hwmon: (pmbus) Improve auto-detection of temperature status register
authorGuenter Roeck <guenter.roeck@ericsson.com>
Sun, 3 Jul 2011 20:08:03 +0000 (13:08 -0700)
committerGuenter Roeck <guenter.roeck@ericsson.com>
Sun, 10 Jul 2011 15:54:29 +0000 (08:54 -0700)
It is possible that a PMBus device supports the READ_TEMPERATURE2 and/or
READ_TEMPERATURE3 registers but does not support READ_TEMPERATURE1.
Improve temperature status register detection to address this condition.

Reported-by: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Cc: stable@kernel.org # 2.6.39+
drivers/hwmon/pmbus.c

index 931d940..9b1f0c3 100644 (file)
@@ -59,16 +59,17 @@ static void pmbus_find_sensor_groups(struct i2c_client *client,
                if (pmbus_check_byte_register(client, 0, PMBUS_STATUS_FAN_34))
                        info->func[0] |= PMBUS_HAVE_STATUS_FAN34;
        }
-       if (pmbus_check_word_register(client, 0, PMBUS_READ_TEMPERATURE_1)) {
+       if (pmbus_check_word_register(client, 0, PMBUS_READ_TEMPERATURE_1))
                info->func[0] |= PMBUS_HAVE_TEMP;
-               if (pmbus_check_byte_register(client, 0,
-                                             PMBUS_STATUS_TEMPERATURE))
-                       info->func[0] |= PMBUS_HAVE_STATUS_TEMP;
-       }
        if (pmbus_check_word_register(client, 0, PMBUS_READ_TEMPERATURE_2))
                info->func[0] |= PMBUS_HAVE_TEMP2;
        if (pmbus_check_word_register(client, 0, PMBUS_READ_TEMPERATURE_3))
                info->func[0] |= PMBUS_HAVE_TEMP3;
+       if (info->func[0] & (PMBUS_HAVE_TEMP | PMBUS_HAVE_TEMP2
+                            | PMBUS_HAVE_TEMP3)
+           && pmbus_check_byte_register(client, 0,
+                                        PMBUS_STATUS_TEMPERATURE))
+                       info->func[0] |= PMBUS_HAVE_STATUS_TEMP;
 
        /* Sensors detected on all pages */
        for (page = 0; page < info->pages; page++) {