config SIEMENS_SIMATIC_IPC_WDT
tristate "Siemens Simatic IPC Watchdog"
- depends on SIEMENS_SIMATIC_IPC
+ depends on SIEMENS_SIMATIC_IPC && PCI
+ default y
select WATCHDOG_CORE
- select P2SB
+ select P2SB if X86
help
This driver adds support for several watchdogs found in Industrial
PCs from Siemens.