Merge remote-tracking branch 'kumar/next' into next
[linux-2.6-microblaze.git] / Documentation / hwmon / max34440
1 Kernel driver max34440
2 ======================
3
4 Supported chips:
5   * Maxim MAX34440
6     Prefixes: 'max34440'
7     Addresses scanned: -
8     Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34440.pdf
9   * Maxim MAX34441
10     PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller
11     Prefixes: 'max34441'
12     Addresses scanned: -
13     Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf
14   * Maxim MAX34446
15     PMBus Power-Supply Data Logger
16     Prefixes: 'max34446'
17     Addresses scanned: -
18     Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34446.pdf
19   * Maxim MAX34460
20     PMBus 12-Channel Voltage Monitor & Sequencer
21     Prefix: 'max34460'
22     Addresses scanned: -
23     Datasheet: http://datasheets.maximintegrated.com/en/ds/MAX34460.pdf
24   * Maxim MAX34461
25     PMBus 16-Channel Voltage Monitor & Sequencer
26     Prefix: 'max34461'
27     Addresses scanned: -
28     Datasheet: http://datasheets.maximintegrated.com/en/ds/MAX34461.pdf
29
30 Author: Guenter Roeck <linux@roeck-us.net>
31
32
33 Description
34 -----------
35
36 This driver supports hardware montoring for Maxim MAX34440 PMBus 6-Channel
37 Power-Supply Manager, MAX34441 PMBus 5-Channel Power-Supply Manager
38 and Intelligent Fan Controller, and MAX34446 PMBus Power-Supply Data Logger.
39 It also supports the MAX34460 and MAX34461 PMBus Voltage Monitor & Sequencers.
40 The MAX34460 supports 12 voltage channels, and the MAX34461 supports 16 voltage
41 channels.
42
43 The driver is a client driver to the core PMBus driver. Please see
44 Documentation/hwmon/pmbus for details on PMBus client drivers.
45
46
47 Usage Notes
48 -----------
49
50 This driver does not auto-detect devices. You will have to instantiate the
51 devices explicitly. Please see Documentation/i2c/instantiating-devices for
52 details.
53
54 For MAX34446, the value of the currX_crit attribute determines if current or
55 voltage measurement is enabled for a given channel. Voltage measurement is
56 enabled if currX_crit is set to 0; current measurement is enabled if the
57 attribute is set to a positive value. Power measurement is only enabled if
58 channel 1 (3) is configured for voltage measurement, and channel 2 (4) is
59 configured for current measurement.
60
61
62 Platform data support
63 ---------------------
64
65 The driver supports standard PMBus driver platform data.
66
67
68 Sysfs entries
69 -------------
70
71 The following attributes are supported. Limits are read-write; all other
72 attributes are read-only.
73
74 in[1-6]_label           "vout[1-6]".
75 in[1-6]_input           Measured voltage. From READ_VOUT register.
76 in[1-6]_min             Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
77 in[1-6]_max             Maximum voltage. From VOUT_OV_WARN_LIMIT register.
78 in[1-6]_lcrit           Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
79 in[1-6]_crit            Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
80 in[1-6]_min_alarm       Voltage low alarm. From VOLTAGE_UV_WARNING status.
81 in[1-6]_max_alarm       Voltage high alarm. From VOLTAGE_OV_WARNING status.
82 in[1-6]_lcrit_alarm     Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
83 in[1-6]_crit_alarm      Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
84 in[1-6]_lowest          Historical minimum voltage.
85 in[1-6]_highest         Historical maximum voltage.
86 in[1-6]_reset_history   Write any value to reset history.
87
88                         MAX34446 only supports in[1-4].
89
90 curr[1-6]_label         "iout[1-6]".
91 curr[1-6]_input         Measured current. From READ_IOUT register.
92 curr[1-6]_max           Maximum current. From IOUT_OC_WARN_LIMIT register.
93 curr[1-6]_crit          Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
94 curr[1-6]_max_alarm     Current high alarm. From IOUT_OC_WARNING status.
95 curr[1-6]_crit_alarm    Current critical high alarm. From IOUT_OC_FAULT status.
96 curr[1-4]_average       Historical average current (MAX34446 only).
97 curr[1-6]_highest       Historical maximum current.
98 curr[1-6]_reset_history Write any value to reset history.
99
100                         in6 and curr6 attributes only exist for MAX34440.
101                         MAX34446 only supports curr[1-4].
102
103 power[1,3]_label        "pout[1,3]"
104 power[1,3]_input        Measured power.
105 power[1,3]_average      Historical average power.
106 power[1,3]_highest      Historical maximum power.
107
108                         Power attributes only exist for MAX34446.
109
110 temp[1-8]_input         Measured temperatures. From READ_TEMPERATURE_1 register.
111                         temp1 is the chip's internal temperature. temp2..temp5
112                         are remote I2C temperature sensors. For MAX34441, temp6
113                         is a remote thermal-diode sensor. For MAX34440, temp6..8
114                         are remote I2C temperature sensors.
115 temp[1-8]_max           Maximum temperature. From OT_WARN_LIMIT register.
116 temp[1-8]_crit          Critical high temperature. From OT_FAULT_LIMIT register.
117 temp[1-8]_max_alarm     Temperature high alarm.
118 temp[1-8]_crit_alarm    Temperature critical high alarm.
119 temp[1-8]_average       Historical average temperature (MAX34446 only).
120 temp[1-8]_highest       Historical maximum temperature.
121 temp[1-8]_reset_history Write any value to reset history.
122
123                         temp7 and temp8 attributes only exist for MAX34440.
124                         MAX34446 only supports temp[1-3].
125