serial: 8250_bcm7271: UART errors after resuming from S2
authorAl Cooper <alcooperx@gmail.com>
Wed, 1 Dec 2021 20:14:02 +0000 (15:14 -0500)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 3 Dec 2021 13:14:49 +0000 (14:14 +0100)
commit9cabe26e65a893afd5846908aa393bd283ab6609
tree216255317e4d46dbf1746adfb3f8369724f278a6
parentbb1201d4b38ec67bd9a871cf86b0cc10f28b15b5
serial: 8250_bcm7271: UART errors after resuming from S2

There is a small window in time during resume where the hardware
flow control signal RTS can be asserted (which allows a sender to
resume sending data to the UART) but the baud rate has not yet
been restored. This will cause corrupted data and FRAMING, OVERRUN
and BREAK errors. This is happening because the MCTRL register is
shadowed in uart_port struct and is later used during resume to set
the MCTRL register during both serial8250_do_startup() and
uart_resume_port(). Unfortunately, serial8250_do_startup()
happens before the UART baud rate is restored. The fix is to clear
the shadowed mctrl value at the end of suspend and restore it at the
end of resume.