)log_entry->LogData;
+ if (le16_to_cpu(log_entry->LogEntryQualifier)
+ != MPT2_WARPDRIVE_LOGENTRY)
+ break;
+
+ switch (le32_to_cpu(*log_code)) {
+ case MPT2_WARPDRIVE_LC_SSDT:
+ pr_warn(MPT3SAS_FMT "WarpDrive Warning: "
+ "IO Throttling has occurred in the WarpDrive "
+ "subsystem. Check WarpDrive documentation for "
+ "additional details.\n", ioc->name);
+ break;
+ case MPT2_WARPDRIVE_LC_SSDLW:
+ pr_warn(MPT3SAS_FMT "WarpDrive Warning: "
+ "Program/Erase Cycles for the WarpDrive subsystem "
+ "in degraded range. Check WarpDrive documentation "
+ "for additional details.\n", ioc->name);
+ break;
+ case MPT2_WARPDRIVE_LC_SSDLF:
+ pr_err(MPT3SAS_FMT "WarpDrive Fatal Error: "
+ "There are no Program/Erase Cycles for the "
+ "WarpDrive subsystem. The storage device will be "
+ "in read-only mode. Check WarpDrive documentation "
+ "for additional details.\n", ioc->name);
+ break;
+ case MPT2_WARPDRIVE_LC_BRMF:
+ pr_err(MPT3SAS_FMT "WarpDrive Fatal Error: "
+ "The Backup Rail Monitor has failed on the "
+ "WarpDrive subsystem. Check WarpDrive "
+ "documentation for additional details.\n",
+ ioc->name);
+ break;
+ }
+
+ break;
+ }
case MPI2_EVENT_SAS_DEVICE_STATUS_CHANGE:
case MPI2_EVENT_IR_OPERATION_STATUS:
case MPI2_EVENT_SAS_DISCOVERY:
mpi_request->Function = MPI2_FUNCTION_RAID_ACTION;
mpi_request->Action = MPI2_RAID_ACTION_SYSTEM_SHUTDOWN_INITIATED;
- pr_info(MPT3SAS_FMT "IR shutdown (sending)\n", ioc->name);
+ if (!ioc->hide_ir_msg)
+ pr_info(MPT3SAS_FMT "IR shutdown (sending)\n", ioc->name);
init_completion(&ioc->scsih_cmds.done);
mpt3sas_base_put_smid_default(ioc, smid);
wait_for_completion_timeout(&ioc->scsih_cmds.done, 10*HZ);
if (ioc->scsih_cmds.status & MPT3_CMD_REPLY_VALID) {
mpi_reply = ioc->scsih_cmds.reply;
- pr_info(MPT3SAS_FMT
- "IR shutdown (complete): ioc_status(0x%04x), loginfo(0x%08x)\n",
- ioc->name, le16_to_cpu(mpi_reply->IOCStatus),
- le32_to_cpu(mpi_reply->IOCLogInfo));
+ if (!ioc->hide_ir_msg)
+ pr_info(MPT3SAS_FMT "IR shutdown "
+ "(complete): ioc_status(0x%04x), loginfo(0x%08x)\n",
+ ioc->name, le16_to_cpu(mpi_reply->IOCStatus),
+ le32_to_cpu(mpi_reply->IOCLogInfo));
}
out:
list_move_tail(&sas_device->list, &ioc->sas_device_list);
spin_unlock_irqrestore(&ioc->sas_device_lock, flags);
+ if (ioc->hide_drives)
+ return;
if (!mpt3sas_transport_port_add(ioc, handle,
sas_address_parent)) {
_scsih_sas_device_remove(ioc, sas_device);
list_for_each_entry_safe(sas_device, next, &ioc->sas_device_init_list,
list) {
+ if (ioc->hide_drives)
+ return;
+
if (!mpt3sas_transport_port_add(ioc, sas_device->handle,
sas_device->sas_address_parent)) {
list_del(&sas_device->list);
_scsih_determine_hba_mpi_version(struct MPT3SAS_ADAPTER *ioc) {
switch (ioc->pdev->device) {
+ case MPI2_MFGPAGE_DEVID_SSS6200:
+ ioc->is_warpdrive = 1;
+ ioc->hide_ir_msg = 1;
case MPI2_MFGPAGE_DEVID_SAS2004:
case MPI2_MFGPAGE_DEVID_SAS2008:
case MPI2_MFGPAGE_DEVID_SAS2108_1:
ioc->msix96_vector = 1;
break;
}
+
+ if ((ioc->pdev->device != MPI2_MFGPAGE_DEVID_SSS6200) &&
+ (ioc->hba_mpi_version_belonged == MPI2_VERSION))
+ ioc->mfg_pg10_hide_flag = MFG_PAGE10_EXPOSE_ALL_DISKS;
}
/**
list_add_tail(&ioc->list, &mpt3sas_ioc_list);
ioc->shost = shost;
ioc->id = mpt_ids++;
-
ioc->pdev = pdev;
ioc->scsi_io_cb_idx = scsi_io_cb_idx;
ioc->tm_cb_idx = tm_cb_idx;
rv = -ENODEV;
goto out_attach_fail;
}
+
+#ifdef SCSI_MPT2SAS
+ if (ioc->is_warpdrive) {
+ if (ioc->mfg_pg10_hide_flag == MFG_PAGE10_EXPOSE_ALL_DISKS)
+ ioc->hide_drives = 0;
+ else if (ioc->mfg_pg10_hide_flag == MFG_PAGE10_HIDE_ALL_DISKS)
+ ioc->hide_drives = 1;
+ else {
+ if (_scsih_get_num_volumes(ioc))
+ ioc->hide_drives = 1;
+ else
+ ioc->hide_drives = 0;
+ }
+ } else
+ ioc->hide_drives = 0;
+#endif
+
rv = scsi_add_host(shost, &pdev->dev);
if (rv) {
pr_err(MPT3SAS_FMT "failure at %s:%d/%s()!\n",
raid_class_release(mpt3sas_raid_template);
sas_release_transport(mpt3sas_transport_template);
}
+
+#ifdef SCSI_MPT2SAS
+#include "../mpt2sas/mpt2sas_warpdrive.c"
+#endif