#define MLXSW_THERMAL_ASIC_TEMP_NORM 75000 /* 75C */
#define MLXSW_THERMAL_ASIC_TEMP_HIGH 85000 /* 85C */
#define MLXSW_THERMAL_ASIC_TEMP_HOT 105000 /* 105C */
-#define MLXSW_THERMAL_ASIC_TEMP_CRIT 110000 /* 110C */
+#define MLXSW_THERMAL_ASIC_TEMP_CRIT 140000 /* 140C */
#define MLXSW_THERMAL_HYSTERESIS_TEMP 5000 /* 5C */
#define MLXSW_THERMAL_MODULE_TEMP_SHIFT (MLXSW_THERMAL_HYSTERESIS_TEMP * 2)
#define MLXSW_THERMAL_ZONE_MAX_NAME 16
if (err)
return err;
+ if (crit_temp > emerg_temp) {
+ dev_warn(dev, "%s : Critical threshold %d is above emergency threshold %d\n",
+ tz->tzdev->type, crit_temp, emerg_temp);
+ return 0;
+ }
+
/* According to the system thermal requirements, the thermal zones are
* defined with four trip points. The critical and emergency
* temperature thresholds, provided by QSFP module are set as "active"
tz->trips[MLXSW_THERMAL_TEMP_TRIP_NORM].temp = crit_temp;
tz->trips[MLXSW_THERMAL_TEMP_TRIP_HIGH].temp = crit_temp;
tz->trips[MLXSW_THERMAL_TEMP_TRIP_HOT].temp = emerg_temp;
- if (emerg_temp > crit_temp)
- tz->trips[MLXSW_THERMAL_TEMP_TRIP_CRIT].temp = emerg_temp +
+ tz->trips[MLXSW_THERMAL_TEMP_TRIP_CRIT].temp = emerg_temp +
MLXSW_THERMAL_MODULE_TEMP_SHIFT;
- else
- tz->trips[MLXSW_THERMAL_TEMP_TRIP_CRIT].temp = emerg_temp;
return 0;
}