Add new compatible ti,am62-eqep for TI K3 devices. If a device
uses this compatible, require power-domains property.
Since there is only one functional and interface clock for eqep,
clock-names is not really required, so removed from required
section, make it optional for ti,am3352-eqep compatible, and
update the example.
The clock-name also changed for TI K3 SoCs so do not allow
clock-names property for the new compatible.
Signed-off-by: Judith Mendez <jm@ti.com>
Acked-by: Conor Dooley <conor.dooley@microchip.com>
Reviewed-by: David Lechner <david@lechnology.com>
Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Link: https://lore.kernel.org/r/20240612135538.2447938-2-jm@ti.com
Signed-off-by: William Breathitt Gray <wbg@kernel.org>
properties:
compatible:
- const: ti,am3352-eqep
+ enum:
+ - ti,am3352-eqep
+ - ti,am62-eqep
reg:
maxItems: 1
maxItems: 1
clocks:
- description: The clock that determines the SYSCLKOUT rate for the eQEP
- peripheral.
+ description: The functional and interface clock that determines the clock
+ rate for the eQEP peripheral.
maxItems: 1
clock-names:
const: sysclkout
+ power-domains:
+ maxItems: 1
+
+allOf:
+ - if:
+ properties:
+ compatible:
+ contains:
+ enum:
+ - ti,am62-eqep
+ then:
+ properties:
+ clock-names: false
+
+ required:
+ - power-domains
+
required:
- compatible
- reg
- interrupts
- clocks
- - clock-names
additionalProperties: false
compatible = "ti,am3352-eqep";
reg = <0x180 0x80>;
clocks = <&l4ls_gclk>;
- clock-names = "sysclkout";
interrupts = <79>;
};