Merge remote-tracking branches 'asoc/topic/si476x', 'asoc/topic/simple', 'asoc/topic...
[linux-2.6-microblaze.git] / drivers / auxdisplay / Kconfig
1 # SPDX-License-Identifier: GPL-2.0
2 #
3 # For a description of the syntax of this configuration file,
4 # see Documentation/kbuild/kconfig-language.txt.
5 #
6 # Auxiliary display drivers configuration.
7 #
8
9 menuconfig AUXDISPLAY
10         bool "Auxiliary Display support"
11         ---help---
12           Say Y here to get to see options for auxiliary display drivers.
13           This option alone does not add any kernel code.
14
15           If you say N, all options in this submenu will be skipped and disabled.
16
17 config CHARLCD
18         tristate "Character LCD core support" if COMPILE_TEST
19
20 if AUXDISPLAY
21
22 config HD44780
23         tristate "HD44780 Character LCD support"
24         depends on GPIOLIB || COMPILE_TEST
25         select CHARLCD
26         ---help---
27           Enable support for Character LCDs using a HD44780 controller.
28           The LCD is accessible through the /dev/lcd char device (10, 156).
29           This code can either be compiled as a module, or linked into the
30           kernel and started at boot.
31           If you don't understand what all this is about, say N.
32
33 config KS0108
34         tristate "KS0108 LCD Controller"
35         depends on PARPORT_PC
36         default n
37         ---help---
38           If you have a LCD controlled by one or more KS0108
39           controllers, say Y. You will need also another more specific
40           driver for your LCD.
41
42           Depends on Parallel Port support. If you say Y at
43           parport, you will be able to compile this as a module (M)
44           and built-in as well (Y).
45
46           To compile this as a module, choose M here:
47           the module will be called ks0108.
48
49           If unsure, say N.
50
51 config KS0108_PORT
52         hex "Parallel port where the LCD is connected"
53         depends on KS0108
54         default 0x378
55         ---help---
56           The address of the parallel port where the LCD is connected.
57
58           The first  standard parallel port address is 0x378.
59           The second standard parallel port address is 0x278.
60           The third  standard parallel port address is 0x3BC.
61
62           You can specify a different address if you need.
63
64           If you don't know what I'm talking about, load the parport module,
65           and execute "dmesg" or "cat /proc/ioports". You can see there how
66           many parallel ports are present and which address each one has.
67
68           Usually you only need to use 0x378.
69
70           If you compile this as a module, you can still override this
71           using the module parameters.
72
73 config KS0108_DELAY
74         int "Delay between each control writing (microseconds)"
75         depends on KS0108
76         default "2"
77         ---help---
78           Amount of time the ks0108 should wait between each control write
79           to the parallel port.
80
81           If your LCD seems to miss random writings, increment this.
82
83           If you don't know what I'm talking about, ignore it.
84
85           If you compile this as a module, you can still override this
86           value using the module parameters.
87
88 config CFAG12864B
89         tristate "CFAG12864B LCD"
90         depends on X86
91         depends on FB
92         depends on KS0108
93         select FB_SYS_FILLRECT
94         select FB_SYS_COPYAREA
95         select FB_SYS_IMAGEBLIT
96         select FB_SYS_FOPS
97         default n
98         ---help---
99           If you have a Crystalfontz 128x64 2-color LCD, cfag12864b Series,
100           say Y. You also need the ks0108 LCD Controller driver.
101
102           For help about how to wire your LCD to the parallel port,
103           check Documentation/auxdisplay/cfag12864b
104
105           Depends on the x86 arch and the framebuffer support.
106
107           The LCD framebuffer driver can be attached to a console.
108           It will work fine. However, you can't attach it to the fbdev driver
109           of the xorg server.
110
111           To compile this as a module, choose M here:
112           the modules will be called cfag12864b and cfag12864bfb.
113
114           If unsure, say N.
115
116 config CFAG12864B_RATE
117        int "Refresh rate (hertz)"
118         depends on CFAG12864B
119         default "20"
120         ---help---
121           Refresh rate of the LCD.
122
123           As the LCD is not memory mapped, the driver has to make the work by
124           software. This means you should be careful setting this value higher.
125           If your CPUs are really slow or you feel the system is slowed down,
126           decrease the value.
127
128           Be careful modifying this value to a very high value:
129           You can freeze the computer, or the LCD maybe can't draw as fast as you
130           are requesting.
131
132           If you don't know what I'm talking about, ignore it.
133
134           If you compile this as a module, you can still override this
135           value using the module parameters.
136
137 config IMG_ASCII_LCD
138         tristate "Imagination Technologies ASCII LCD Display"
139         depends on HAS_IOMEM
140         default y if MIPS_MALTA || MIPS_SEAD3
141         select SYSCON
142         help
143           Enable this to support the simple ASCII LCD displays found on
144           development boards such as the MIPS Boston, MIPS Malta & MIPS SEAD3
145           from Imagination Technologies.
146
147 config HT16K33
148         tristate "Holtek Ht16K33 LED controller with keyscan"
149         depends on FB && OF && I2C && INPUT
150         select FB_SYS_FOPS
151         select FB_SYS_FILLRECT
152         select FB_SYS_COPYAREA
153         select FB_SYS_IMAGEBLIT
154         select INPUT_MATRIXKMAP
155         select FB_BACKLIGHT
156         help
157           Say yes here to add support for Holtek HT16K33, RAM mapping 16*8
158           LED controller driver with keyscan.
159
160 endif # AUXDISPLAY
161
162 config ARM_CHARLCD
163         bool "ARM Ltd. Character LCD Driver"
164         depends on PLAT_VERSATILE
165         help
166           This is a driver for the character LCD found on the ARM Ltd.
167           Versatile and RealView Platform Baseboards. It doesn't do
168           very much more than display the text "ARM Linux" on the first
169           line and the Linux version on the second line, but that's
170           still useful.
171
172 config PANEL
173         tristate "Parallel port LCD/Keypad Panel support"
174         depends on PARPORT
175         select CHARLCD
176         ---help---
177           Say Y here if you have an HD44780 or KS-0074 LCD connected to your
178           parallel port. This driver also features 4 and 6-key keypads. The LCD
179           is accessible through the /dev/lcd char device (10, 156), and the
180           keypad through /dev/keypad (10, 185). This code can either be
181           compiled as a module, or linked into the kernel and started at boot.
182           If you don't understand what all this is about, say N.
183
184 if PANEL
185
186 config PANEL_PARPORT
187         int "Default parallel port number (0=LPT1)"
188         range 0 255
189         default "0"
190         ---help---
191           This is the index of the parallel port the panel is connected to. One
192           driver instance only supports one parallel port, so if your keypad
193           and LCD are connected to two separate ports, you have to start two
194           modules with different arguments. Numbering starts with '0' for LPT1,
195           and so on.
196
197 config PANEL_PROFILE
198         int "Default panel profile (0-5, 0=custom)"
199         range 0 5
200         default "5"
201         ---help---
202           To ease configuration, the driver supports different configuration
203           profiles for past and recent wirings. These profiles can also be
204           used to define an approximative configuration, completed by a few
205           other options. Here are the profiles :
206
207             0 = custom (see further)
208             1 = 2x16 parallel LCD, old keypad
209             2 = 2x16 serial LCD (KS-0074), new keypad
210             3 = 2x16 parallel LCD (Hantronix), no keypad
211             4 = 2x16 parallel LCD (Nexcom NSA1045) with Nexcom's keypad
212             5 = 2x40 parallel LCD (old one), with old keypad
213
214           Custom configurations allow you to define how your display is
215           wired to the parallel port, and how it works. This is only intended
216           for experts.
217
218 config PANEL_KEYPAD
219         depends on PANEL_PROFILE="0"
220         int "Keypad type (0=none, 1=old 6 keys, 2=new 6 keys, 3=Nexcom 4 keys)"
221         range 0 3
222         default 0
223         ---help---
224           This enables and configures a keypad connected to the parallel port.
225           The keys will be read from character device 10,185. Valid values are :
226
227             0 : do not enable this driver
228             1 : old 6 keys keypad
229             2 : new 6 keys keypad, as used on the server at www.ant-computing.com
230             3 : Nexcom NSA1045's 4 keys keypad
231
232           New profiles can be described in the driver source. The driver also
233           supports simultaneous keys pressed when the keypad supports them.
234
235 config PANEL_LCD
236         depends on PANEL_PROFILE="0"
237         int "LCD type (0=none, 1=custom, 2=old //, 3=ks0074, 4=hantronix, 5=Nexcom)"
238         range 0 5
239         default 0
240         ---help---
241            This enables and configures an LCD connected to the parallel port.
242            The driver includes an interpreter for escape codes starting with
243            '\e[L' which are specific to the LCD, and a few ANSI codes. The
244            driver will be registered as character device 10,156, usually
245            under the name '/dev/lcd'. There are a total of 6 supported types :
246
247              0 : do not enable the driver
248              1 : custom configuration and wiring (see further)
249              2 : 2x16 & 2x40 parallel LCD (old wiring)
250              3 : 2x16 serial LCD (KS-0074 based)
251              4 : 2x16 parallel LCD (Hantronix wiring)
252              5 : 2x16 parallel LCD (Nexcom wiring)
253
254            When type '1' is specified, other options will appear to configure
255            more precise aspects (wiring, dimensions, protocol, ...). Please note
256            that those values changed from the 2.4 driver for better consistency.
257
258 config PANEL_LCD_HEIGHT
259         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
260         int "Number of lines on the LCD (1-2)"
261         range 1 2
262         default 2
263         ---help---
264           This is the number of visible character lines on the LCD in custom profile.
265           It can either be 1 or 2.
266
267 config PANEL_LCD_WIDTH
268         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
269         int "Number of characters per line on the LCD (1-40)"
270         range 1 40
271         default 40
272         ---help---
273           This is the number of characters per line on the LCD in custom profile.
274           Common values are 16,20,24,40.
275
276 config PANEL_LCD_BWIDTH
277         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
278         int "Internal LCD line width (1-40, 40 by default)"
279         range 1 40
280         default 40
281         ---help---
282           Most LCDs use a standard controller which supports hardware lines of 40
283           characters, although sometimes only 16, 20 or 24 of them are really wired
284           to the terminal. This results in some non-visible but addressable characters,
285           and is the case for most parallel LCDs. Other LCDs, and some serial ones,
286           however, use the same line width internally as what is visible. The KS0074
287           for example, uses 16 characters per line for 16 visible characters per line.
288
289           This option lets you configure the value used by your LCD in 'custom' profile.
290           If you don't know, put '40' here.
291
292 config PANEL_LCD_HWIDTH
293         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
294         int "Hardware LCD line width (1-64, 64 by default)"
295         range 1 64
296         default 64
297         ---help---
298           Most LCDs use a single address bit to differentiate line 0 and line 1. Since
299           some of them need to be able to address 40 chars with the lower bits, they
300           often use the immediately superior power of 2, which is 64, to address the
301           next line.
302
303           If you don't know what your LCD uses, in doubt let 16 here for a 2x16, and
304           64 here for a 2x40.
305
306 config PANEL_LCD_CHARSET
307         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
308         int "LCD character set (0=normal, 1=KS0074)"
309         range 0 1
310         default 0
311         ---help---
312           Some controllers such as the KS0074 use a somewhat strange character set
313           where many symbols are at unusual places. The driver knows how to map
314           'standard' ASCII characters to the character sets used by these controllers.
315           Valid values are :
316
317              0 : normal (untranslated) character set
318              1 : KS0074 character set
319
320           If you don't know, use the normal one (0).
321
322 config PANEL_LCD_PROTO
323         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
324         int "LCD communication mode (0=parallel 8 bits, 1=serial)"
325         range 0 1
326         default 0
327         ---help---
328           This driver now supports any serial or parallel LCD wired to a parallel
329           port. But before assigning signals, the driver needs to know if it will
330           be driving a serial LCD or a parallel one. Serial LCDs only use 2 wires
331           (SDA/SCL), while parallel ones use 2 or 3 wires for the control signals
332           (E, RS, sometimes RW), and 4 or 8 for the data. Use 0 here for a 8 bits
333           parallel LCD, and 1 for a serial LCD.
334
335 config PANEL_LCD_PIN_E
336         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO="0"
337         int "Parallel port pin number & polarity connected to the LCD E signal (-17...17) "
338         range -17 17
339         default 14
340         ---help---
341           This describes the number of the parallel port pin to which the LCD 'E'
342           signal has been connected. It can be :
343
344                   0 : no connection (eg: connected to ground)
345               1..17 : directly connected to any of these pins on the DB25 plug
346             -1..-17 : connected to the same pin through an inverter (eg: transistor).
347
348           Default for the 'E' pin in custom profile is '14' (AUTOFEED).
349
350 config PANEL_LCD_PIN_RS
351         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO="0"
352         int "Parallel port pin number & polarity connected to the LCD RS signal (-17...17) "
353         range -17 17
354         default 17
355         ---help---
356           This describes the number of the parallel port pin to which the LCD 'RS'
357           signal has been connected. It can be :
358
359                   0 : no connection (eg: connected to ground)
360               1..17 : directly connected to any of these pins on the DB25 plug
361             -1..-17 : connected to the same pin through an inverter (eg: transistor).
362
363           Default for the 'RS' pin in custom profile is '17' (SELECT IN).
364
365 config PANEL_LCD_PIN_RW
366         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO="0"
367         int "Parallel port pin number & polarity connected to the LCD RW signal (-17...17) "
368         range -17 17
369         default 16
370         ---help---
371           This describes the number of the parallel port pin to which the LCD 'RW'
372           signal has been connected. It can be :
373
374                   0 : no connection (eg: connected to ground)
375               1..17 : directly connected to any of these pins on the DB25 plug
376             -1..-17 : connected to the same pin through an inverter (eg: transistor).
377
378           Default for the 'RW' pin in custom profile is '16' (INIT).
379
380 config PANEL_LCD_PIN_SCL
381         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO!="0"
382         int "Parallel port pin number & polarity connected to the LCD SCL signal (-17...17) "
383         range -17 17
384         default 1
385         ---help---
386           This describes the number of the parallel port pin to which the serial
387           LCD 'SCL' signal has been connected. It can be :
388
389                   0 : no connection (eg: connected to ground)
390               1..17 : directly connected to any of these pins on the DB25 plug
391             -1..-17 : connected to the same pin through an inverter (eg: transistor).
392
393           Default for the 'SCL' pin in custom profile is '1' (STROBE).
394
395 config PANEL_LCD_PIN_SDA
396         depends on PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO!="0"
397         int "Parallel port pin number & polarity connected to the LCD SDA signal (-17...17) "
398         range -17 17
399         default 2
400         ---help---
401           This describes the number of the parallel port pin to which the serial
402           LCD 'SDA' signal has been connected. It can be :
403
404                   0 : no connection (eg: connected to ground)
405               1..17 : directly connected to any of these pins on the DB25 plug
406             -1..-17 : connected to the same pin through an inverter (eg: transistor).
407
408           Default for the 'SDA' pin in custom profile is '2' (D0).
409
410 config PANEL_LCD_PIN_BL
411         depends on PANEL_PROFILE="0" && PANEL_LCD="1"
412         int "Parallel port pin number & polarity connected to the LCD backlight signal (-17...17) "
413         range -17 17
414         default 0
415         ---help---
416           This describes the number of the parallel port pin to which the LCD 'BL' signal
417           has been connected. It can be :
418
419                   0 : no connection (eg: connected to ground)
420               1..17 : directly connected to any of these pins on the DB25 plug
421             -1..-17 : connected to the same pin through an inverter (eg: transistor).
422
423           Default for the 'BL' pin in custom profile is '0' (uncontrolled).
424
425 config PANEL_CHANGE_MESSAGE
426         bool "Change LCD initialization message ?"
427         default "n"
428         ---help---
429           This allows you to replace the boot message indicating the kernel version
430           and the driver version with a custom message. This is useful on appliances
431           where a simple 'Starting system' message can be enough to stop a customer
432           from worrying.
433
434           If you say 'Y' here, you'll be able to choose a message yourself. Otherwise,
435           say 'N' and keep the default message with the version.
436
437 config PANEL_BOOT_MESSAGE
438         depends on PANEL_CHANGE_MESSAGE="y"
439         string "New initialization message"
440         default ""
441         ---help---
442           This allows you to replace the boot message indicating the kernel version
443           and the driver version with a custom message. This is useful on appliances
444           where a simple 'Starting system' message can be enough to stop a customer
445           from worrying.
446
447           An empty message will only clear the display at driver init time. Any other
448           printf()-formatted message is valid with newline and escape codes.