thermal/drivers/tsens: Allow configuring min and max trips

IPQ8074 and IPQ6018 dont support negative trip temperatures and support
up to 204 degrees C as the max trip temperature.

So, instead of always setting the -40 as min and 120 degrees C as max
allow it to be configured as part of the features.

Signed-off-by: Robert Marko <robimarko@gmail.com>
Reviewed-by: Bjorn Andersson <bjorn.andersson@linaro.org>
Link: https://lore.kernel.org/r/20220818220245.338396-3-robimarko@gmail.com
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
drivers/thermal/qcom/tsens-8960.c
drivers/thermal/qcom/tsens-v0_1.c
drivers/thermal/qcom/tsens-v1.c
drivers/thermal/qcom/tsens-v2.c
drivers/thermal/qcom/tsens.c