arm64: dts: qcom: pm8998: Add pm8998 thermal zone
authorMatthias Kaehlcke <mka@chromium.org>
Tue, 31 Jul 2018 18:59:17 +0000 (11:59 -0700)
committerAndy Gross <andy.gross@linaro.org>
Thu, 13 Sep 2018 19:37:18 +0000 (14:37 -0500)
The thermal zone uses spmi-temp-alarm as sensor, the trip points
correspond to the PMIC thermal stages 1 and 2. The critical trip
point at 125°C disables the partial PMIC shutdown at stage 2.

Without an IIO input the sensor only reports a limited number of
temperatures:

- 37°C for temperatures below 105°C
- 107°C for temperatures >= 105°C and < 125°C
- 127°C for temperatures >= 125°C

(the numbers correspond to a stage 1 threshold of 105°C)

Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
Reviewed-by: Douglas Anderson <dianders@chromium.org>
Signed-off-by: Andy Gross <andy.gross@linaro.org>
arch/arm64/boot/dts/qcom/pm8998.dtsi

index 8f20e33..048f19f 100644 (file)
@@ -5,7 +5,31 @@
 #include <dt-bindings/input/linux-event-codes.h>
 #include <dt-bindings/interrupt-controller/irq.h>
 #include <dt-bindings/spmi/spmi.h>
+#include <dt-bindings/thermal/thermal.h>
 
+/ {
+       thermal-zones {
+               pm8998 {
+                       polling-delay-passive = <250>;
+                       polling-delay = <1000>;
+
+                       thermal-sensors = <&pm8998_temp>;
+
+                       trips {
+                               pm8998_alert0: pm8998-alert0 {
+                                       temperature = <105000>;
+                                       hysteresis = <2000>;
+                                       type = "passive";
+                               };
+                               pm8998_crit: pm8998-crit {
+                                       temperature = <125000>;
+                                       hysteresis = <2000>;
+                                       type = "critical";
+                               };
+                       };
+               };
+       };
+};
 
 &spmi_bus {