1 Kernel driver ltc4261
2 =====================
3
4 Supported chips:
5
6   * Linear Technology LTC4261
7
8     Prefix: 'ltc4261'
9
10     Addresses scanned: -
11
12     Datasheet:
13
14         http://cds.linear.com/docs/Datasheet/42612fb.pdf
15
16 Author: Guenter Roeck <linux@roeck-us.net>
17
18
19 Description
20 -----------
21
22 The LTC4261/LTC4261-2 negative voltage Hot Swap controllers allow a board
23 to be safely inserted and removed from a live backplane.
24
25
26 Usage Notes
27 -----------
28
29 This driver does not probe for LTC4261 devices, since there is no register
30 which can be safely used to identify the chip. You will have to instantiate
31 the devices explicitly.
32
33 Example: the following will load the driver for an LTC4261 at address 0x10
34 on I2C bus #1::
35
36         $ modprobe ltc4261
37         $ echo ltc4261 0x10 > /sys/bus/i2c/devices/i2c-1/new_device
38
39
40 Sysfs entries
41 -------------
42
43 Voltage readings provided by this driver are reported as obtained from the ADC
44 registers. If a set of voltage divider resistors is installed, calculate the
45 real voltage by multiplying the reported value with (R1+R2)/R2, where R1 is the
46 value of the divider resistor against the measured voltage and R2 is the value
47 of the divider resistor against Ground.
48
49 Current reading provided by this driver is reported as obtained from the ADC
50 Current Sense register. The reported value assumes that a 1 mOhm sense resistor
51 is installed. If a different sense resistor is installed, calculate the real
52 current by dividing the reported value by the sense resistor value in mOhm.
53
54 The chip has two voltage sensors, but only one set of voltage alarm status bits.
55 In many many designs, those alarms are associated with the ADIN2 sensor, due to
56 the proximity of the ADIN2 pin to the OV pin. ADIN2 is, however, not available
57 on all chip variants. To ensure that the alarm condition is reported to the user,
58 report it with both voltage sensors.
59
60 ======================= =============================
61 in1_input               ADIN2 voltage (mV)
62 in1_min_alarm           ADIN/ADIN2 Undervoltage alarm
63 in1_max_alarm           ADIN/ADIN2 Overvoltage alarm
64
65 in2_input               ADIN voltage (mV)
66 in2_min_alarm           ADIN/ADIN2 Undervoltage alarm
67 in2_max_alarm           ADIN/ADIN2 Overvoltage alarm
68
69 curr1_input             SENSE current (mA)
70 curr1_alarm             SENSE overcurrent alarm
71 ======================= =============================