6 * Analog Devices ADM1022
10 Addresses scanned: I2C 0x2c - 0x2e
12 Datasheet: http://www.analog.com/en/prod/0,2877,ADM1022,00.html
14 * Texas Instruments THMC50
18 Addresses scanned: I2C 0x2c - 0x2e
20 Datasheet: https://www.ti.com/
23 Author: Krzysztof Helt <krzysztof.h1@wp.pl>
25 This driver was derived from the 2.4 kernel thmc50.c source file.
29 thmc50.c (2.4 kernel):
31 - Frodo Looijaard <frodol@dds.nl>
32 - Philip Edelbrock <phil@netroedge.com>
37 * adm1022_temp3: short array
38 List of adapter,address pairs to force chips into ADM1022 mode with
39 second remote temperature. This does not work for original THMC50 chips.
44 The THMC50 implements: an internal temperature sensor, support for an
45 external diode-type temperature sensor (compatible w/ the diode sensor inside
46 many processors), and a controllable fan/analog_out DAC. For the temperature
47 sensors, limits can be set through the appropriate Overtemperature Shutdown
48 register and Hysteresis register. Each value can be set and read to half-degree
49 accuracy. An alarm is issued (usually to a connected LM78) when the
50 temperature gets higher then the Overtemperature Shutdown value; it stays on
51 until the temperature falls below the Hysteresis value. All temperatures are in
52 degrees Celsius, and are guaranteed within a range of -55 to +125 degrees.
54 The THMC50 only updates its values each 1.5 seconds; reading it more often
55 will do no harm, but will return 'old' values.
57 The THMC50 is usually used in combination with LM78-like chips, to measure
58 the temperature of the processor(s).
60 The ADM1022 works the same as THMC50 but it is faster (5 Hz instead of
61 1 Hz for THMC50). It can be also put in a new mode to handle additional
62 remote temperature sensor. The driver use the mode set by BIOS by default.
64 In case the BIOS is broken and the mode is set incorrectly, you can force
65 the mode with additional remote temperature with adm1022_temp3 parameter.
66 A typical symptom of wrong setting is a fan forced to full speed.
71 The driver provides up to three temperatures:
78 - 2nd remote only for ADM1022
81 - fan speed (0 = stop, 255 = full)
85 The value of 0 for pwm1 also forces FAN_OFF signal from the chip,
86 so it stops fans even if the value 0 into the ANALOG_OUT register does not.
88 The driver was tested on Compaq AP550 with two ADM1022 chips (one works
89 in the temp3 mode), five temperature readings and two fans.