scsi: smartpqi: Fix NUMA node not updated during init
authorMike McGowen <Mike.McGowen@microchip.com>
Tue, 1 Feb 2022 21:48:58 +0000 (15:48 -0600)
committerMartin K. Petersen <martin.petersen@oracle.com>
Tue, 8 Feb 2022 04:38:35 +0000 (23:38 -0500)
commitc52efc9238569038242e28f247546bb5b04dc8a1
treed3ab08836ad4e293536bc559482f3d735015560d
parent00598b056aa6d46c7a6819efa850ec9d0d690d76
scsi: smartpqi: Fix NUMA node not updated during init

Correct NUMA node association when calling pqi_pci_probe().

In the function pqi_pci_probe(), the driver makes an OS call to get the
NUMA node associated with a controller. If the call returns that there is
no associated node, the driver attempts to set it to node 0. The problem is
that a different local variable (cp_node) was being used to do this, but
the original local variable (node) was still being used in the call to
pqi_alloc_ctrl_info().

The value of "node" is not updated if the conditional after the call to
dev_to_node() evaluates to TRUE.

Link: https://lore.kernel.org/r/164375213850.440833.5243014942807747074.stgit@brunhilda.pdev.net
Reviewed-by: Kevin Barnett <kevin.barnett@microchip.com>
Reviewed-by: Scott Teel <scott.teel@microchip.com>
Signed-off-by: Mike McGowen <Mike.McGowen@microchip.com>
Signed-off-by: Don Brace <don.brace@microchip.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
drivers/scsi/smartpqi/smartpqi_init.c