v_ret, (u8 *)vfres, sizeof(*vfres));
}
-/**
- * ice_is_supported_port_vlan_proto - make sure the vlan_proto is supported
- * @hw: hardware structure used to check the VLAN mode
- * @vlan_proto: VLAN TPID being checked
- *
- * If the device is configured in Double VLAN Mode (DVM), then both ETH_P_8021Q
- * and ETH_P_8021AD are supported. If the device is configured in Single VLAN
- * Mode (SVM), then only ETH_P_8021Q is supported.
- */
-static bool
-ice_is_supported_port_vlan_proto(struct ice_hw *hw, u16 vlan_proto)
-{
- bool is_supported = false;
-
- switch (vlan_proto) {
- case ETH_P_8021Q:
- is_supported = true;
- break;
- case ETH_P_8021AD:
- if (ice_is_dvm_ena(hw))
- is_supported = true;
- break;
- }
-
- return is_supported;
-}
-
-/**
- * ice_set_vf_port_vlan
- * @netdev: network interface device structure
- * @vf_id: VF identifier
- * @vlan_id: VLAN ID being set
- * @qos: priority setting
- * @vlan_proto: VLAN protocol
- *
- * program VF Port VLAN ID and/or QoS
- */
-int
-ice_set_vf_port_vlan(struct net_device *netdev, int vf_id, u16 vlan_id, u8 qos,
- __be16 vlan_proto)
-{
- struct ice_pf *pf = ice_netdev_to_pf(netdev);
- u16 local_vlan_proto = ntohs(vlan_proto);
- struct device *dev;
- struct ice_vf *vf;
- int ret;
-
- dev = ice_pf_to_dev(pf);
-
- if (vlan_id >= VLAN_N_VID || qos > 7) {
- dev_err(dev, "Invalid Port VLAN parameters for VF %d, ID %d, QoS %d\n",
- vf_id, vlan_id, qos);
- return -EINVAL;
- }
-
- if (!ice_is_supported_port_vlan_proto(&pf->hw, local_vlan_proto)) {
- dev_err(dev, "VF VLAN protocol 0x%04x is not supported\n",
- local_vlan_proto);
- return -EPROTONOSUPPORT;
- }
-
- vf = ice_get_vf_by_id(pf, vf_id);
- if (!vf)
- return -EINVAL;
-
- ret = ice_check_vf_ready_for_cfg(vf);
- if (ret)
- goto out_put_vf;
-
- if (ice_vf_get_port_vlan_prio(vf) == qos &&
- ice_vf_get_port_vlan_tpid(vf) == local_vlan_proto &&
- ice_vf_get_port_vlan_id(vf) == vlan_id) {
- /* duplicate request, so just return success */
- dev_dbg(dev, "Duplicate port VLAN %u, QoS %u, TPID 0x%04x request\n",
- vlan_id, qos, local_vlan_proto);
- ret = 0;
- goto out_put_vf;
- }
-
- mutex_lock(&vf->cfg_lock);
-
- vf->port_vlan_info = ICE_VLAN(local_vlan_proto, vlan_id, qos);
- if (ice_vf_is_port_vlan_ena(vf))
- dev_info(dev, "Setting VLAN %u, QoS %u, TPID 0x%04x on VF %d\n",
- vlan_id, qos, local_vlan_proto, vf_id);
- else
- dev_info(dev, "Clearing port VLAN on VF %d\n", vf_id);
-
- ice_vc_reset_vf(vf);
- mutex_unlock(&vf->cfg_lock);
-
-out_put_vf:
- ice_put_vf(vf);
- return ret;
-}
-
/**
* ice_vf_vlan_offload_ena - determine if capabilities support VLAN offloads
* @caps: VF driver negotiated capabilities
return ret;
}
+/**
+ * ice_is_supported_port_vlan_proto - make sure the vlan_proto is supported
+ * @hw: hardware structure used to check the VLAN mode
+ * @vlan_proto: VLAN TPID being checked
+ *
+ * If the device is configured in Double VLAN Mode (DVM), then both ETH_P_8021Q
+ * and ETH_P_8021AD are supported. If the device is configured in Single VLAN
+ * Mode (SVM), then only ETH_P_8021Q is supported.
+ */
+static bool
+ice_is_supported_port_vlan_proto(struct ice_hw *hw, u16 vlan_proto)
+{
+ bool is_supported = false;
+
+ switch (vlan_proto) {
+ case ETH_P_8021Q:
+ is_supported = true;
+ break;
+ case ETH_P_8021AD:
+ if (ice_is_dvm_ena(hw))
+ is_supported = true;
+ break;
+ }
+
+ return is_supported;
+}
+
+/**
+ * ice_set_vf_port_vlan
+ * @netdev: network interface device structure
+ * @vf_id: VF identifier
+ * @vlan_id: VLAN ID being set
+ * @qos: priority setting
+ * @vlan_proto: VLAN protocol
+ *
+ * program VF Port VLAN ID and/or QoS
+ */
+int
+ice_set_vf_port_vlan(struct net_device *netdev, int vf_id, u16 vlan_id, u8 qos,
+ __be16 vlan_proto)
+{
+ struct ice_pf *pf = ice_netdev_to_pf(netdev);
+ u16 local_vlan_proto = ntohs(vlan_proto);
+ struct device *dev;
+ struct ice_vf *vf;
+ int ret;
+
+ dev = ice_pf_to_dev(pf);
+
+ if (vlan_id >= VLAN_N_VID || qos > 7) {
+ dev_err(dev, "Invalid Port VLAN parameters for VF %d, ID %d, QoS %d\n",
+ vf_id, vlan_id, qos);
+ return -EINVAL;
+ }
+
+ if (!ice_is_supported_port_vlan_proto(&pf->hw, local_vlan_proto)) {
+ dev_err(dev, "VF VLAN protocol 0x%04x is not supported\n",
+ local_vlan_proto);
+ return -EPROTONOSUPPORT;
+ }
+
+ vf = ice_get_vf_by_id(pf, vf_id);
+ if (!vf)
+ return -EINVAL;
+
+ ret = ice_check_vf_ready_for_cfg(vf);
+ if (ret)
+ goto out_put_vf;
+
+ if (ice_vf_get_port_vlan_prio(vf) == qos &&
+ ice_vf_get_port_vlan_tpid(vf) == local_vlan_proto &&
+ ice_vf_get_port_vlan_id(vf) == vlan_id) {
+ /* duplicate request, so just return success */
+ dev_dbg(dev, "Duplicate port VLAN %u, QoS %u, TPID 0x%04x request\n",
+ vlan_id, qos, local_vlan_proto);
+ ret = 0;
+ goto out_put_vf;
+ }
+
+ mutex_lock(&vf->cfg_lock);
+
+ vf->port_vlan_info = ICE_VLAN(local_vlan_proto, vlan_id, qos);
+ if (ice_vf_is_port_vlan_ena(vf))
+ dev_info(dev, "Setting VLAN %u, QoS %u, TPID 0x%04x on VF %d\n",
+ vlan_id, qos, local_vlan_proto, vf_id);
+ else
+ dev_info(dev, "Clearing port VLAN on VF %d\n", vf_id);
+
+ ice_vc_reset_vf(vf);
+ mutex_unlock(&vf->cfg_lock);
+
+out_put_vf:
+ ice_put_vf(vf);
+ return ret;
+}
+
/**
* ice_print_vf_rx_mdd_event - print VF Rx malicious driver detect event
* @vf: pointer to the VF structure