net: bgmac: enable master mode for BCM54210E and B50212E PHYs
authorRafał Miłecki <rafal@milecki.pl>
Thu, 12 Oct 2017 08:21:26 +0000 (10:21 +0200)
committerDavid S. Miller <davem@davemloft.net>
Fri, 13 Oct 2017 05:59:38 +0000 (22:59 -0700)
commit12acd136913ccdf394eeb2bc8686ff5505368119
treed104e37e5f425f6eeec2fbd8518d2a6d537fe1a0
parent2355a6546a053b1c16ebefd6ce1f0cccc00e1da5
net: bgmac: enable master mode for BCM54210E and B50212E PHYs

There are 4 very similar PHYs:
0x600d84a1: BCM54210E (rev B0)
0x600d84a2: BCM54210E (rev B1)
0x600d84a5: B50212E (rev B0)
0x600d84a6: B50212E (rev B1)
that need setting master mode manually. It's because they run in slave
mode by default with Automatic Slave/Master configuration disabled which
can lead to unreliable connection with massive ping loss.

So far it was reported for a board with BCM47189 SoC and B50212E B1 PHY
connected to the bgmac supported ethernet device. Telling PHY driver to
setup PHY properly solves this issue.

Signed-off-by: Rafał Miłecki <rafal@milecki.pl>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/broadcom/bgmac-bcma.c