PWM on/off registers are limited to UINT_MAX. However the state period
and duty_cycle fields are ns values of type u64. There is no reason to
limit them to UINT_MAX.
Reported-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Reviewed-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Reviewed-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Baruch Siach <baruch@tkos.co.il>
Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
regmap_read(mvpwm->regs, mvebu_pwmreg_blink_on_duration(mvpwm), &u);
val = (unsigned long long) u * NSEC_PER_SEC;
val = DIV_ROUND_UP_ULL(val, mvpwm->clk_rate);
- if (val > UINT_MAX)
- state->duty_cycle = UINT_MAX;
- else if (val)
+ if (val)
state->duty_cycle = val;
else
state->duty_cycle = 1;
val += (unsigned long long) u; /* period = on + off duration */
val *= NSEC_PER_SEC;
val = DIV_ROUND_UP_ULL(val, mvpwm->clk_rate);
- if (val > UINT_MAX)
- state->period = UINT_MAX;
- else if (val)
+ if (val)
state->period = val;
else
state->period = 1;