In MediaTek PCIe gen3 bindings, "clocks" accepts a range of 1-6 clocks
across all SoCs. But in practice, each SoC requires a particular number of
clocks as defined in "clock-names", and the length of "clocks" and
"clock-names" can be inconsistent with current bindings.
For example:
- MT8188, MT8192 and MT8195 all require 6 clocks, while the bindings
accept 4-6 clocks.
- MT7986 requires 4 clocks, while the bindings accept 4-6 clocks.
Update minItems and maxItems properties for individual SoCs as needed to
only accept the correct number of clocks.
Fixes:
c6abd0eadec6 ("dt-bindings: PCI: mediatek-gen3: Add support for Airoha EN7581")
Link: https://lore.kernel.org/r/20240925110044.3678055-3-fshao@chromium.org
Signed-off-by: Fei Shao <fshao@chromium.org>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
Reviewed-by: Krzysztof Kozlowski <krzk@kernel.org>
then:
properties:
clocks:
- minItems: 4
+ minItems: 6
clock-names:
items:
then:
properties:
clocks:
- minItems: 4
+ minItems: 6
clock-names:
items:
properties:
clocks:
minItems: 4
+ maxItems: 4
clock-names:
items: