if (irqstat & LTC3676_IRQSTAT_THERMAL_WARN) {
dev_warn(dev, "Over-temperature Warning\n");
event = REGULATOR_EVENT_OVER_TEMP;
- for (i = 0; i < LTC3676_NUM_REGULATORS; i++) {
- regulator_lock(ltc3676->regulators[i]);
+ for (i = 0; i < LTC3676_NUM_REGULATORS; i++)
regulator_notifier_call_chain(ltc3676->regulators[i],
event, NULL);
- regulator_unlock(ltc3676->regulators[i]);
- }
}
if (irqstat & LTC3676_IRQSTAT_UNDERVOLT_WARN) {
dev_info(dev, "Undervoltage Warning\n");
event = REGULATOR_EVENT_UNDER_VOLTAGE;
- for (i = 0; i < LTC3676_NUM_REGULATORS; i++) {
- regulator_lock(ltc3676->regulators[i]);
+ for (i = 0; i < LTC3676_NUM_REGULATORS; i++)
regulator_notifier_call_chain(ltc3676->regulators[i],
event, NULL);
- regulator_unlock(ltc3676->regulators[i]);
- }
}
/* Clear warning condition */
};
MODULE_DEVICE_TABLE(i2c, ltc3676_i2c_id);
-static const struct of_device_id ltc3676_of_match[] = {
+static const struct of_device_id __maybe_unused ltc3676_of_match[] = {
{ .compatible = "lltc,ltc3676" },
{ },
};