Add the POWER_SUPPLY_PROP_CHARGE_NOW attribute to allow user to get
current battery capacity (uAh) to do measurement.
Signed-off-by: Baolin Wang <baolin.wang7@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
val->intval = data->total_cap * 1000;
break;
val->intval = data->total_cap * 1000;
break;
+ case POWER_SUPPLY_PROP_CHARGE_NOW:
+ ret = sc27xx_fgu_get_clbcnt(data, &value);
+ if (ret)
+ goto error;
+
+ value = DIV_ROUND_CLOSEST(value * 10,
+ 36 * SC27XX_FGU_SAMPLE_HZ);
+ val->intval = sc27xx_fgu_adc_to_current(data, value);
+
+ break;
+
default:
ret = -EINVAL;
break;
default:
ret = -EINVAL;
break;
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN,
POWER_SUPPLY_PROP_CALIBRATE,
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN,
POWER_SUPPLY_PROP_CALIBRATE,
+ POWER_SUPPLY_PROP_CHARGE_NOW
};
static const struct power_supply_desc sc27xx_fgu_desc = {
};