Merge tag 'rproc-v6.8' of git://git.kernel.org/pub/scm/linux/kernel/git/remoteproc...
[linux-2.6-microblaze.git] / include / linux / sched / topology.h
1 /* SPDX-License-Identifier: GPL-2.0 */
2 #ifndef _LINUX_SCHED_TOPOLOGY_H
3 #define _LINUX_SCHED_TOPOLOGY_H
4
5 #include <linux/topology.h>
6
7 #include <linux/sched/idle.h>
8
9 /*
10  * sched-domains (multiprocessor balancing) declarations:
11  */
12 #ifdef CONFIG_SMP
13
14 /* Generate SD flag indexes */
15 #define SD_FLAG(name, mflags) __##name,
16 enum {
17         #include <linux/sched/sd_flags.h>
18         __SD_FLAG_CNT,
19 };
20 #undef SD_FLAG
21 /* Generate SD flag bits */
22 #define SD_FLAG(name, mflags) name = 1 << __##name,
23 enum {
24         #include <linux/sched/sd_flags.h>
25 };
26 #undef SD_FLAG
27
28 #ifdef CONFIG_SCHED_DEBUG
29
30 struct sd_flag_debug {
31         unsigned int meta_flags;
32         char *name;
33 };
34 extern const struct sd_flag_debug sd_flag_debug[];
35
36 #endif
37
38 #ifdef CONFIG_SCHED_SMT
39 static inline int cpu_smt_flags(void)
40 {
41         return SD_SHARE_CPUCAPACITY | SD_SHARE_PKG_RESOURCES;
42 }
43 #endif
44
45 #ifdef CONFIG_SCHED_CLUSTER
46 static inline int cpu_cluster_flags(void)
47 {
48         return SD_CLUSTER | SD_SHARE_PKG_RESOURCES;
49 }
50 #endif
51
52 #ifdef CONFIG_SCHED_MC
53 static inline int cpu_core_flags(void)
54 {
55         return SD_SHARE_PKG_RESOURCES;
56 }
57 #endif
58
59 #ifdef CONFIG_NUMA
60 static inline int cpu_numa_flags(void)
61 {
62         return SD_NUMA;
63 }
64 #endif
65
66 extern int arch_asym_cpu_priority(int cpu);
67
68 struct sched_domain_attr {
69         int relax_domain_level;
70 };
71
72 #define SD_ATTR_INIT    (struct sched_domain_attr) {    \
73         .relax_domain_level = -1,                       \
74 }
75
76 extern int sched_domain_level_max;
77
78 struct sched_group;
79
80 struct sched_domain_shared {
81         atomic_t        ref;
82         atomic_t        nr_busy_cpus;
83         int             has_idle_cores;
84         int             nr_idle_scan;
85 };
86
87 struct sched_domain {
88         /* These fields must be setup */
89         struct sched_domain __rcu *parent;      /* top domain must be null terminated */
90         struct sched_domain __rcu *child;       /* bottom domain must be null terminated */
91         struct sched_group *groups;     /* the balancing groups of the domain */
92         unsigned long min_interval;     /* Minimum balance interval ms */
93         unsigned long max_interval;     /* Maximum balance interval ms */
94         unsigned int busy_factor;       /* less balancing by factor if busy */
95         unsigned int imbalance_pct;     /* No balance until over watermark */
96         unsigned int cache_nice_tries;  /* Leave cache hot tasks for # tries */
97         unsigned int imb_numa_nr;       /* Nr running tasks that allows a NUMA imbalance */
98
99         int nohz_idle;                  /* NOHZ IDLE status */
100         int flags;                      /* See SD_* */
101         int level;
102
103         /* Runtime fields. */
104         unsigned long last_balance;     /* init to jiffies. units in jiffies */
105         unsigned int balance_interval;  /* initialise to 1. units in ms. */
106         unsigned int nr_balance_failed; /* initialise to 0 */
107
108         /* idle_balance() stats */
109         u64 max_newidle_lb_cost;
110         unsigned long last_decay_max_lb_cost;
111
112 #ifdef CONFIG_SCHEDSTATS
113         /* load_balance() stats */
114         unsigned int lb_count[CPU_MAX_IDLE_TYPES];
115         unsigned int lb_failed[CPU_MAX_IDLE_TYPES];
116         unsigned int lb_balanced[CPU_MAX_IDLE_TYPES];
117         unsigned int lb_imbalance[CPU_MAX_IDLE_TYPES];
118         unsigned int lb_gained[CPU_MAX_IDLE_TYPES];
119         unsigned int lb_hot_gained[CPU_MAX_IDLE_TYPES];
120         unsigned int lb_nobusyg[CPU_MAX_IDLE_TYPES];
121         unsigned int lb_nobusyq[CPU_MAX_IDLE_TYPES];
122
123         /* Active load balancing */
124         unsigned int alb_count;
125         unsigned int alb_failed;
126         unsigned int alb_pushed;
127
128         /* SD_BALANCE_EXEC stats */
129         unsigned int sbe_count;
130         unsigned int sbe_balanced;
131         unsigned int sbe_pushed;
132
133         /* SD_BALANCE_FORK stats */
134         unsigned int sbf_count;
135         unsigned int sbf_balanced;
136         unsigned int sbf_pushed;
137
138         /* try_to_wake_up() stats */
139         unsigned int ttwu_wake_remote;
140         unsigned int ttwu_move_affine;
141         unsigned int ttwu_move_balance;
142 #endif
143 #ifdef CONFIG_SCHED_DEBUG
144         char *name;
145 #endif
146         union {
147                 void *private;          /* used during construction */
148                 struct rcu_head rcu;    /* used during destruction */
149         };
150         struct sched_domain_shared *shared;
151
152         unsigned int span_weight;
153         /*
154          * Span of all CPUs in this domain.
155          *
156          * NOTE: this field is variable length. (Allocated dynamically
157          * by attaching extra space to the end of the structure,
158          * depending on how many CPUs the kernel has booted up with)
159          */
160         unsigned long span[];
161 };
162
163 static inline struct cpumask *sched_domain_span(struct sched_domain *sd)
164 {
165         return to_cpumask(sd->span);
166 }
167
168 extern void partition_sched_domains_locked(int ndoms_new,
169                                            cpumask_var_t doms_new[],
170                                            struct sched_domain_attr *dattr_new);
171
172 extern void partition_sched_domains(int ndoms_new, cpumask_var_t doms_new[],
173                                     struct sched_domain_attr *dattr_new);
174
175 /* Allocate an array of sched domains, for partition_sched_domains(). */
176 cpumask_var_t *alloc_sched_domains(unsigned int ndoms);
177 void free_sched_domains(cpumask_var_t doms[], unsigned int ndoms);
178
179 bool cpus_share_cache(int this_cpu, int that_cpu);
180 bool cpus_share_resources(int this_cpu, int that_cpu);
181
182 typedef const struct cpumask *(*sched_domain_mask_f)(int cpu);
183 typedef int (*sched_domain_flags_f)(void);
184
185 #define SDTL_OVERLAP    0x01
186
187 struct sd_data {
188         struct sched_domain *__percpu *sd;
189         struct sched_domain_shared *__percpu *sds;
190         struct sched_group *__percpu *sg;
191         struct sched_group_capacity *__percpu *sgc;
192 };
193
194 struct sched_domain_topology_level {
195         sched_domain_mask_f mask;
196         sched_domain_flags_f sd_flags;
197         int                 flags;
198         int                 numa_level;
199         struct sd_data      data;
200 #ifdef CONFIG_SCHED_DEBUG
201         char                *name;
202 #endif
203 };
204
205 extern void __init set_sched_topology(struct sched_domain_topology_level *tl);
206
207 #ifdef CONFIG_SCHED_DEBUG
208 # define SD_INIT_NAME(type)             .name = #type
209 #else
210 # define SD_INIT_NAME(type)
211 #endif
212
213 #else /* CONFIG_SMP */
214
215 struct sched_domain_attr;
216
217 static inline void
218 partition_sched_domains_locked(int ndoms_new, cpumask_var_t doms_new[],
219                                struct sched_domain_attr *dattr_new)
220 {
221 }
222
223 static inline void
224 partition_sched_domains(int ndoms_new, cpumask_var_t doms_new[],
225                         struct sched_domain_attr *dattr_new)
226 {
227 }
228
229 static inline bool cpus_share_cache(int this_cpu, int that_cpu)
230 {
231         return true;
232 }
233
234 static inline bool cpus_share_resources(int this_cpu, int that_cpu)
235 {
236         return true;
237 }
238
239 #endif  /* !CONFIG_SMP */
240
241 #if defined(CONFIG_ENERGY_MODEL) && defined(CONFIG_CPU_FREQ_GOV_SCHEDUTIL)
242 extern void rebuild_sched_domains_energy(void);
243 #else
244 static inline void rebuild_sched_domains_energy(void)
245 {
246 }
247 #endif
248
249 #ifndef arch_scale_cpu_capacity
250 /**
251  * arch_scale_cpu_capacity - get the capacity scale factor of a given CPU.
252  * @cpu: the CPU in question.
253  *
254  * Return: the CPU scale factor normalized against SCHED_CAPACITY_SCALE, i.e.
255  *
256  *             max_perf(cpu)
257  *      ----------------------------- * SCHED_CAPACITY_SCALE
258  *      max(max_perf(c) : c \in CPUs)
259  */
260 static __always_inline
261 unsigned long arch_scale_cpu_capacity(int cpu)
262 {
263         return SCHED_CAPACITY_SCALE;
264 }
265 #endif
266
267 #ifndef arch_scale_thermal_pressure
268 static __always_inline
269 unsigned long arch_scale_thermal_pressure(int cpu)
270 {
271         return 0;
272 }
273 #endif
274
275 #ifndef arch_update_thermal_pressure
276 static __always_inline
277 void arch_update_thermal_pressure(const struct cpumask *cpus,
278                                   unsigned long capped_frequency)
279 { }
280 #endif
281
282 #ifndef arch_scale_freq_ref
283 static __always_inline
284 unsigned int arch_scale_freq_ref(int cpu)
285 {
286         return 0;
287 }
288 #endif
289
290 static inline int task_node(const struct task_struct *p)
291 {
292         return cpu_to_node(task_cpu(p));
293 }
294
295 #endif /* _LINUX_SCHED_TOPOLOGY_H */