Merge remote-tracking branch 'origin/master' into perf/core
[linux-2.6-microblaze.git] / drivers / rtc / rtc-fsl-ftm-alarm.c
1 // SPDX-License-Identifier: GPL-2.0+
2 /*
3  * Freescale FlexTimer Module (FTM) alarm device driver.
4  *
5  * Copyright 2014 Freescale Semiconductor, Inc.
6  * Copyright 2019-2020 NXP
7  *
8  */
9
10 #include <linux/device.h>
11 #include <linux/err.h>
12 #include <linux/interrupt.h>
13 #include <linux/io.h>
14 #include <linux/of_address.h>
15 #include <linux/of_irq.h>
16 #include <linux/platform_device.h>
17 #include <linux/of.h>
18 #include <linux/of_device.h>
19 #include <linux/module.h>
20 #include <linux/fsl/ftm.h>
21 #include <linux/rtc.h>
22 #include <linux/time.h>
23 #include <linux/acpi.h>
24 #include <linux/pm_wakeirq.h>
25
26 #define FTM_SC_CLK(c)           ((c) << FTM_SC_CLK_MASK_SHIFT)
27
28 /*
29  * Select Fixed frequency clock (32KHz) as clock source
30  * of FlexTimer Module
31  */
32 #define FTM_SC_CLKS_FIXED_FREQ  0x02
33 #define FIXED_FREQ_CLK          32000
34
35 /* Select 128 (2^7) as divider factor */
36 #define MAX_FREQ_DIV            (1 << FTM_SC_PS_MASK)
37
38 /* Maximum counter value in FlexTimer's CNT registers */
39 #define MAX_COUNT_VAL           0xffff
40
41 struct ftm_rtc {
42         struct rtc_device *rtc_dev;
43         void __iomem *base;
44         bool big_endian;
45         u32 alarm_freq;
46 };
47
48 static inline u32 rtc_readl(struct ftm_rtc *dev, u32 reg)
49 {
50         if (dev->big_endian)
51                 return ioread32be(dev->base + reg);
52         else
53                 return ioread32(dev->base + reg);
54 }
55
56 static inline void rtc_writel(struct ftm_rtc *dev, u32 reg, u32 val)
57 {
58         if (dev->big_endian)
59                 iowrite32be(val, dev->base + reg);
60         else
61                 iowrite32(val, dev->base + reg);
62 }
63
64 static inline void ftm_counter_enable(struct ftm_rtc *rtc)
65 {
66         u32 val;
67
68         /* select and enable counter clock source */
69         val = rtc_readl(rtc, FTM_SC);
70         val &= ~(FTM_SC_PS_MASK | FTM_SC_CLK_MASK);
71         val |= (FTM_SC_PS_MASK | FTM_SC_CLK(FTM_SC_CLKS_FIXED_FREQ));
72         rtc_writel(rtc, FTM_SC, val);
73 }
74
75 static inline void ftm_counter_disable(struct ftm_rtc *rtc)
76 {
77         u32 val;
78
79         /* disable counter clock source */
80         val = rtc_readl(rtc, FTM_SC);
81         val &= ~(FTM_SC_PS_MASK | FTM_SC_CLK_MASK);
82         rtc_writel(rtc, FTM_SC, val);
83 }
84
85 static inline void ftm_irq_acknowledge(struct ftm_rtc *rtc)
86 {
87         unsigned int timeout = 100;
88
89         /*
90          *Fix errata A-007728 for flextimer
91          *      If the FTM counter reaches the FTM_MOD value between
92          *      the reading of the TOF bit and the writing of 0 to
93          *      the TOF bit, the process of clearing the TOF bit
94          *      does not work as expected when FTMx_CONF[NUMTOF] != 0
95          *      and the current TOF count is less than FTMx_CONF[NUMTOF].
96          *      If the above condition is met, the TOF bit remains set.
97          *      If the TOF interrupt is enabled (FTMx_SC[TOIE] = 1),the
98          *      TOF interrupt also remains asserted.
99          *
100          *      Above is the errata discription
101          *
102          *      In one word: software clearing TOF bit not works when
103          *      FTMx_CONF[NUMTOF] was seted as nonzero and FTM counter
104          *      reaches the FTM_MOD value.
105          *
106          *      The workaround is clearing TOF bit until it works
107          *      (FTM counter doesn't always reache the FTM_MOD anyway),
108          *      which may cost some cycles.
109          */
110         while ((FTM_SC_TOF & rtc_readl(rtc, FTM_SC)) && timeout--)
111                 rtc_writel(rtc, FTM_SC, rtc_readl(rtc, FTM_SC) & (~FTM_SC_TOF));
112 }
113
114 static inline void ftm_irq_enable(struct ftm_rtc *rtc)
115 {
116         u32 val;
117
118         val = rtc_readl(rtc, FTM_SC);
119         val |= FTM_SC_TOIE;
120         rtc_writel(rtc, FTM_SC, val);
121 }
122
123 static inline void ftm_irq_disable(struct ftm_rtc *rtc)
124 {
125         u32 val;
126
127         val = rtc_readl(rtc, FTM_SC);
128         val &= ~FTM_SC_TOIE;
129         rtc_writel(rtc, FTM_SC, val);
130 }
131
132 static inline void ftm_reset_counter(struct ftm_rtc *rtc)
133 {
134         /*
135          * The CNT register contains the FTM counter value.
136          * Reset clears the CNT register. Writing any value to COUNT
137          * updates the counter with its initial value, CNTIN.
138          */
139         rtc_writel(rtc, FTM_CNT, 0x00);
140 }
141
142 static void ftm_clean_alarm(struct ftm_rtc *rtc)
143 {
144         ftm_counter_disable(rtc);
145
146         rtc_writel(rtc, FTM_CNTIN, 0x00);
147         rtc_writel(rtc, FTM_MOD, ~0U);
148
149         ftm_reset_counter(rtc);
150 }
151
152 static irqreturn_t ftm_rtc_alarm_interrupt(int irq, void *dev)
153 {
154         struct ftm_rtc *rtc = dev;
155
156         rtc_update_irq(rtc->rtc_dev, 1, RTC_IRQF | RTC_AF);
157
158         ftm_irq_acknowledge(rtc);
159         ftm_irq_disable(rtc);
160         ftm_clean_alarm(rtc);
161
162         return IRQ_HANDLED;
163 }
164
165 static int ftm_rtc_alarm_irq_enable(struct device *dev,
166                 unsigned int enabled)
167 {
168         struct ftm_rtc *rtc = dev_get_drvdata(dev);
169
170         if (enabled)
171                 ftm_irq_enable(rtc);
172         else
173                 ftm_irq_disable(rtc);
174
175         return 0;
176 }
177
178 /*
179  * Note:
180  *      The function is not really getting time from the RTC
181  *      since FlexTimer is not a RTC device, but we need to
182  *      get time to setup alarm, so we are using system time
183  *      for now.
184  */
185 static int ftm_rtc_read_time(struct device *dev, struct rtc_time *tm)
186 {
187         rtc_time64_to_tm(ktime_get_real_seconds(), tm);
188
189         return 0;
190 }
191
192 static int ftm_rtc_read_alarm(struct device *dev, struct rtc_wkalrm *alm)
193 {
194         return 0;
195 }
196
197 /*
198  * 1. Select fixed frequency clock (32KHz) as clock source;
199  * 2. Select 128 (2^7) as divider factor;
200  * So clock is 250 Hz (32KHz/128).
201  *
202  * 3. FlexTimer's CNT register is a 32bit register,
203  * but the register's 16 bit as counter value,it's other 16 bit
204  * is reserved.So minimum counter value is 0x0,maximum counter
205  * value is 0xffff.
206  * So max alarm value is 262 (65536 / 250) seconds
207  */
208 static int ftm_rtc_set_alarm(struct device *dev, struct rtc_wkalrm *alm)
209 {
210         time64_t alm_time;
211         unsigned long long cycle;
212         struct ftm_rtc *rtc = dev_get_drvdata(dev);
213
214         alm_time = rtc_tm_to_time64(&alm->time);
215
216         ftm_clean_alarm(rtc);
217         cycle = (alm_time - ktime_get_real_seconds()) * rtc->alarm_freq;
218         if (cycle > MAX_COUNT_VAL) {
219                 pr_err("Out of alarm range {0~262} seconds.\n");
220                 return -ERANGE;
221         }
222
223         ftm_irq_disable(rtc);
224
225         /*
226          * The counter increments until the value of MOD is reached,
227          * at which point the counter is reloaded with the value of CNTIN.
228          * The TOF (the overflow flag) bit is set when the FTM counter
229          * changes from MOD to CNTIN. So we should using the cycle - 1.
230          */
231         rtc_writel(rtc, FTM_MOD, cycle - 1);
232
233         ftm_counter_enable(rtc);
234         ftm_irq_enable(rtc);
235
236         return 0;
237
238 }
239
240 static const struct rtc_class_ops ftm_rtc_ops = {
241         .read_time              = ftm_rtc_read_time,
242         .read_alarm             = ftm_rtc_read_alarm,
243         .set_alarm              = ftm_rtc_set_alarm,
244         .alarm_irq_enable       = ftm_rtc_alarm_irq_enable,
245 };
246
247 static int ftm_rtc_probe(struct platform_device *pdev)
248 {
249         int irq;
250         int ret;
251         struct ftm_rtc *rtc;
252
253         rtc = devm_kzalloc(&pdev->dev, sizeof(*rtc), GFP_KERNEL);
254         if (unlikely(!rtc)) {
255                 dev_err(&pdev->dev, "cannot alloc memory for rtc\n");
256                 return -ENOMEM;
257         }
258
259         platform_set_drvdata(pdev, rtc);
260
261         rtc->rtc_dev = devm_rtc_allocate_device(&pdev->dev);
262         if (IS_ERR(rtc->rtc_dev))
263                 return PTR_ERR(rtc->rtc_dev);
264
265         rtc->base = devm_platform_ioremap_resource(pdev, 0);
266         if (IS_ERR(rtc->base)) {
267                 dev_err(&pdev->dev, "cannot ioremap resource for rtc\n");
268                 return PTR_ERR(rtc->base);
269         }
270
271         irq = platform_get_irq(pdev, 0);
272         if (irq < 0)
273                 return irq;
274
275         ret = devm_request_irq(&pdev->dev, irq, ftm_rtc_alarm_interrupt,
276                                0, dev_name(&pdev->dev), rtc);
277         if (ret < 0) {
278                 dev_err(&pdev->dev, "failed to request irq\n");
279                 return ret;
280         }
281
282         rtc->big_endian =
283                 device_property_read_bool(&pdev->dev, "big-endian");
284
285         rtc->alarm_freq = (u32)FIXED_FREQ_CLK / (u32)MAX_FREQ_DIV;
286         rtc->rtc_dev->ops = &ftm_rtc_ops;
287
288         device_init_wakeup(&pdev->dev, true);
289         ret = dev_pm_set_wake_irq(&pdev->dev, irq);
290         if (ret)
291                 dev_err(&pdev->dev, "failed to enable irq wake\n");
292
293         ret = rtc_register_device(rtc->rtc_dev);
294         if (ret) {
295                 dev_err(&pdev->dev, "can't register rtc device\n");
296                 return ret;
297         }
298
299         return 0;
300 }
301
302 static const struct of_device_id ftm_rtc_match[] = {
303         { .compatible = "fsl,ls1012a-ftm-alarm", },
304         { .compatible = "fsl,ls1021a-ftm-alarm", },
305         { .compatible = "fsl,ls1028a-ftm-alarm", },
306         { .compatible = "fsl,ls1043a-ftm-alarm", },
307         { .compatible = "fsl,ls1046a-ftm-alarm", },
308         { .compatible = "fsl,ls1088a-ftm-alarm", },
309         { .compatible = "fsl,ls208xa-ftm-alarm", },
310         { .compatible = "fsl,lx2160a-ftm-alarm", },
311         { },
312 };
313
314 static const struct acpi_device_id ftm_imx_acpi_ids[] = {
315         {"NXP0014",},
316         { }
317 };
318 MODULE_DEVICE_TABLE(acpi, ftm_imx_acpi_ids);
319
320 static struct platform_driver ftm_rtc_driver = {
321         .probe          = ftm_rtc_probe,
322         .driver         = {
323                 .name   = "ftm-alarm",
324                 .of_match_table = ftm_rtc_match,
325                 .acpi_match_table = ACPI_PTR(ftm_imx_acpi_ids),
326         },
327 };
328
329 static int __init ftm_alarm_init(void)
330 {
331         return platform_driver_register(&ftm_rtc_driver);
332 }
333
334 device_initcall(ftm_alarm_init);
335
336 MODULE_DESCRIPTION("NXP/Freescale FlexTimer alarm driver");