microblaze: reset: Provide a power off handler through an unaligned PC
microblaze is missing a generic architecture-wide power off mechanism.
To enable KUnit for microblaze it is necessary for KUnit to shut down
the machine in a way that QEMU will recognize. The machines emulated by
QEMU do not provide machine-specific power off functionality which could
be used.
However at least the petalogix-s3adsp1800 machine will abort if an
unaligned instruction is executed. An ugly message will be printed but
that is not an issue for KUnit.
Make use of this to provide a power off handler.
Signed-off-by: Thomas Weißschuh <linux@weissschuh.net>
Tested-by: David Gow <david@davidgow.net>
Link: https://patch.msgid.link/20260914-kunit-microblaze-v2-4-7d5756e858f8@weissschuh.net
Signed-off-by: Michal Simek <michal.simek@amd.com>