ACPI / battery: fix wrong value of capacity_now reported when fully charged
authorJosef Gajdusek <atx@atx.name>
Tue, 17 Jun 2014 21:15:49 +0000 (23:15 +0200)
committerRafael J. Wysocki <rafael.j.wysocki@intel.com>
Mon, 7 Jul 2014 21:37:06 +0000 (23:37 +0200)
It seems that some batteries (noticed on DELL JYPJ136) assume
capacity_now = design_capacity when fully charged. This causes
reported capacity to suddenly jump to >full_charge_capacity (and that
means capacity reported to userspace is >100% and incorrect)
values after 99%. This patch detects capacity_now > full_charge_capacity,
notifies userspace (unless it is the known bug where capacity_now ==
design_capacity) and trims the value to full_charge_capacity.

Signed-off-by: Josef Gajdusek <atx@atx.name>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
drivers/acpi/battery.c

index bc0b286..130f513 100644 (file)
@@ -535,6 +535,20 @@ static int acpi_battery_get_state(struct acpi_battery *battery)
                        " invalid.\n");
        }
 
+       /*
+        * When fully charged, some batteries wrongly report
+        * capacity_now = design_capacity instead of = full_charge_capacity
+        */
+       if (battery->capacity_now > battery->full_charge_capacity
+           && battery->full_charge_capacity != ACPI_BATTERY_VALUE_UNKNOWN) {
+               battery->capacity_now = battery->full_charge_capacity;
+               if (battery->capacity_now != battery->design_capacity)
+                       printk_once(KERN_WARNING FW_BUG
+                               "battery: reported current charge level (%d) "
+                               "is higher than reported maximum charge level (%d).\n",
+                               battery->capacity_now, battery->full_charge_capacity);
+       }
+
        if (test_bit(ACPI_BATTERY_QUIRK_PERCENTAGE_CAPACITY, &battery->flags)
            && battery->capacity_now >= 0 && battery->capacity_now <= 100)
                battery->capacity_now = (battery->capacity_now *